    As an experienced registered master plumber, what will be the ideal size of the P-trap that should be installed underground or embedded on a concrete slab?

    100mm

  • 2

    A 100 mm & 3.0 m plastic pipe is used to install in house drainage. The face-to. face distance is 4.40 meters. The engagement length is 45 mm and the solvent cement per joint requires is 16 g. What is the amount of solvent in grams?

    32

  • 3

    What condition must be satisfied for the water supply in building?

    Fast removal of the waste with a minimum probability of leakage and stoppage of drain

  • 4

    Each fixture in the plumbing system represents a certain demand for water, what Is the water demand of the wall hydrant?

    8 gpm

  • 5

    Each fixture in the plumbing system represents a certain demand for water, what is the water demand of the bathtub faucet?

    4 gpm

  • 6

    Each fixture in the plumbing system represents a certain demand for water, what is the water demänd of a shower head?

    4 gpm

  • 7

    Each fixture in the plumbing system represents a certain demand for water, what is the water demand of the sink faucet?

    3 gpm

  • 8

    Each fixture in the plumbing system represents a certain demand for water, what is the water demand of the drinking fountain?

    3/4

  • 9

    What is the name of that piece of pipe less than 12 inches in the length threaded on both sides?

    Nipple

  • 10

    What do you call that short pipe whose thread at both ends meet?

    Close nipple

  • 11

    What do you call that pipe whose thread at both ends leaves a small amount of space?

    Short pipe

  • 12

    What is the minimum nominal diameter of a water service line pipe which wm provide the building with water requirements during peak

    3/4 inch

  • 13

    What is the tin content in a brass fitting?

    5%

  • 14

    What is the zinc content in a brass fitting?

    5%

  • 15

    What is the copper content in a brass fitting?

    85%

  • 16

    A 25 mm diameter water pipe can carry water equivalent to how many 12 mm diameter water pipe?

    4

  • 17

    The recommended fall per foot for a 4 in pipe and larger due to impractical depth is ____.

    1/8 in per foot

  • 18

    The recommended fall per foot for a 3 in pipe and larger is ___.

    1/4 in per foot

  • 19

    In roughing-in for lavatory that is to have an 1-½ in drain, the distance between the fixture trap and the vent is not more than ___.

    3’-0”

  • 20

    What is the maximum depth of trench for subsurface drain tile where the soil is to satisfactory absorption?

    2’-1”

  • 21

    Each fixture in the plumbing system represents a certain demand for water. What is the water demand of the water closet tank ballcock?

    3 gpm

  • 22

    Which type of fire line installation has become obsolete and is seldom used?

    Dry standpipe

  • 23

    Generally, what is the standard diameter of the standpipe for buildings two or three stories in height?

    4 in.

  • 24

    Generally, what is the standard diameter of the standpipe for buildings more than six stories in height?Generally, what is the standard diameter of the standpipe for buildings more than six stories in height?

    6 in.

  • 25

    Why is a wet standpipe with Siamese connection considered most practical?

    It is being served by the domestic water supply under constant pressure.

  • 26

    What is the disadvantage of the wet standpipe with Siamese connection?

    The danger of contamination of the building water supply from the unknown source.

  • 27

    What is the most practical method of repairing or correcting leak of a plastic pipe?

    Cut and insert coupling

  • 28

    Careful installation of the water supply distribution is essential. Which statement differs among the group?

    Short offset and unnecessary fittings

  • 29

    Damage to property leaking points, trapped piping and water hammer in a water system are attributed to ___.

    Poor workmanship

  • 30

    In what ways must the water distribution system be suspended from the basement ceiling in large concrete buildings?

    Iron inserted on the tough floor sheating and slushed into the concrete slab

  • 31

    What is that it is not good practice to use a gate valve on a lawn sprinkler?

    It will fail to close tightly.

  • 32

    Why must basement water supply must be properly graded and aligned?

    It is convenient to provide a drum valve to make it possible to drain the entire water system.

  • 33

    Where should gate valve be used?

    In between the main supply line and pump line.

  • 34

    What is the recommended distance above the flood level rim of a unit for a vacuum breaker to be installed?

    6 in.

  • 35

    In what instances that a mechanical drainage will be used?

    Drainage cannot be affected by gravity.

  • 36

    What kind of pipe usually used as leaders in tall buildings?

