問題一覧
1
The acid trap must be drained at regular intervals
2
negative current on the ammeter gauge, reducing voltage and a red warning light
3
lower density of the electrolyte
4
under-frequency and under -voltage
5
remains unchanged and current consumption decreased
6
contact spring tension is adjusted
7
level of charge of the battery
8
provides hydraulic function for the CSD as well as cooling and lubrication
9
no damage will be done because the external power relay will de-energize automatically before the main pins are disconnected
10
A current transformer
11
capacitive and inductive components
12
quadrupled
13
star configuration
14
increase the pulse width
15
provide protection from induced current when the contactor is opened
16
excitation
17
high oil temperature or low oil pressure
18
the opposite magnetic polarity as the proceeding main poles (in direction of rotating of armature
19
main generator stator
20
the electrolyte level is higher level than normal
21
prevent the coil being fitted the wrong way
22
exciter armature and main generator field
23
only in the work shop
24
excessive charging current
25
activation of the time delay circuit.
26
high oil temperature / low oil pressure
27
voltage regulators
28
by power fed from a battery supplied static inverte
29
GCU
30
Sodium bicarbonate
31
DC to AC
32
incorporates the alternator and the CSD as one unit
33
120 out of phase with each other
34
1.4 volts
35
less maintenance
36
can be change independently
37
1.24-1.3
38
the armature
39
phase voltage
40
PMG
41
generator must be stationary
42
detects current difference between source and load
43
uses a voltage coil in parallel with generator output
44
Bus Power Control Unit BPCU
45
Zener and transistors
46
in series with the field and changes resistance with surface area contact
47
to enable generators to be paralleled
48
saw tooth AC ripple component
mod5 training
mod5 training
ユーザ名非公開 · 14問 · 1年前mod5 training
mod5 training
14問 • 1年前M6c1
M6c1
ユーザ名非公開 · 22問 · 1年前M6c1
M6c1
22問 • 1年前M6c2
M6c2
ユーザ名非公開 · 20問 · 1年前M6c2
M6c2
20問 • 1年前M6c3
M6c3
ユーザ名非公開 · 52問 · 1年前M6c3
M6c3
52問 • 1年前M6c4
M6c4
ユーザ名非公開 · 26問 · 1年前M6c4
M6c4
26問 • 1年前M6c5
M6c5
ユーザ名非公開 · 48問 · 1年前M6c5
M6c5
48問 • 1年前M6c6
M6c6
ユーザ名非公開 · 27問 · 1年前M6c6
M6c6
27問 • 1年前M6c7
M6c7
ユーザ名非公開 · 15問 · 1年前M6c7
M6c7
15問 • 1年前M6c8
M6c8
ユーザ名非公開 · 15問 · 1年前M6c8
M6c8
15問 • 1年前M6c9
M6c9
ユーザ名非公開 · 17問 · 1年前M6c9
M6c9
17問 • 1年前M6c10
M6c10
ユーザ名非公開 · 18問 · 1年前M6c10
M6c10
18問 • 1年前M6c11
M6c11
ユーザ名非公開 · 44問 · 1年前M6c11
M6c11
44問 • 1年前M7c1
M7c1
ユーザ名非公開 · 18問 · 1年前M7c1
M7c1
18問 • 1年前M7c2
M7c2
ユーザ名非公開 · 11問 · 1年前M7c2
M7c2
11問 • 1年前M7c3
M7c3
ユーザ名非公開 · 39問 · 1年前M7c3
M7c3
39問 • 1年前M7c4
M7c4
ユーザ名非公開 · 21問 · 1年前M7c4
M7c4
21問 • 1年前M10c1
M10c1
ユーザ名非公開 · 15問 · 1年前M10c1
M10c1
15問 • 1年前M7c5
M7c5
ユーザ名非公開 · 11問 · 1年前M7c5
M7c5
11問 • 1年前問題一覧
1
The acid trap must be drained at regular intervals
2
negative current on the ammeter gauge, reducing voltage and a red warning light
3
lower density of the electrolyte
4
under-frequency and under -voltage
5
remains unchanged and current consumption decreased
6
contact spring tension is adjusted
7
level of charge of the battery
8
provides hydraulic function for the CSD as well as cooling and lubrication
9
no damage will be done because the external power relay will de-energize automatically before the main pins are disconnected
10
A current transformer
11
capacitive and inductive components
12
quadrupled
13
star configuration
14
increase the pulse width
15
provide protection from induced current when the contactor is opened
16
excitation
17
high oil temperature or low oil pressure
18
the opposite magnetic polarity as the proceeding main poles (in direction of rotating of armature
19
main generator stator
20
the electrolyte level is higher level than normal
21
prevent the coil being fitted the wrong way
22
exciter armature and main generator field
23
only in the work shop
24
excessive charging current
25
activation of the time delay circuit.
26
high oil temperature / low oil pressure
27
voltage regulators
28
by power fed from a battery supplied static inverte
29
GCU
30
Sodium bicarbonate
31
DC to AC
32
incorporates the alternator and the CSD as one unit
33
120 out of phase with each other
34
1.4 volts
35
less maintenance
36
can be change independently
37
1.24-1.3
38
the armature
39
phase voltage
40
PMG
41
generator must be stationary
42
detects current difference between source and load
43
uses a voltage coil in parallel with generator output
44
Bus Power Control Unit BPCU
45
Zener and transistors
46
in series with the field and changes resistance with surface area contact
47
to enable generators to be paralleled
48
saw tooth AC ripple component