Question
What is the cm of the universally accepted SID?
Question
What will happen if the source-to-image-receptor-distance (SID) is increased? It will increase what?
Question
There is an inverse relationship between the SID and the radiation exposure at the image receptor If the SID increases, the IR exposure what?
Question
The greater the __, the less magnification the image will suffer.
Question
Exposure index is indirectly proportional to the speed class of operation. True or False
Question
CR typically operate at a lower speed class than DR systems. True or False
Question
as speed class increases, so does the amount of?
Question
allows the radiographer to match the exposure to the desired speed class of operation.
Question
defined as the log to the base 10 of the incident light intensity divided by the transmitted intensity.
Question
Number of Speed class used in Film-screen systems for general radiography
C5 Orig V2
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
What is the cm of the universally accepted SID?100 cm
2
What will happen if the source-to-image-receptor-distance (SID) is increased? It will increase what?Image Sharpness
3
There is an inverse relationship between the SID and the radiation exposure at the image receptor If the SID increases, the IR exposure what?Decreases
4
The greater the __, the less magnification the image will suffer.SID
5
Exposure index is indirectly proportional to the speed class of operation. True or FalseTrue
6
CR typically operate at a lower speed class than DR systems. True or FalseTrue
7
as speed class increases, so does the amount of?Image Noise
8
allows the radiographer to match the exposure to the desired speed class of operation.Exposure Index
9
defined as the log to the base 10 of the incident light intensity divided by the transmitted intensity.Optical Density
10
Number of Speed class used in Film-screen systems for general radiography400-speed class
11
Bucky factor changes with the change of what? K, GR- change in kVp - change in grid ratio
12
ratio of x-rays arriving at the grid (incident radiation), and those being transmitted through the gridBucky Factor
13
defines the requirement to increase the exposure factors to maintain density with the use of a grid.Grid Factor
14
- ratio of radiation on the anti-scatter grid to the transmitted radiation - reflects the increased radiation dose required from anti-scatter grid use, as any increase in mAs proportionally increases dose.Bucky Factor
15
states that as long as mAs is the same, any combination of mA and time can be used to produce the same quantity of radiation and therefore the same densityReciprocity Law
16
As one factor changes, however, the other must also change equally in the what? to maintain proper exposureOpposite Direction
17
Ignoring the reciprocity law causes?Underdeveloped/Overexposed photos.
18
the reaction of a photographic emulsion to light will be equal to the products of the intensity of that light and the time of the exposure.Reciprocity Law
19
To calculate milliampere seconds (mAs), multiply the Milli-amp bytime in seconds.
20
reduces radiographic contrastScattered radiation or high kVp: because high kVp increases scatter radiation
21
low kVp beam will produce a radiograph with what level of contrast?high
22
A high kVp beam will produce a radiograph with what level of contrast?Low contrast
23
exposure factor that controls radiographic contrast.kVp
24
refers to the concentration, in air, of x-rays at a specific point and is the ionization produced in a specific volume of airExposure
25
- product of the mA and time and is calculated by multiplying the mA by the time. - represents the total quantity of x-rays produced in a beam.mAs
26
What is the formula in computing the kVp?measured thickness in centimetres x 2 + 40 = initial kVp
27
6 Influencing factors for Receptor Exposure AGFCAP- Automatic Exposure Control - Grid - Filtration - Collimation - Anode Heel Effect - Patient Factors
28
4 Receptor Exposure Prime Factors MEKS- mA - Exposure Time - kVp - SID
29
Exposure Indicator Names SRIEE- S-number, - REG, - IgM, - Exl - Exposure Index.S
30
is a vendor-specific value that provides the radiographer with an indication of the accuracy of their exposure settings for a specific image (ASRT, 2010).Indicator
31
- measure of radiation in the relevant image region on the receptor. - function of the region of interest (ROI) selected by the digital radiography workstation for the examination type, image processingn, exposure usedExposure Index
32
2 types of digital image receptors DSS IPSPP- Direct Solid State - Indirect Photostimulable Phosphor Plates
33
are the receptors for the digital image, instead of using traditional x-ray film.Sensors
34
Does CR and DR use chemicals? Yes or No?No
35
A digital image is stored and can be post processed by changing what? MOBC- Magnification - Orientation - Brightness - Contrast
36
uses a special electronic x-ray detector, which converts the radiographic image into a digital picture for review on a computer monitorDigital Radiography
37
PACS meaningPictures Archiving and Communications System
38
The ___ layer of the flat panel detector houses the thin-film transistor (TFT)2nd
39
The ____ layer of the flat panel detector is composed of the x ray converter1st
40
3 things integrated into the flat panel device SS, SRO, DE- Signal storage - Signal read out - Digitizing electronics