    Wrought iron pipe.

  • 37

    What will be the best kind of pipe for underground drains within the buildings?

    Cast iropn pipe

  • 38

    The drainage system in the building should be designed, constructed and maintained as to guard against fouling, deposits of solids and clogging. What feature should be provided to make maintenance efficient and effective?

    Adequate cleanouts

  • 39

    Why is rainwater leaders are often not included as part of the sanitary drainage system?

    Excessive rainwater hinders the treatment of the sewage.

  • 40

    Which word does not apply to the plumbing system?

    Smoke tight

  • 41

    If a plumbing plan scaled as 1:10,000, then 10 cm * 20 cm catchment area in the plan is equal to ___m^3 of rainfall in actual for every hour? Assume 100mm/hr rain intensity

    200,000m^3

  • 42

    What is the shape for the signage for the signage for women's comfort room; order to aid visually impaited women readily determine whether a washroom is for men or women?

    Circle

  • 43

    A fire sprinkler head has a k-factor of 7.6. What is the flow rate at 15 psi?

    29.4

  • 44

    All valves controlling the supply of a fire sprinkler system should be:

    Indicating

  • 45

    Where practical, all pipes from fixtures shall be run in what direction with respect to the nearest wall or building line?

    Parallel

  • 46

    By regulation, the minimum design pressure in distribution system is?

    30 psi

  • 47

    Are there major difference between sewer and septic system in your home?

    None of the above

  • 48

    Minimum height if Shower head.

    1.78m

  • 49

    What is the number one reason why pumps cavitate?

    Low pressure

  • 50

    What is the lead content in a brass fitting.

    5%

  • YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 1ヶ月前

    YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    100問 • 1ヶ月前
    ユーザ名非公開

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 1ヶ月前

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    100問 • 1ヶ月前
    ユーザ名非公開

    Project Engineer YT 1

    Project Engineer YT 1

    ユーザ名非公開 · 100問 · 1ヶ月前

    Project Engineer YT 1

    Project Engineer YT 1

    100問 • 1ヶ月前
    ユーザ名非公開

    Project Engineer EXAM

    Project Engineer EXAM

    ユーザ名非公開 · 62問 · 1ヶ月前

    Project Engineer EXAM

    Project Engineer EXAM

    62問 • 1ヶ月前
    ユーザ名非公開

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    ユーザ名非公開 · 100問 · 1ヶ月前

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    100問 • 1ヶ月前
    ユーザ名非公開

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    ユーザ名非公開 · 100問 · 1ヶ月前

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    100問 • 1ヶ月前
    ユーザ名非公開

    July 2023 PE Refresher

    July 2023 PE Refresher

    ユーザ名非公開 · 70問 · 1ヶ月前

    July 2023 PE Refresher

    July 2023 PE Refresher

    70問 • 1ヶ月前
    ユーザ名非公開

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    ユーザ名非公開 · 93問 · 1ヶ月前

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    93問 • 1ヶ月前
    ユーザ名非公開

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    ユーザ名非公開 · 86問 · 1ヶ月前

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    86問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 4

    Plumbing Code 4

    ユーザ名非公開 · 100問 · 1ヶ月前

    Plumbing Code 4

    Plumbing Code 4

    100問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 5

    Plumbing Code 5

    ユーザ名非公開 · 100問 · 1ヶ月前

    Plumbing Code 5

    Plumbing Code 5

    100問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 6

    Plumbing Code 6

    ユーザ名非公開 · 100問 · 1ヶ月前

    Plumbing Code 6

    Plumbing Code 6

    100問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 7

    Plumbing Code 7

    ユーザ名非公開 · 100問 · 1ヶ月前

    Plumbing Code 7

    Plumbing Code 7

    100問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 8

    Plumbing Code 8

    ユーザ名非公開 · 100問 · 1ヶ月前

    Plumbing Code 8

    Plumbing Code 8

    100問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 3

    Plumbing Code 3

    ユーザ名非公開 · 100問 · 1ヶ月前

    Plumbing Code 3

    Plumbing Code 3

    100問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    ユーザ名非公開 · 97問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    97問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    ユーザ名非公開 · 99問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    99問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    ユーザ名非公開 · 96問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    96問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    ユーザ名非公開 · 95問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    95問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    ユーザ名非公開 · 97問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    97問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 7

