POI P2

41 questions • 2024-09-30
E
Report

Question

contribute to overall radiographic quality

Answer

Question

2 Geometric Qualities ______ - distinct representation of objects true borders, edges ______ - misinterpretation of true size or shape of an object

Answer

Question

degree of difference or ratio between

Answer

Question

no differences in density

Answer

Question

object with different absorption characteristics produces an image with varying densities

Answer

Question

Evaluating radiographic quality in contrast is ______

Answer

Question

- controlling factor of contrast - difference in potential applied to x-ray tube - directly proportional to average x-ray spectrum or x-ray quality - plays role in adjusting amount of penetration in an acquisition - energy of x-rays (higher penetrability)

Answer

Question

examples of: low subject contrast > high kVp > long scale contrast

Answer

Question

examples of: high subject contrast > low kVp > short scale contrast >

Answer

Question

properties that comprise visibility of detail. Appear Gray

Answer

POI P2

TestMaker

Score

0 / 10

Correct rate

0%

Correct: 0

Incorrect: 0

Unanswered: 10

 
ankimaker.com

Question list

  • 1

    contribute to overall radiographic quality

    Geometric Qualities

  • 2

    2 Geometric Qualities ______ - distinct representation of objects true borders, edges ______ - misinterpretation of true size or shape of an object

    - Recorded detail - Distortion

  • 3

    degree of difference or ratio between

    Radiographic Contrast

  • 4

    no differences in density

    Homogenous Object

  • 5

    object with different absorption characteristics produces an image with varying densities

    Differential Absorption

  • 6

    Evaluating radiographic quality in contrast is ______

    Subjective

  • 7

    - controlling factor of contrast - difference in potential applied to x-ray tube - directly proportional to average x-ray spectrum or x-ray quality - plays role in adjusting amount of penetration in an acquisition - energy of x-rays (higher penetrability)

    kVp

  • 8

    examples of: low subject contrast > high kVp > long scale contrast

    Air/Fluid

  • 9

    examples of: high subject contrast > low kVp > short scale contrast >

    Bone

  • 10

    properties that comprise visibility of detail. Appear Gray

    Contrast

  • 11

    visible to human eye

    Visibility of detail

  • 12

    difference between adjacent densities

    Image Contrast

  • 13

    number of useful visible densities or shades of gray

    Scale of Contrast

  • 14

    described by scale of contrast

    Radiographic Images

  • 15

    conversion factor between exposure to ionizing radiation

    Technique Conversion Factors

  • 16

    what to do To maintain exposure when increasing kVp:

    - increase kVp by 15% - reduce mAs to half

  • 17

    what to do To maintain exposure when decreasing kVp:

    - decrease kVp 15% - multiply mAs by 2

  • 18

    tissues that makeup the human body that attenuate the beam of radiation

    Patient Factors

  • 19

    - device used to improve contrast of radiographic image - absorbs scattered radiation before it reaches image receptor - employed when body part thickness is greater than 10cm or kVp is 60 - used for obese patients

    Grid

  • 20

    3 X-ray Interaction through the body PBI

    - Pass through the body - Be absorbed by body - Interact & change direction

  • 21

    interaction that produces scatter radiation

    Compton Interaction

  • 22

    3 Amount of Scatter Radiation increase with: ILD

    - Increased patient thickness - Larger field sizes - Decrease in atomic number of tissue

  • 23

    account for lead content of grid

    Grid Conversion Factor aka Bucky Grid

  • 24

    - placed in cassette close contact with film, function is to reinforce the action of x-rays - amplify the incoming x-ray beam - introduced by Thomas Edison in 1896

    Intensifying Screens

  • 25

    2 TYPES OF INTENSIFYING SCREENS

    - Calcium Tungstate: blue light - Rare Earth: green light

  • 26

    percent of x-rays that reach cassette

    33%

  • 27

    invisible product of x-ray film

    Latent Image

  • 28

    4 PARTS OF INTENSIFYING SCREEN BRPP

    - Base Layer - Reflective Layer - Phosphor Layer - Protective Coat

  • 29

    layer of IS that is polyester or cardboard or metal

    Base Layer

  • 30

    layer of IS that is made up of magnesium oxide or titanium dioxide

    Reflective Layer

  • 31

    active layer of IS , absorbs energy

    Phosphor Layer

  • 32

    protects phosphor layer from abrasions

    Protective Coat

  • 33

    3 Types of Beam Restrictors ACC

    - Aperture Diaphragms - Cones/Cylinder - Collimators

  • 34

    beam restrictor that is a flat sheet of metal

    Aperture diaphragms

  • 35

    circular aperture diaphragms

    Cones/Cylinder

  • 36

    commonly employed beam restriction

    Collimators

  • 37

    purpose is to deposit enough metallic silver at latent image sites

    Film Processing

  • 38

    4 Processing Steps

    > Developing - silver is deposited at latent image > Fixing - clearing agent > Washing - water to remove developer solutions > Drying - hot air

  • 39

    critical part of archiving process

    Storage

  • 40

    radiograph time or expiry

    5-7 years

  • 41

    - visibility of anatomy and sign of pathology - affected by photographic and geometric quality

    Image Quality