Question
A Master Plumber shall live up to the standards of the professional practice of plumbing.
Question
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.
Question
This examination subject in Master Plumbing was originally split into two.
Question
What is the standard length of Galvanized Iron Pipe?
Question
The birth of the plumbing profession in the Philippines is traced back to the ___ century.
Question
What is NOT included in a plumbing unit?
Question
The Plumbing Code has been in existence for almost _____ since its promulgation before it has been amended.
Question
Which is not a proper connection for HDPE pipes?
Question
Depth of the molten pig lead in a caulked joint
Question
Minimum weight of a lead for flashing or vent terminals
WT 1
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
A Master Plumber shall live up to the standards of the professional practice of plumbing.Article III, Section 3 of Code of Ethics
2
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.Wye
3
This examination subject in Master Plumbing was originally split into two.Practical Problems
4
What is the standard length of Galvanized Iron Pipe?6 m
5
The birth of the plumbing profession in the Philippines is traced back to the ___ century.17th
6
What is NOT included in a plumbing unit?Urinal
7
The Plumbing Code has been in existence for almost _____ since its promulgation before it has been amended.40 years
8
Which is not a proper connection for HDPE pipes?solvent cement
9
Depth of the molten pig lead in a caulked joint25.4 mm
10
Minimum weight of a lead for flashing or vent terminals14.63 kg per sqm
11
Preferred when a piece of pipe needed is shorter than 150 cm longDouble Hub
12
A water heater is classified as?Plumbing Appliance
13
Color for Type M copper pipeRed
14
Distance of bottom of all pipe tranches to the footing of any adjacent building or structure parallel to it45 degrees
15
Each fixture directly connected to the drainage system shall be equipped with a _____.water-sealed trap
16
Tube made of plastic material and colored black. The crosssectional shape is normally oval and is denoted by its outside diameter or 0.D.Polybutylene
17
A set of moral principles or values to govern the conduct of an individual belonging to a group or profession on the basis of honestly, fairness, and justice.Ethics
18
1 fixture unit is equal to?7.48 gallons per minute
19
An open return bend usually made up of two 90° bendsReturn bend
20
Every building where _____ shall have a sewer service connection to a public or private sewer systems.plumbing fixtures are installed
21
Roughing-in of cold and hot water supply line are ideally distanced at least _____ apart.8"
22
What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?Decrease in DFU loading
23
A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____.120 days
24
Each member of the board, shall at the time of his appointment be at least _____ of age.30
25
An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread.Slip Joint
26
The Administrative Authority must be notified at least ___ working days before such inspection is intended.3
27
Any pipe or fitting installed at an angle of more than 45 degrees with the vertical line.horizontal pipe
28
Which authority is responsible for the administration and enforcement of the National Plumbing Code?Plumbing Official
29
The top edge of a receptacle from where water overflows.Flood Level Rim
30
Elastomeric gasketed and rubber-ring joints shall comply with _____ installation standardIAPMO
31
ASTM means?American Society for Testing and Materials
32
For caulked-on closet ring, the minimum overall depth shall be:2"
33
Wiped lead joints shall have an exposed surface on each side of a joint not less than _____.19 mm
34
The year when NAMPAP was organized and registered with the Securities and Exchange Commission1935
35
All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application.6
36
What is the accreditation number of NAMPAP?14
37
Code on Sanitation of the PhilippinesPD 856
38
Common maximum service temperature rating of PVC140 deg. F
39
The following are grounds for non-issuance of the certificate of registration by the Board of Master Plumbers except for _____.failure to pay the required fees
40
Vertical support of _____ is placed not less than every other storey height.Screwed Pipe
41
Plumbing fixtures shall be made of smooth non-absorbent material, free from concealed fouling surfaces and shall be located in ventilated enclosuresPrinciple No. 7
42
Trap arm size of Laundry Tub38 mm
43
IPS shall be supported at ___ intervals for piping 19 mm diameter and smaller.3 m
44
A pipe flange that is not drilled for bolt holes.blank flange
45
Integrated within an air accumulator vessel which is designed to discharge a predetermined quantity of water into fixtures for flushing purposesFlushometer Tank
46
The Old Fire Code of the PhilippinesPD 1185
47
A pipe or conduit for carrying sewage and wastewater .Sewer
48
Who is the current chairman of the Board of Examiners for Master Plumber?Reynald B. Ilagan
49
(ANSI) Pipe Color code for Fire QuenchingRed with White Lettering
50
Any change, addition or modification in construction or occupancyAlteration