    Sanitation, Plumbing Design, and Installation 7

    ユーザ名非公開 · 100問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 7

    Sanitation, Plumbing Design, and Installation 7

    100問 • 1ヶ月前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 8

    Sanitation, Plumbing Design, and Installation 8

    ユーザ名非公開 · 98問 · 1ヶ月前

    Sanitation, Plumbing Design, and Installation 8

    Sanitation, Plumbing Design, and Installation 8

    98問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Tools 1

    Plumbing Tools 1

    ユーザ名非公開 · 87問 · 1ヶ月前

    Plumbing Tools 1

    Plumbing Tools 1

    87問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Tools 2

    Plumbing Tools 2

    ユーザ名非公開 · 53問 · 1ヶ月前

    Plumbing Tools 2

    Plumbing Tools 2

    53問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems and Experiences 1

    Practical Problems and Experiences 1

    ユーザ名非公開 · 100問 · 1ヶ月前

    Practical Problems and Experiences 1

    Practical Problems and Experiences 1

    100問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems and Experiences 2

    Practical Problems and Experiences 2

    ユーザ名非公開 · 100問 · 1ヶ月前

    Practical Problems and Experiences 2

    Practical Problems and Experiences 2

    100問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems and Experiences 3

    Practical Problems and Experiences 3

    ユーザ名非公開 · 99問 · 1ヶ月前

    Practical Problems and Experiences 3

    Practical Problems and Experiences 3

    99問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems and Experiences 4

    Practical Problems and Experiences 4

    ユーザ名非公開 · 100問 · 1ヶ月前

    Practical Problems and Experiences 4

    Practical Problems and Experiences 4

    100問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic Terms 1

    Plumbing Arithmetic Terms 1

    ユーザ名非公開 · 49問 · 1ヶ月前

    Plumbing Arithmetic Terms 1

    Plumbing Arithmetic Terms 1

    49問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic Terms 2

    Plumbing Arithmetic Terms 2

    ユーザ名非公開 · 47問 · 1ヶ月前

    Plumbing Arithmetic Terms 2

    Plumbing Arithmetic Terms 2

    47問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic Terms 3

    Plumbing Arithmetic Terms 3

    ユーザ名非公開 · 49問 · 1ヶ月前

    Plumbing Arithmetic Terms 3

    Plumbing Arithmetic Terms 3

    49問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic Terms 4

    Plumbing Arithmetic Terms 4

    ユーザ名非公開 · 27問 · 1ヶ月前

    Plumbing Arithmetic Terms 4

    Plumbing Arithmetic Terms 4

    27問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code WSFU

    Plumbing Code WSFU

    ユーザ名非公開 · 58問 · 1ヶ月前

    Plumbing Code WSFU

    Plumbing Code WSFU

    58問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems and Experiences REFRESHER 1

    Practical Problems and Experiences REFRESHER 1

    ユーザ名非公開 · 100問 · 1ヶ月前

    Practical Problems and Experiences REFRESHER 1

    Practical Problems and Experiences REFRESHER 1

    100問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems and Experiences REFRESHER 2

