Question
What is the DFU of a private water closet?
Question
The water pressure to be used for water piping tests
Question
For flush tank supplies, the available pressure may not be less than ________.
Question
A plumbing permit shall become null and void if the plumbing work is not commenced within _________ from the date of such permit.
Question
Sewage or other waste from a plumbing system which may be deleterious to the surface or sub-surface waters shall not be discharged into the ground or into any waterway unless first rendered innocuous through subjection to some acceptable form of treatment.
Question
The level in a fixture at which water begins to overflow over the top ring of the fixture.
Question
A term applied to those portions of a plumbing system, which have been installed and approved prior to contemplated additions, alterations, or correction, is called
Question
This consists of a pliable rubber cup and handle, and is capable of creating both a positive pressure (by forcing the cup down), and a negative pressure (vacuum) when pulled away from the fixture. Variations on the design are typically limited to the size of the cup and length of the handle.
Question
A beginner at the trade who usually serves for 3 to 5 years as a helper to a journeyman.A beginner at the trade who usually serves for 3 to 5 years as a helper to a journeyman.
Question
Who is the overall chairman in-charge on the Revision & Upgrading of the National Plumbing Code of the Philippines?
MPLE
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
What is the DFU of a private water closet?4
2
The water pressure to be used for water piping tests150% working pressure
3
For flush tank supplies, the available pressure may not be less than ________.55.16 kPa
4
A plumbing permit shall become null and void if the plumbing work is not commenced within _________ from the date of such permit.1 year
5
Sewage or other waste from a plumbing system which may be deleterious to the surface or sub-surface waters shall not be discharged into the ground or into any waterway unless first rendered innocuous through subjection to some acceptable form of treatment.Principle #22
6
The level in a fixture at which water begins to overflow over the top ring of the fixture.Flood level
7
A term applied to those portions of a plumbing system, which have been installed and approved prior to contemplated additions, alterations, or correction, is calledExisting work
8
This consists of a pliable rubber cup and handle, and is capable of creating both a positive pressure (by forcing the cup down), and a negative pressure (vacuum) when pulled away from the fixture. Variations on the design are typically limited to the size of the cup and length of the handle.Plunger
9
A beginner at the trade who usually serves for 3 to 5 years as a helper to a journeyman.A beginner at the trade who usually serves for 3 to 5 years as a helper to a journeyman.Apprentice Plumber
10
Who is the overall chairman in-charge on the Revision & Upgrading of the National Plumbing Code of the Philippines?Engr. Camilet
11
What Section of the RA 1378 refers to the qualifications of the applicants for registration and examination for Master Plumber?Section 12
12
In _______, the Board of Examiners for Master Plumbers and the NAMPAP prepared a curriculum for plumbing engineering.1966-1969
13
How many years has the plumbing code been in existence since its promulgation before it has been amended?40 years
14
A permit is not required for repair that involve only ________.the working parts of faucet and valves
15
How many sets of approved plans, specifications, computations, and related data shall be retained by the Administrative Authority?1
16
This pipe is also known as Terracotta Pipe.Vitrified Clay Pipe
17
This type of Cast Iron is recommended when the length of a pipe needed is more than 150 cm long.Single Hub
18
This pipe shall be supported at intervals not exceeding 1.20 m at centers with a rigid vertical back-up.Lead Pipe
19
A fitting with adjacent reverse bends and shaped like the letter "S"Double-Bend Fitting
20
The distance of water closet or bidet from center to side0.375 m
21
How many faucets are there in the Plumbing Unit according to the Revised National Plumbing Code?4
22
Which material ultimately seals a caulked or bell and spigot joint?Pig Lead
23
Shall be responsible for the maintenance of the plumbing systems.Owner or owner’s agent
24
A system of collection, transportation, treatment, and disposal of sewage is called __________.Sewage disposal system
25
Any branch in a building drain other than the primary branch.Secondary Branch
26
Minimum air pressure of air test ______ kPa34.5
27
The NAMPAP president who spearheaded the update of the Revised National Plumbing Code.Jaime M. Cabase
28
A Backflow Prevention device that consists of a body, a checking member and an atmospheric opening.AVB
29
Plumbing Law of the Philippines was signed by Pres. Ramon Magsaysay on _________.June 18, 1955
30
Type of pump used to distribute water within a building or residence, when an upfeed system cannot provide adequate pressure to supply fixtures with potable water. Pump that increases low water pressure and flow. ___________.Booster Pump
31
What is the vent pipe system in Plumbing which liquid waste can flow through?Wet Vent
32
It is the discharge from any fixture, appliance or appurtenance in connection with a plumbing system which does not receive fecal matter.Liquid Waste
33
A pipe which makes an angle of more than 45 degrees from the horizontal is considered ________.vertical
34
1 gpm = ________ L/s0.0631
35
Maximum height of water closet for the handicapped and disabled (BP344)0.45 m
36
How many female office employees are suited for 5 lavatories?200
37
Building sewers shall be tested by completely filling the sewer line with water from the lowest tothe highest point
38
Maximum number of fixtures to be served by a grease trap4
39
What is a vent connecting one or more individual vents with a stack vent or vent stack.branch
40
Horizontal distance of vertical vent pipes for outdoor installations to any part of the roof that is used for other purposes.3.00 m
41
Where can a cleanout be located?all of these