問題
It deals with the quantitative analysis and accurate measurement of the chemical composition of the analytes in the human body in order to help the physician understand the health status, obtain a diagnosis and develop a treatment plan.
問題
It combines analytics and intrumentation with information technology
問題
It encompasses varied chemical testing that plays a significant role in the detection, diagnosis and treatment of diseases as well as monitoring and maintaining patient health.
問題
Found virtually at all hospitals which operates 24hrs a day, 7 days a week to provide the essential most requested test.
問題
With highly automated environment and instruments with multi-analyte capabilities
問題
Types of analytical techniques found on multianalyte analysis
問題
Based with colorimec detection
問題
Designed with a membrane that is specific for a particular analyte (Na, K, Cl). Change in potential is measured when electrodes are placed in a sample.
問題
There are less frequently ordered tests, labor intensive and often manual methods.
問題
•Non-stat test (result not required immediately) •Employs ELECTROPHORESIS, HPLC, INFRARED SPECTROSCOPY, RADIOIMMUNOASSAY (RIA), GC-MS
Intro to Clinical Chemistry
得点
0 / 10
正答率
0%
正解: 0
不正解: 0
未解答: 10
問題一覧
1
It deals with the quantitative analysis and accurate measurement of the chemical composition of the analytes in the human body in order to help the physician understand the health status, obtain a diagnosis and develop a treatment plan.Clinical chemistry
2
It combines analytics and intrumentation with information technologyClinical chemistry
3
It encompasses varied chemical testing that plays a significant role in the detection, diagnosis and treatment of diseases as well as monitoring and maintaining patient health.Clinical chemistry
4
Found virtually at all hospitals which operates 24hrs a day, 7 days a week to provide the essential most requested test.Core lab facility
5
With highly automated environment and instruments with multi-analyte capabilitiesCore lab facility
6
Types of analytical techniques found on multianalyte analysisImmunoassays, Ion-selective electrodes
7
Based with colorimec detectionImmunoassays
8
Designed with a membrane that is specific for a particular analyte (Na, K, Cl). Change in potential is measured when electrodes are placed in a sample.Ion-selective electrodes
9
There are less frequently ordered tests, labor intensive and often manual methods.Special chemistry
10
•Non-stat test (result not required immediately) •Employs ELECTROPHORESIS, HPLC, INFRARED SPECTROSCOPY, RADIOIMMUNOASSAY (RIA), GC-MSSpecial chemistry
11
A test where the result is not required immediatelyNon-stat test
12
•more expensive •CCU, ER, ICU OR SATELLITE CENTRE (clinic)Point of care testing
13
•Test are urgent importance •Bedside on in clinical care unitPoint of care testing
14
What kind of water is unsuitable for lab use?Tap water
15
Types of Water Purification TechniquesDistillation, Reverse osmosis, Ultrafiltration, Deionization
16
Removes most organic matter during the water purification.Distillation
17
Removes organic, ionic, microbial and viral contaminants during the water purificationReverse osmosis
18
Removes particulate matter, bacteria and emusified solids during the water purificationUltrafiltration
19
Ions removed during the water purificationDeionization
20
Reagent Grades of WaterType I, Type II, Type III, CAP
21
Grade of water required for sensitive testType I
22
Grade of water which is acceptable for most usesType II
23
Grade of water which is OK for washing glasswaresType III
24
Refers to Quality control of water, pH, electrical resistance and bacterial cultureCAP
25
The unit of measurement for LengthMeter
26
The unit of measurement for MassGram
27
The unit of measurement for QuantityMole
28
The unit of measurement for volumeLiter
29
The unit of measurement for TimeSecond
30
What is the solvent that is measured the most in the clinical lab?Plasma
31
True/False: The clinical lab always uses solutionsTrue
32
Type YES afterwardsYES
33
It refers to whatever the substance we want to measureSolute
34
True or False: The substance in a solution are in chemical combination with one another.False
35
3 components of MolalityGram weight of solute, Solute’s gram molecular weight, Solvent quantity
36
Analyze then type YES if done! How many grams of NaOH are needed to make a 25.0% w/w solution using deionized water as the solvent? SOLUTION: 25.0% w/w = X g of solute in 100 g of solution X = 25.0g NaOHYES
37
Most accurate method of expressing concentration but can be cumbersome (especially with liquid), not often used in clinical labs.% w/w
38
Easiest & commonly used, very accurate if temperature controlled.% w/v
39
Analyze then type YES if done! What is the % w/v of a solution that has 15.0g of NaCl dissolved into a total volume of 100ml deionized water? X % w/v = 15%YES
40
Least accurate, but used when both substances are liquids.% v/v
41
Analyze then type YES if done! How many milliliters of ethanol are needed to make a 75.0% v/v solution using deionized water as the solvent? 75.0% v/v EtOH = X ml EtOH in 100ml of solution = 75.0ml EtOHYES
42
Moles/literMolarity
43
moles/1000grams solventMolality
44
equivalent weight/literNormality
45
An example of this are borosilicate glass with low alkali content such as kimax and pyrex.High thermal resistant glass
46
They are strengthen chemically rather than thermally, six times stronger than borosilicayeAlumina-silicate glass
47
Glass which has been strengthened chemicallyCorex brand
48
Recommended for use involving high temperature ; drastic heat shock. It is primarily used in ashing and ignition techniques.Vycor brand
49
Non-volumetric glasswareBeaker, Flask
50
Volumetric GlasswareVolumetric flask, Graduated cylinder
51
Laboratory equiment used to transport a measured volume of liquidPipettes
52
A pippete which is designed to deliver a single volume precisely.Volumetric flask
53
Pippetes which are available for measuring very small volumesMicropippetes
54
They are neither calibrated nor graduated and are considered fairly innacurate today.Pasteur pippetes
55
This pippete dispenses a pre-rated sample when plunger is moved through its complete stroke.Automated pippetes
56
Types of pippetesVolumetric pippetes, Graduated pippetes, Pasteur pippetes, Micropipettes, Automated pippetes
57
Used for transferring liquid to another container or to transfer a small amount of reagent for use in procedures.Beaker
58
For rapid measurement of liquid volumeGraduated cylinder
59
Features a conical base, a cylinder neck and a flat bottom and is NOT used for ACCURATE measurementErlenmeyer flask
60
It separate solids from a liquid suspension by means of centrifugal force.Centrifuge
61
Most common type of Balance in the laboratorySingle pan
62
Plastic wares in the labPolyolefins, Polycarbonate resins, Tygon, Teflon Fluorocarbon resins
63
Cleansing solutions for glasswareDiluted detergent, 10% KOH, Potassium dichromate
64
With highly automated environment, and equiped with equipments with Multi-analyte capabilitiesCore lab facility
65
A modified volumetric pipette with their bulbs closer to the delivery tipOstwald-Folin pipette
66
It is a type of volumetric pipettes constructed of thickwalled capillary tubing with a bulb in the center and one mark above and one belowVan Slyke pipette
67
Types of volumetric pipetteOstwald-Folin pipette, Van slyke pipette
68
This is a soda-lime glass composed of micture of silicone, calcium and sodiumStandard flint glass
69
This contains materials that imparts an amber or red color to the glass and reduce thr amount of light passing to the substance within the glasswareLow actinic glassware
70
A pipette marker TC and sometimes called "drain out pipette". it have a single painted or frosted ring at the top.Mohr
71
A pippet marked TC and also known as a "blown out pipette". It has no base mark and graduated continue onto the tipSerological