    Practical Problems and Experiences REFRESHER 2

    ユーザ名非公開 · 70問 · 1ヶ月前

    Practical Problems and Experiences REFRESHER 2

    Practical Problems and Experiences REFRESHER 2

    70問 • 1ヶ月前
    ユーザ名非公開

    Item # and Descriptions

    Item # and Descriptions

    ユーザ名非公開 · 24問 · 1ヶ月前

    Item # and Descriptions

    Item # and Descriptions

    24問 • 1ヶ月前
    ユーザ名非公開

    Item 200 Aggregate Subbase Course

    Item 200 Aggregate Subbase Course

    ユーザ名非公開 · 16問 · 1ヶ月前

    Item 200 Aggregate Subbase Course

    Item 200 Aggregate Subbase Course

    16問 • 1ヶ月前
    ユーザ名非公開

    Item 201 Aggregate Base Course

    Item 201 Aggregate Base Course

    ユーザ名非公開 · 16問 · 1ヶ月前

    Item 201 Aggregate Base Course

    Item 201 Aggregate Base Course

    16問 • 1ヶ月前
    ユーザ名非公開

    Item 202 Crushed Aggregate Base Course

    Item 202 Crushed Aggregate Base Course

    ユーザ名非公開 · 18問 · 1ヶ月前

    Item 202 Crushed Aggregate Base Course

    Item 202 Crushed Aggregate Base Course

    18問 • 1ヶ月前
    ユーザ名非公開

    Item 203 Lime Stabilized Road Mix Base Course

    Item 203 Lime Stabilized Road Mix Base Course

    ユーザ名非公開 · 27問 · 1ヶ月前

    Item 203 Lime Stabilized Road Mix Base Course

    Item 203 Lime Stabilized Road Mix Base Course

    27問 • 1ヶ月前
    ユーザ名非公開

    Item 204 Portland Cement Stabilized Road Mix Base Course

    Item 204 Portland Cement Stabilized Road Mix Base Course

    ユーザ名非公開 · 7問 · 1ヶ月前

    Item 204 Portland Cement Stabilized Road Mix Base Course

    Item 204 Portland Cement Stabilized Road Mix Base Course

    7問 • 1ヶ月前
    ユーザ名非公開

    Item 207 Portland Cement Stabilized Treated Plant Mix Base Course

    Item 207 Portland Cement Stabilized Treated Plant Mix Base Course

    ユーザ名非公開 · 13問 · 1ヶ月前

    Item 207 Portland Cement Stabilized Treated Plant Mix Base Course

    Item 207 Portland Cement Stabilized Treated Plant Mix Base Course

    13問 • 1ヶ月前
    ユーザ名非公開

    Item 205 Asphalt Stabilized Road Mix Base Course

    Item 205 Asphalt Stabilized Road Mix Base Course

    ユーザ名非公開 · 7問 · 1ヶ月前

    Item 205 Asphalt Stabilized Road Mix Base Course

    Item 205 Asphalt Stabilized Road Mix Base Course

    7問 • 1ヶ月前
    ユーザ名非公開

    Item 206 Chemically Stabilized Road Mix Subbase/Base Course

    Item 206 Chemically Stabilized Road Mix Subbase/Base Course

    ユーザ名非公開 · 11問 · 1ヶ月前

    Item 206 Chemically Stabilized Road Mix Subbase/Base Course

    Item 206 Chemically Stabilized Road Mix Subbase/Base Course

    11問 • 1ヶ月前
    ユーザ名非公開

    Item 300 Aggregate Surface Course

    Item 300 Aggregate Surface Course

    ユーザ名非公開 · 11問 · 1ヶ月前

    Item 300 Aggregate Surface Course

    Item 300 Aggregate Surface Course

    11問 • 1ヶ月前
    ユーザ名非公開

