暗記メーカー
ログイン
mockboard 2019
  • Hannah Angelique Losaria

  • 問題数 65 • 4/26/2024

    記憶度

    完璧

    9

    覚えた

    24

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    In the microbial assay of antibiotics, the microorganism used for pen g is?

    s aureus

  • 2

    Bottles, vials, caps, packer boxes. Which is not a primary packaging component

    packer boxes

  • 3

    Drug substances that are withheld from distribution until batch certification from FDA has been received

    antibiotics

  • 4

    Content uniformity is to be performed for all tablets whose active ingredients are:

    50mg or less

  • 5

    The presence of cotton fiber in a liquid preparation is considered as an/an

    ocular defect

  • 6

    In infrared spectrometry, water is not used as solvent because water will:

    absorb IR radiation, dissolve the NaCl cell holder

  • 7

    The law related to spectrometry wherein the power of transmitted light decreases exponentially as the THICKNESS of the solution INCREASES ARITHMETICALLY is:

    lambert's/ bouger's

  • 8

    The power of transmitted radiant beam DECREASES exponentially as the CONCENTRATION of the solution containing the absorption species increases arithmetically

    beer's

  • 9

    In the spectrophotometry procedure for assay, aside from the sample of unknown, this is also required

    reference

  • 10

    Formation of gas, formation of precipitate, formation of soluble products, formation of slightly ionized substances. Which condition DOES NOT cause a reaction to go to completion?

    formation of soluble products

  • 11

    A plot of absorbance against CONCENTRATION of a standard drawn in a straight line is

    beer's

  • 12

    The indicator used in the assay of a weak acid reactung with a strong base is

    phenolphthalein TS

  • 13

    Strong acid, strong base indicator

    phenolphthalein

  • 14

    Strong acid, weak base indicator

    methyl red

  • 15

    Strong base, weak acid indicator

    phenolphthalein

  • 16

    Weak acid, weak base indicator

    none

  • 17

    The method of assay of vitamin b12 and calcium pantothenate is

    microbial-turbidimetric method

  • 18

    Measure of excess energy loss by emission

    fluorometry

  • 19

    Example of fluorometry

    thiamine, riboflavin

  • 20

    Measure of TRANSMITTED light

    turbidity

  • 21

    Example of turbidity

    antibiotics, ca pantothenate, vit b12

  • 22

    Measure REFLECTED light

    nephelometry

  • 23

    An excellent solvent for fats and fatty oils used in the determination of extractive content of a plant sample

    water

  • 24

    Temperature equivalent to dull red heat

    800-1000°c

  • 25

    Addition of an excess titrant to permit complete reaction of the analyte with the titrant and then titrating the unreacted excess titrant with another standard solution

    residual titration

  • 26

    Analyte is reacted with titrant after rendering it soluble in the titration medium

    direct titration

  • 27

    Analyte undergoes preliminary treatment prior to titration

    indirect titration

  • 28

    Appropriate solvent for extraction of RESINS

    ethanol

  • 29

    It is a property of liquids tgat is closely related to the RESISTANCE TO FLOW

    viscosity

  • 30

    This raw material quality control test entails addition of silver nitrate to a hydrochloric acid standard

    limit test for chlorides

  • 31

    This raw material quality control test entails addition of barium chloride to a sulfuric axid standard

    limit test for sulfates

  • 32

    Passage of a fluid or solution through a sterilizing grade membrane to produce a sterile effluent

    sterilization by filtration

  • 33

    Paddle over disk is also known as

    apparatus 5

  • 34

    Basket is apparatus number

    1

  • 35

    Paddle is apparatus number

    2

  • 36

    Reciprocating cylinder is also known as apparatus number

    3

  • 37

    Flow through cell is apparatus numer

    4

  • 38

    Revolving cylinder is apparatus number

    6

  • 39

    Reciprocating holder is apparatus number

    7

  • 40

    Buccal tablets should disintegrate within

    4 hours

  • 41

    The radiant energy requiredin the analysis of drugs using fluorometry

    IR

  • 42

    Immediate release tablets/capsules

    within 30 mins in water

  • 43

    Buccal tablets

    within 4 hours in water

  • 44

    Sublingual tablets

    2-3 minutes in water

  • 45

    Enteric coated in water

    5 mins

  • 46

    Enteric coated in gastric fluid

    1 hour

  • 47

    Usp method 1 for iodine value

    hanus

  • 48

    Hanus

    12 and br2

  • 49

    Method 2 in iodine value

    wijs

  • 50

    Wijs

    12 monochloride

  • 51

    Method 3

    hubl

  • 52

    Hubl

    unofficial method

  • 53

    The operating speed for paddle in dissolution apparatus is

    50rpm

  • 54

    Content uniformity test used to ensure which of the following quality in tablet products

    potency

  • 55

    Class if raw materials, which are to be subjected in tests and assays by the qc department and are still WAITING the final disposition of the qc department

    quarantined products

  • 56

    The theoritical point at which equivalent amounts of analyte and titrant have reacted us called

    stochiometric/ equivalence point

  • 57

    Buret, pipet, grad. cylinder, vokumetric flask. Which is the LEAST accurate

    pipet

  • 58

    High efficiency particulate air (hepa) is an example of

    filter

  • 59

    Endpoint assay of SODIUM NITRATE

    light pink

  • 60

    Far IR

    15-300

  • 61

    Medium IR

    3-15

  • 62

    Near IR

    780-3000

  • 63

    Visible IR

    380-780

  • 64

    UV

    200-380

  • 65

    Section of qc responsible for validating existing and tentative procedures of testing

    specifications and analytical lab