Question
invented x-ray grid in 1913
Question
working ability of a grid is described, ratio of height
Question
Grid Ratio used for Greater than 90 kVp - for 20-40 kVp (mammography)- for 70-90 kVp -
Question
ratio of incident radiation
Question
no actual grid, latest innovation for scatter radiation
Question
strips are slightly angled, used at specified focal distance
Question
used for short or long distance
Question
eliminates fine grid lines
Question
Layers of Intensifying Screen BRLP
Question
What phosphor layer emits blue light? CT & LO
M4
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
invented x-ray grid in 1913Dr. Gustav Bucky
2
working ability of a grid is described, ratio of heightGrid Ratio
3
Grid Ratio used for Greater than 90 kVp - for 20-40 kVp (mammography)- for 70-90 kVp -- 12:1 - 5:1 - 8:1
4
ratio of incident radiationBucky Factor
5
no actual grid, latest innovation for scatter radiationVirtual Grid
6
strips are slightly angled, used at specified focal distanceFocused Grid
7
used for short or long distanceParallel Grid
8
eliminates fine grid linesMoving Grid
9
Layers of Intensifying Screen BRLP- Base - Reflective Layer - Luminescent Layer/Phosphor Layer - Protective Layer
10
What phosphor layer emits blue light? CT & LO- Calcium Tungstate - Lanthanum Oxybromide
11
What phosphor layer emits green light? G.0Gadolinium Oxysulfide
12
Rare Earth Elements GLYGadolinium Lanthanum Yttrium
13
* film sensitive to UV, Blue, Green Light * film sensitive to UV & Blue Light- Orthrochromatic Films - Conventional Films
14
2 Processing Errors that affect density- Underdevelopment - Overdevelopment
15
processing that requires rigorous quality controlAutomatic Processing
16
controls density of radiographmAs
17
What Scatter is Decreased, Contrast is what?Increased
18
magnifying the anatomical structure, usually caused by increased OIDSize Distortion
19
can be controlled by proper exposure factorMagnification
20
misinterpretation of shape, controlled by alignment of beam, referred as true distortionShape Distortion
21
Influencing factors of shape distortion include: CB- Central ray angulation - Body part rotation
22
central portion of the beamCentral Ray
23
number used to change one set of unitsTechnique Conversion Factors
24
alters intensity of beamSID
25
- compromise visibility of detail - degree of overall blackeningDensity
26
describe concept of density displayed on soft copy monitor, amount of luminescenceBrightness
27
describe the digital processing that produce changeWindow Level
28
5 Factors affecting density KFABA- kVp, mAs - focal spot - anode heel effect - beam restriction - anatomical part
29
effect that alters intensityAnode Heel Effect
30
great deal of influence on IR and film densityAnatomical Part
31
affects recorded detail, fails enough time for image to formMotion
32
* patient based artifact that occur with voluntary and involuntary movement * under the direct control of patient * not under the control of patient- Motion Artifact - Voluntary Motion - Involuntary Motion
33
technique used to track movement of objects with xrays ex. cartilageX-ray Motion Analysis
34
instrument that provides a read of amount of blackening or densityDensitometer
35
unwanted absorption of x-rays via an x-ray gridGrid Cut Off
36
to minimize distortionTarget Object Film Alignment
37
Use only the SID distances of?40” 56” 72”
38
What do with mAs when distance increases? when distance decreases?- double mAs - halve mAs
39
Restricting beam does what? RN, RA, RO- reduce number of photons - reduce amount of scatter radiation - reduce overall IR exposure & film density
40
Scatter rad is produced when? HL- high kVp - large anatomic size
41
can alter absorption characteristics of anatomic partPathologic Conditions
42
- conditions that increase absorption characteristics, making it difficult to penetrate - conditions that decrease the absorption characteristics, making part easier to penetrate- Additive Diseases - Destructive Diseases
43
BEST METHODS IN REDUCING MOTION IN ORDER1st - Communication 2nd - Reduce Exposure Time 3rd - Immobilization
44
major controller of image resolution and penumbraFocal Spot Size
45
- what focal spot reduces bluriness or penumbra effect and is used where spatial resolution is important (mammography) - what focal spot results in more unsharpness and reduced recorded detail, used when shorter exposure time is prio- Small Focal Spot - Large Focal Spot
46
The ________ between source or focal spot, object, part and image receptor are critical in establishing sufficient recorded detailDistance
47
when OID is decreased, resolution is ________ when SID is increased, resolution and recorded detail is ________- increased - increased
48
distance between focal spot and radiographic filmFocal Film Distance
49
- lower x-ray beam intensity - need higher mAs to prevent underexposure- Greater FFD - Longer FFD
50
commonly classified by speedFilm/Screen Combination
51
Slow Film Screen Combination equals to better or worse resolution?Better
52
helps control geometric distortion and grid cut offTube-object film alignment
53
degree to which radiation is attenuated, depends on cell component, relative atomic no, thickness, cell densityPatient Factors
54
- anything that changes the nature of radiation beam - purpose is scatter controlBeam Modification
55
- filtration from components of x-ray tube - filtration from interchangeable metal sheetsInherent Filtration Added Filtration
56
filtration used in mammographyBeryllium
57
Diagnostic X-ray Beams are _________ (meaning spectrum of many diff energies)Polychromatic
58
substance that attenuates the beam to a different degree than surrounding tissueContrast Media