    Item 301 Bituminous Prime Coat

    Item 301 Bituminous Prime Coat

    ユーザ名非公開 · 10問 · 1ヶ月前

    Item 301 Bituminous Prime Coat

    Item 301 Bituminous Prime Coat

    10問 • 1ヶ月前
    ユーザ名非公開

    Item 303 Bituminous Seal Coat

    Item 303 Bituminous Seal Coat

    ユーザ名非公開 · 20問 · 1ヶ月前

    Item 303 Bituminous Seal Coat

    Item 303 Bituminous Seal Coat

    20問 • 1ヶ月前
    ユーザ名非公開

    RNPCP Chapter 6 to 9

    RNPCP Chapter 6 to 9

    ユーザ名非公開 · 94問 · 1ヶ月前

    RNPCP Chapter 6 to 9

    RNPCP Chapter 6 to 9

    94問 • 1ヶ月前
    ユーザ名非公開

    RNPCP Chapter 10 to 13

    RNPCP Chapter 10 to 13

    ユーザ名非公開 · 93問 · 1ヶ月前

    RNPCP Chapter 10 to 13

    RNPCP Chapter 10 to 13

    93問 • 1ヶ月前
    ユーザ名非公開

    RNPCP Appendix A and B

    RNPCP Appendix A and B

    ユーザ名非公開 · 79問 · 1ヶ月前

    RNPCP Appendix A and B

    RNPCP Appendix A and B

    79問 • 1ヶ月前
    ユーザ名非公開

    Republic Acts

    Republic Acts

    ユーザ名非公開 · 9問 · 1ヶ月前

    Republic Acts

    Republic Acts

    9問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic Terms 5

    Plumbing Arithmetic Terms 5

    ユーザ名非公開 · 68問 · 1ヶ月前

    Plumbing Arithmetic Terms 5

    Plumbing Arithmetic Terms 5

    68問 • 1ヶ月前
    ユーザ名非公開

    Principles and Code of Ethics

    Principles and Code of Ethics

    ユーザ名非公開 · 29問 · 1ヶ月前

    Principles and Code of Ethics

    Principles and Code of Ethics

    29問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic Problems 1

    Plumbing Arithmetic Problems 1

    ユーザ名非公開 · 75問 · 1ヶ月前

    Plumbing Arithmetic Problems 1

    Plumbing Arithmetic Problems 1

    75問 • 1ヶ月前
    ユーザ名非公開

    Item 406 Prestressed Concrete Structures

    Item 406 Prestressed Concrete Structures

    ユーザ名非公開 · 36問 · 1ヶ月前

    Item 406 Prestressed Concrete Structures

    Item 406 Prestressed Concrete Structures

    36問 • 1ヶ月前
    ユーザ名非公開

    Item 405 Structural Concrete

    Item 405 Structural Concrete

    ユーザ名非公開 · 41問 · 1ヶ月前

    Item 405 Structural Concrete

    Item 405 Structural Concrete

    41問 • 1ヶ月前
    ユーザ名非公開

    Item 400 Piling

    Item 400 Piling

    ユーザ名非公開 · 80問 · 1ヶ月前

    Item 400 Piling

    Item 400 Piling

    80問 • 1ヶ月前
    ユーザ名非公開

    Item 311 Portland Cement Concrete Pavement (PART 2)

    Item 311 Portland Cement Concrete Pavement (PART 2)

    ユーザ名非公開 · 61問 · 1ヶ月前

    Item 311 Portland Cement Concrete Pavement (PART 2)

    Item 311 Portland Cement Concrete Pavement (PART 2)

    61問 • 1ヶ月前
    ユーザ名非公開

    Item 311 Portland Cement Concrete Pavement (PART 1)

    Item 311 Portland Cement Concrete Pavement (PART 1)

    ユーザ名非公開 · 78問 · 1ヶ月前

    Item 311 Portland Cement Concrete Pavement (PART 1)

    Item 311 Portland Cement Concrete Pavement (PART 1)

