Question
- produced ISOTROPICALLY and has EQUAL INTENSITY to all directions - SIZE is VARIABLE by using X-RAY BEAM COLLIMATORS - Intercepted by MATTER & TISSUE.
Question
- Produced by using a HIGH VOLTAGE and an ELECTRIC CURRENT - Produced when FAST MOVING ELECTRONS coming from the cathode interacts with the target in the anode
Question
this is the x-rays emitted through the window of the x-ray tube The actual x-ray beam that is intercepted by the patient
Question
Transmitted from the x-ray tube to the image receptor. The QUALITY and QUANTITY of this can be determined by the !kVp and mAs! It should never be directed at the radiologic technologist, other personnel, or the control booth.
Question
imaginary line in the useful beam centermost part of the x-ray beam should be aligned to the center of the structure being imaged and grid if being used.
Question
Particularly important in radiographic positioning and reducing image distortion
Question
If the intensity of the central ray is 100%, what is the x-ray intensity on the cathode and anode side?
Question
The part of the x-ray beam that exits the patient after interaction. Interact with the patient and are scattered away.
Question
any x-rays that escape the protective housing of the X-ray tube Contributes nothing in the way of diagnostic information and results in unnecessary exposure of the patient and radiologic technologist. Must not exceed !!100 mR/hr at !!1m!!
Question
also known as Extrafocal X-rays
RPC M2.5
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
- produced ISOTROPICALLY and has EQUAL INTENSITY to all directions - SIZE is VARIABLE by using X-RAY BEAM COLLIMATORS - Intercepted by MATTER & TISSUE.X-rays
2
- Produced by using a HIGH VOLTAGE and an ELECTRIC CURRENT - Produced when FAST MOVING ELECTRONS coming from the cathode interacts with the target in the anodeX-rays
3
this is the x-rays emitted through the window of the x-ray tube The actual x-ray beam that is intercepted by the patientPrimary Beam/Useful Beam
4
Transmitted from the x-ray tube to the image receptor. The QUALITY and QUANTITY of this can be determined by the !kVp and mAs! It should never be directed at the radiologic technologist, other personnel, or the control booth.Primary Beam
5
imaginary line in the useful beam centermost part of the x-ray beam should be aligned to the center of the structure being imaged and grid if being used.Central Ray
6
Particularly important in radiographic positioning and reducing image distortionCentral Ray
7
If the intensity of the central ray is 100%, what is the x-ray intensity on the cathode and anode side?Cathode - as high as 120% Anode - as low as 75%
8
The part of the x-ray beam that exits the patient after interaction. Interact with the patient and are scattered away.Exit/Remnant Beam
9
any x-rays that escape the protective housing of the X-ray tube Contributes nothing in the way of diagnostic information and results in unnecessary exposure of the patient and radiologic technologist. Must not exceed !!100 mR/hr at !!1m!!Leakage Radiation
10
also known as Extrafocal X-raysOff-Focus/Stem Radiation
11
During off focus radiation creation, this bounce off the focal spot and land on other areas of the target causing x-rays to be produced from outside of the focal spot.Electrons
12
designed so that the projectile electrons from the cathode interacts with the target only at the focal spot. considered to be an ineffective deviceX-rays tubes
13
x-rays formed outside of the focal spot area undesirable because it extends the focal spot size increasing the skin dose unnecessarily Can reduce the radiographic image contrast.Off-focus radiation
14
Can also be reduced by the use of metal enclosures which extract and conduct the reflected electrons Can be a reason that tissue that was meant to be excluded, appear on the radiograph Reduced by using a fixed diaphragm inside the x-ray tube near its window.Off-focus radiation
15
energy in motionKinetic Energy
16
Ions with high kinetic energy focused toward a small spot on the anode are necessary for x-ray production. TRUE OR FALSE?False. Electrons, not ions
17
Kinetic Energy EquationsKE = (1/2)(mv^2) M - mass in kg V - velocity in meters per second KE - kinetic energy in joules
18
expression of energy of x-raysKilo electron volts
19
How many joules in 1 keV1.6 x 10^-16 J
20
primary function is to accelerate electrons from cathode to anodeX-ray imaging system
21
distance of the filament to the target1 cm
22
most of the projectile electrons' kinetic energy is converted into thisHeat
23
99% of projectile electron interaction is converted into thisThermal Energy
24
interact with outer shell electrons which causes excitation then return to the original state.Projectile electrons
25
2 incidents that are responsible for most heat generated in the Anodeconstant excitation and return to normal state
26
How to increase the anode heat of Tube Current?Increase mAs
27
How to increase anode heat of Tube Voltage?Increase kVp
28
percentage of anode heat used in x-ray production1%
29
Electrons traveling from the cathode to anode These electrons interact with the orbital electrons or the nuclear field of the target atoms interact with an inner shell electron and ionizes it leaving a void to be filled by an outer shell electronProjectile electrons
30
When electrons hit the anode, they transfer their kinetic energy toTarget atoms
31
what are 2 results of electrons interacting with orbital electrons or nuclear field. Formation of what?formation of thermal energy and electromagnetic energy
32
produced when an outer shell electron fills an inner shell void Emission of x-ray occurs as the outer shell electron fills the inner shellCharacteristic Radiation
33
occurs when radiation is produced by any other outer shell electron filling a K shell vacancyK X-rays
34
only ones useful in x-ray imaging as all other outer shell electron binding energy is lower than of a K-shell electronK-characteristic x-rays of tungsten
35
require an x-ray tube with a potential of 69 kVp and up since the K-shell electron of a tungsten target has an effective energy of 69 KeVK-shell X-rays
36
german word meaning “slowed down”Bremsstrahlung
37
results from the braking of projectile electrons by the nucleus of an atom, where the projectile electrons completely avoids the orbital electrons as it passes through the target atom and may come close enough to the nucleus to interact with its electric fieldBremsstrahlung Radiation
38
where projectile electron loses its kinetic energy as it interacts with this then changes directionNuclear Force Field
39
what lost kinetic energy is converted intoElectromagnetic energy
40
causes the "braking" down of electrons occurs between nucleus of atom and projectile electronsElectrostatic force of attraction
41
Charge of a nucleus of an atompositively charged
42
charge of Projectile electronsnegatively charged
43
results when the projectile electrons barely interact with the nuclear force fieldLow energy bremsstrahlung x-rays
44
how much energy can be produced in bremsstrahlung radiation?1 keV to 70 keV
45
In diagnostic range, most x-rays are?Bremsstrahlung x-rays