Question
Limit stops shall be adjusted to deliver hot water with a maximum temperature of _______.
Question
1 Kcal is how many BTU?
Question
What is the allowed depth of shower dam or threshold?
Question
Minimum pipe sizing for a branch serving a 400 DFU.
Question
Clotheswashers in groups of 3 or more shall be rated at ___________ each for the common horiontal and vertical waste pipe sizing.
Question
Trap arm size of a service sink
Question
A large opening in a sewer line or part of a plumbing system constructed with sufficient size for a man to gain access therein for maintenance purposes
Question
An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding ________.
Question
When a Public or Private Sewer is not available for use, excreta drainage piping from buildings and premises shall be connected to an approved ________.
Question
Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than ________.
Weekly Test 2
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
Limit stops shall be adjusted to deliver hot water with a maximum temperature of _______.120 F
2
1 Kcal is how many BTU?3.965
3
What is the allowed depth of shower dam or threshold?2”-9”
4
Minimum pipe sizing for a branch serving a 400 DFU.127 mm
5
Clotheswashers in groups of 3 or more shall be rated at ___________ each for the common horiontal and vertical waste pipe sizing.6 FU
6
Trap arm size of a service sink51 mm
7
A large opening in a sewer line or part of a plumbing system constructed with sufficient size for a man to gain access therein for maintenance purposesmanhole
8
An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding ________.135 deg
9
When a Public or Private Sewer is not available for use, excreta drainage piping from buildings and premises shall be connected to an approved ________.Private Sewage Disposal System
10
Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than ________.1033 kPa
11
Potable water shall use solders and fluxes with a lead content not exceeding _______.0.2%
12
Preferred pipe for transporting gasBlack Steel Pipe
13
WSFU of a private hose bibb3
14
Medical gas piping is most often joined by _______.Silver Brazing
15
Which of the following fixture group qualifies the definition of battery of fixtures?5 water closets
16
A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____________.Bathub
17
What is the maximum Fixture unit loading of a 2" trap?4
18
AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the __________ with the critical level not less than ___________ above flood level rim.last valve; 152 mm
19
1 Water Closet and 1 Urinal must be provided for temporary workingmen facilities for each ________ workmen.30
20
Linings for showers shall not be nailed or perforated at any point less than _______ above the finished dam or threshold.1”
21
How many fixture units if equivalent to a 30 gpm-rated sump?60 FU
22
A valve opened and closed by the fall and rise, respectively, of an attached ball floating on the surface of the liquid.Ball Cock
23
Building Sewer or other drainage pipings must be installed not less than _________ within any building or structure.0.6 m
24
What is the maximum fixture loading of a 8" pipe sloped at 1%?2112
25
What is the Maximum DFU loading of a 102 mm horizontal branch?216
26
A standpipe having a remote control device at each hose station.Manually-Operated Standpipe System
27
A double check valve backflow preventer requires __________ minimum clearance at the bottom for maintenance.305 mm
28
Thickness of Continuous waste and fixture tailpiece- seamless drawn brassGauge 20 (0.8 mm)
29
Water Closet provision for 300 females in Assembly Places for Public Use11
30
Threads per inch for pipe size of 13 mm diameter.14
31
Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least ________ larger than the _________ inlet.2 pipe sizes; largest side inlet
32
The public sewer may be considered not being available when a sewer is located more than _________ from any proposed building or exterior drainage facility.61 m
33
Consists of a body, a checking member, and an atmospheric opening.Atmospheric Vacuum Breaker
34
A _________ diameter circular basin shall be equivalent to 1 lavatory.457.2 mm
35
A pressure regulator must be installed if the local water service pressure is above _________.80 psi
36
A device installed in a drainage system to prevent reverse flow.Backwater Valve
37
Threads per inch of a 64 mm cleanout size8
38
Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _________ of mercury.0 to 63.5 cm
39
Galvanized wrought iron or galvanized steel pipe shall be kept __________________.150 mm above ground
40
Copper tubing shall be fully externally protected with a/an ________________ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.bitumastic coating
41
Color of Steam Division- High Pressure PipeWhite
42
1 Laundry Tray must be provided per _____ persons.50
43
Each tailpiece, continuous waste or waste and overflow shall not be less than ______ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.38 mm O.D.
44
Which of the following can be drained through an air break?evaporative cooler
45
(ANSI) Pipe Color code for Fire QuenchingRed with White Lettering
46
Code on Sanitation of the PhilippinesPD 856
47
Hanger rod size for 5" pipe size13 mm
48
Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _______.Bitumen
49
Backflow prevention device for a hose bibbAtmospheric Vacuum Breaker
50
The transference of heat by the upward movement of a warm light air current.Convection