    78問 • 1ヶ月前
    ユーザ名非公開

    Standpipe Requirements

    Standpipe Requirements

    ユーザ名非公開 · 29問 · 1ヶ月前

    Standpipe Requirements

    Standpipe Requirements

    29問 • 1ヶ月前
    ユーザ名非公開

    Spdi 1

    Spdi 1

    ユーザ名非公開 · 100問 · 1ヶ月前

    Spdi 1

    Spdi 1

    100問 • 1ヶ月前
    ユーザ名非公開

    Spdi 2

    Spdi 2

    ユーザ名非公開 · 98問 · 1ヶ月前

    Spdi 2

    Spdi 2

    98問 • 1ヶ月前
    ユーザ名非公開

    SPI version D pt 2

    SPI version D pt 2

    ユーザ名非公開 · 61問 · 1ヶ月前

    SPI version D pt 2

    SPI version D pt 2

    61問 • 1ヶ月前
    ユーザ名非公開

    plumbing code

    plumbing code

    ユーザ名非公開 · 100問 · 1ヶ月前

    plumbing code

    plumbing code

    100問 • 1ヶ月前
    ユーザ名非公開

    plumbing code 2

    plumbing code 2

    ユーザ名非公開 · 100問 · 1ヶ月前

    plumbing code 2

    plumbing code 2

    100問 • 1ヶ月前
    ユーザ名非公開

    plumbing code 3

    plumbing code 3

    ユーザ名非公開 · 56問 · 1ヶ月前

    plumbing code 3

    plumbing code 3

    56問 • 1ヶ月前
    ユーザ名非公開

    Practice Problem

    Practice Problem

    ユーザ名非公開 · 70問 · 1ヶ月前

    Practice Problem

    Practice Problem

    70問 • 1ヶ月前
    ユーザ名非公開

    PP pre

    PP pre

    ユーザ名非公開 · 100問 · 1ヶ月前

    PP pre

    PP pre

    100問 • 1ヶ月前
    ユーザ名非公開

    PP Pre 2

    PP Pre 2

    ユーザ名非公開 · 100問 · 1ヶ月前

    PP Pre 2

    PP Pre 2

    100問 • 1ヶ月前
    ユーザ名非公開

    PP pre 3

    PP pre 3

    ユーザ名非公開 · 44問 · 1ヶ月前

    PP pre 3

    PP pre 3

    44問 • 1ヶ月前
    ユーザ名非公開

    WT 1

    WT 1

    ユーザ名非公開 · 50問 · 1ヶ月前

    WT 1

    WT 1

    50問 • 1ヶ月前
    ユーザ名非公開

    WT 2

    WT 2

    ユーザ名非公開 · 48問 · 1ヶ月前

    WT 2

    WT 2

    48問 • 1ヶ月前
    ユーザ名非公開

    WT 3

    WT 3

    ユーザ名非公開 · 50問 · 1ヶ月前

    WT 3

    WT 3

    50問 • 1ヶ月前
    ユーザ名非公開

    WT 6

    WT 6

    ユーザ名非公開 · 50問 · 1ヶ月前

    WT 6

    WT 6

    50問 • 1ヶ月前
    ユーザ名非公開

    Definition of Terms 1

    Definition of Terms 1

    ユーザ名非公開 · 90問 · 1ヶ月前

    Definition of Terms 1

    Definition of Terms 1

    90問 • 1ヶ月前
    ユーザ名非公開

    Definition of Terms 2

    Definition of Terms 2

    ユーザ名非公開 · 90問 · 1ヶ月前

    Definition of Terms 2

    Definition of Terms 2

    90問 • 1ヶ月前
    ユーザ名非公開

    Definition of Terms 3

    Definition of Terms 3

    ユーザ名非公開 · 90問 · 1ヶ月前

    Definition of Terms 3

    Definition of Terms 3

    90問 • 1ヶ月前
    ユーザ名非公開

    Refresher SPDI 1

    Refresher SPDI 1

    ユーザ名非公開 · 100問 · 1ヶ月前

    Refresher SPDI 1

    Refresher SPDI 1

    100問 • 1ヶ月前
    ユーザ名非公開

    Refresher SPDI 1

    Refresher SPDI 1

    ユーザ名非公開 · 9問 · 1ヶ月前

    Refresher SPDI 1

    Refresher SPDI 1

    9問 • 1ヶ月前
    ユーザ名非公開

    Weekly Test 1

    Weekly Test 1

    ユーザ名非公開 · 50問 · 1ヶ月前

    Weekly Test 1

    Weekly Test 1

    50問 • 1ヶ月前
    ユーザ名非公開

    Weekly Test 2

    Weekly Test 2

    ユーザ名非公開 · 50問 · 1ヶ月前

    Weekly Test 2

    Weekly Test 2

    50問 • 1ヶ月前
    ユーザ名非公開

    Weekly Test 3

    Weekly Test 3

    ユーザ名非公開 · 50問 · 1ヶ月前

    Weekly Test 3

    Weekly Test 3

    50問 • 1ヶ月前
    ユーザ名非公開

    MPLE

    MPLE

    ユーザ名非公開 · 41問 · 1ヶ月前

    MPLE

    MPLE

    41問 • 1ヶ月前
    ユーザ名非公開

    CDG- Plumbing Code 1

    CDG- Plumbing Code 1

    ユーザ名非公開 · 48問 · 1ヶ月前

    CDG- Plumbing Code 1

    CDG- Plumbing Code 1

    48問 • 1ヶ月前
    ユーザ名非公開

    CDG- Plumbing Code 1.1

    CDG- Plumbing Code 1.1

    ユーザ名非公開 · 50問 · 1ヶ月前

    CDG- Plumbing Code 1.1

    CDG- Plumbing Code 1.1

    50問 • 1ヶ月前
    ユーザ名非公開

    CDG- Plumbing Code 1.4

    CDG- Plumbing Code 1.4

    ユーザ名非公開 · 23問 · 1ヶ月前

    CDG- Plumbing Code 1.4

    CDG- Plumbing Code 1.4

    23問 • 1ヶ月前
    ユーザ名非公開

    CDG- Plumbing Code 1.2

    CDG- Plumbing Code 1.2

    ユーザ名非公開 · 50問 · 1ヶ月前

    CDG- Plumbing Code 1.2

    CDG- Plumbing Code 1.2

    50問 • 1ヶ月前
    ユーザ名非公開

