Question
initial ionizing event occurs on DNA–target molecule
Question
- initial ionizing event occurs in distant–non critical molecule - energy transferred to target molecule
Question
2 Types of Irradiation of MacroMolecules
Question
- Irradiation of macromolecules outside the body or outside the cell - Considerable radiation dose is required to produce a measurable effect
Question
- Irradiation of macromolecules within the living cell - More sensitive in their natural state
Question
3 Types of Irradiation Of Macromolecules in Vitro MCP
Question
the breakage of the backbone of the long-chain macromolecule.
Question
determines the degree of mainchain scission
Question
Process of side spurs created by irradiation & attached to a neighboring macromolecules or to another segment of the same molecule
Question
Cross linking increases the _______ of the macromolecular solution
RAD BIO 4
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
initial ionizing event occurs on DNA–target moleculeDirect Effects
2
- initial ionizing event occurs in distant–non critical molecule - energy transferred to target moleculeIndirect Effects
3
2 Types of Irradiation of MacroMolecules- In Vitro - In Vivo
4
- Irradiation of macromolecules outside the body or outside the cell - Considerable radiation dose is required to produce a measurable effectIn Vitro
5
- Irradiation of macromolecules within the living cell - More sensitive in their natural stateIn Vivo
6
3 Types of Irradiation Of Macromolecules in Vitro MCP- Main chain scission - Cross-linking - Point lesion
7
the breakage of the backbone of the long-chain macromolecule.Main chain scission
8
determines the degree of mainchain scissionMeasurement of Viscosity
9
Process of side spurs created by irradiation & attached to a neighboring macromolecules or to another segment of the same moleculeCross-linking
10
Cross linking increases the _______ of the macromolecular solutionViscosity
11
- Any change that results in the impairment or loss of function at the point of a single chemical bond - Not detectablePoint Lesion
12
At low radiation doses, _____ _____ are considered to be the cellular radiation damage that results in the stochastic radiation effects observed at the whole-body levelPoint Lesion
13
- Poisonous to the cell & therefore acts as a toxic agent - Formed by combination of two OH - Formed by combination of two Hydroperoxyl radicalsHydrogen Peroxide
14
- The principal damaging product of radiolysis of water - Formed by combination of H* and oxygenHydroperoxyl Radical
15
most important molecule in the human bodyDNA
16
3 Effects of Radiation on DNA CMG- Cell Death - Malignant Disease - Genetic Effect
17
- Designed to detect or measure radiation - it is used to indicate the presence of radiation - Operate in the ____ or ____ mode- Radiation Detection Instrument - pulse, rate
18
_________: the practice of measuring the intensity of radiation _________: the radiation-measuring devices- Dosimetry - Dosimeters
19
5 Types of Radiation Detection & Measuring Device PGTOS- Photographic Emulsion - Gas Filled Detectors - Thermoluminescence Dosimetry - Optically-Stimulated Luminescence Dosimetry - Scintillation Detection
20
- The earliest radiation detection device - limited range, sensitive & energy dependent - used for personnel monitoring & emulsion imagingPhotographic Emulsion
21
device used to measure radiation intensity & to detect radioactive contaminationGas-filled Detectors
22
Three Types of Gas-filled Detectors IPG- Ionization chamber - Proportional counter - Geiger Muller counter
23
In general, the _____ the chamber, the more gas molecules are available for ionization and therefore the more _______ the instrument.- larger - sensitive
24
- instrument of choice for measuring radiation intensity - wide range, accurate & portable survey for radiation levels 1 mR/hr or 10 uGy/hrIonization Chamber
25
- It is used for contamination control in nuclear medicine laboratories - limited to 100 mR/hr & portable survey for low radiation levels & radioactive contaminationGeiger-Muller Counter
26
- It has the ability to distinguish between alpha & beta radiation - Characteristics: laboratory equipment, accurate & sensitive - Uses: assay of small quantities of radionuclidesProportional Counter
27
- Basis for the gamma camera - It is used in the detectors arrays of CT imaging system - It is used as IR in digital imaging systemScintillation Detection
28
- limited range, very sensitive, & stationary or portable instruments - Materials: NaI:Tl or CsI:TlScintillation Detection
29
- Discovered in the 1960 at the University of Wisconsin. - When exposed to ionizing radiation the crystals in this undergo structural changes that remains essentially stable until the crystal is heated. When heated, the stored energy is released as light.Thermoluminescence Dosimetry
30
4 Materials of Thermoluminescence Dosimetry (LF, CF, LB, CS)- Lithium Fluoride - Calcium Fluoride - Lithium Borate - Calcium Sulfate
31
- Advantages: Size, Reusable, Responds proportionately to dose, Rugged - Characteristics: wide range, accurate & sensitive as low as 5 mrad >10 rad - Uses: personnel monitoring, stationary & area monitoringThermoluminescence Dosimetry
32
- Developed by Laundauer in late 1990s - Material: Aluminum oxide Step Process: • Exposure to ionizing radiation • Laser illumination • Measurement of the intensity of stimulated light emissionOptically Stimulated Luminescence Dosimetry
33
Reanalysis Wide dynamic range Excellent long-term stabilityAdvantage of OSL over TLD