    CGD- Plumbing Code 1.3

    CGD- Plumbing Code 1.3

    ユーザ名非公開 · 50問 · 1ヶ月前

    CGD- Plumbing Code 1.3

    CGD- Plumbing Code 1.3

    50問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 1

    Plumbing Code 1

    ユーザ名非公開 · 50問 · 1ヶ月前

    Plumbing Code 1

    Plumbing Code 1

    50問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Code 1.1

    Plumbing Code 1.1

    ユーザ名非公開 · 22問 · 1ヶ月前

    Plumbing Code 1.1

    Plumbing Code 1.1

    22問 • 1ヶ月前
    ユーザ名非公開

    CGD - Sanitary Design

    CGD - Sanitary Design

    ユーザ名非公開 · 19問 · 1ヶ月前

    CGD - Sanitary Design

    CGD - Sanitary Design

    19問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems 1

    Practical Problems 1

    ユーザ名非公開 · 50問 · 1ヶ月前

    Practical Problems 1

    Practical Problems 1

    50問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems 1.1

    Practical Problems 1.1

    ユーザ名非公開 · 47問 · 1ヶ月前

    Practical Problems 1.1

    Practical Problems 1.1

    47問 • 1ヶ月前
    ユーザ名非公開

    Practical Problems 2

    Practical Problems 2

    ユーザ名非公開 · 50問 · 1ヶ月前

    Practical Problems 2

    Practical Problems 2

    50問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic 1

    Plumbing Arithmetic 1

    ユーザ名非公開 · 50問 · 1ヶ月前

    Plumbing Arithmetic 1

    Plumbing Arithmetic 1

    50問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic 1.1

    Plumbing Arithmetic 1.1

    ユーザ名非公開 · 50問 · 1ヶ月前

    Plumbing Arithmetic 1.1

    Plumbing Arithmetic 1.1

    50問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic 2

    Plumbing Arithmetic 2

    ユーザ名非公開 · 50問 · 1ヶ月前

    Plumbing Arithmetic 2

    Plumbing Arithmetic 2

    50問 • 1ヶ月前
    ユーザ名非公開

    Plumbing Arithmetic 2.1

    Plumbing Arithmetic 2.1

    ユーザ名非公開 · 50問 · 1ヶ月前

    Plumbing Arithmetic 2.1

    Plumbing Arithmetic 2.1

    50問 • 1ヶ月前
    ユーザ名非公開

    問題一覧

  • 1

    As an experienced registered master plumber, what will be the ideal size of the P-trap that should be installed underground or embedded on a concrete slab?

    100mm

  • 2

    A 100 mm & 3.0 m plastic pipe is used to install in house drainage. The face-to. face distance is 4.40 meters. The engagement length is 45 mm and the solvent cement per joint requires is 16 g. What is the amount of solvent in grams?

    32

  • 3

    What condition must be satisfied for the water supply in building?

    Fast removal of the waste with a minimum probability of leakage and stoppage of drain

  • 4

    Each fixture in the plumbing system represents a certain demand for water, what Is the water demand of the wall hydrant?

    8 gpm

  • 5

    Each fixture in the plumbing system represents a certain demand for water, what is the water demand of the bathtub faucet?

    4 gpm

  • 6

    Each fixture in the plumbing system represents a certain demand for water, what is the water demänd of a shower head?

    4 gpm

  • 7

    Each fixture in the plumbing system represents a certain demand for water, what is the water demand of the sink faucet?

    3 gpm

  • 8

    Each fixture in the plumbing system represents a certain demand for water, what is the water demand of the drinking fountain?

    3/4

  • 9

    What is the name of that piece of pipe less than 12 inches in the length threaded on both sides?

    Nipple

  • 10

    What do you call that short pipe whose thread at both ends meet?

    Close nipple

  • 11

    What do you call that pipe whose thread at both ends leaves a small amount of space?

    Short pipe

  • 12

    What is the minimum nominal diameter of a water service line pipe which wm provide the building with water requirements during peak

    3/4 inch

  • 13

    What is the tin content in a brass fitting?

    5%

  • 14

    What is the zinc content in a brass fitting?

    5%

  • 15

    What is the copper content in a brass fitting?

    85%

  • 16

    A 25 mm diameter water pipe can carry water equivalent to how many 12 mm diameter water pipe?

    4

  • 17

    The recommended fall per foot for a 4 in pipe and larger due to impractical depth is ____.

    1/8 in per foot

  • 18

    The recommended fall per foot for a 3 in pipe and larger is ___.

    1/4 in per foot

  • 19

    In roughing-in for lavatory that is to have an 1-½ in drain, the distance between the fixture trap and the vent is not more than ___.

    3’-0”

  • 20

    What is the maximum depth of trench for subsurface drain tile where the soil is to satisfactory absorption?

    2’-1”

  • 21

    Each fixture in the plumbing system represents a certain demand for water. What is the water demand of the water closet tank ballcock?

    3 gpm

  • 22

    Which type of fire line installation has become obsolete and is seldom used?

    Dry standpipe

  • 23

    Generally, what is the standard diameter of the standpipe for buildings two or three stories in height?

    4 in.

  • 24

    Generally, what is the standard diameter of the standpipe for buildings more than six stories in height?Generally, what is the standard diameter of the standpipe for buildings more than six stories in height?

    6 in.

  • 25

    Why is a wet standpipe with Siamese connection considered most practical?

    It is being served by the domestic water supply under constant pressure.

  • 26

    What is the disadvantage of the wet standpipe with Siamese connection?

    The danger of contamination of the building water supply from the unknown source.

  • 27

    What is the most practical method of repairing or correcting leak of a plastic pipe?

    Cut and insert coupling

  • 28

    Careful installation of the water supply distribution is essential. Which statement differs among the group?

    Short offset and unnecessary fittings

  • 29

    Damage to property leaking points, trapped piping and water hammer in a water system are attributed to ___.

    Poor workmanship

  • 30

    In what ways must the water distribution system be suspended from the basement ceiling in large concrete buildings?

    Iron inserted on the tough floor sheating and slushed into the concrete slab

  • 31

    What is that it is not good practice to use a gate valve on a lawn sprinkler?

    It will fail to close tightly.

  • 32

    Why must basement water supply must be properly graded and aligned?

    It is convenient to provide a drum valve to make it possible to drain the entire water system.

  • 33

    Where should gate valve be used?

    In between the main supply line and pump line.

  • 34

    What is the recommended distance above the flood level rim of a unit for a vacuum breaker to be installed?

    6 in.

  • 35

    In what instances that a mechanical drainage will be used?

    Drainage cannot be affected by gravity.

  • 36

    What kind of pipe usually used as leaders in tall buildings?

    Wrought iron pipe.

  • 37

    What will be the best kind of pipe for underground drains within the buildings?

    Cast iropn pipe

  • 38

    The drainage system in the building should be designed, constructed and maintained as to guard against fouling, deposits of solids and clogging. What feature should be provided to make maintenance efficient and effective?

    Adequate cleanouts

  • 39

    Why is rainwater leaders are often not included as part of the sanitary drainage system?

    Excessive rainwater hinders the treatment of the sewage.

  • 40

    Which word does not apply to the plumbing system?

    Smoke tight

  • 41

    If a plumbing plan scaled as 1:10,000, then 10 cm * 20 cm catchment area in the plan is equal to ___m^3 of rainfall in actual for every hour? Assume 100mm/hr rain intensity

    200,000m^3

  • 42

    What is the shape for the signage for the signage for women's comfort room; order to aid visually impaited women readily determine whether a washroom is for men or women?

    Circle

  • 43

    A fire sprinkler head has a k-factor of 7.6. What is the flow rate at 15 psi?

    29.4

  • 44

    All valves controlling the supply of a fire sprinkler system should be:

    Indicating

  • 45

    Where practical, all pipes from fixtures shall be run in what direction with respect to the nearest wall or building line?

    Parallel

  • 46

    By regulation, the minimum design pressure in distribution system is?

    30 psi

  • 47

    Are there major difference between sewer and septic system in your home?

    None of the above

  • 48

    Minimum height if Shower head.

    1.78m

  • 49

    What is the number one reason why pumps cavitate?

    Low pressure

  • 50

    What is the lead content in a brass fitting.

    5%