POI P3

24 questions • 2024-09-30
E
Report

Question

exposure without screens over exposure with screens

Answer

Question

amount of light emitted by screen for given amount of exposure

Answer

Question

2 Types of Screen Speed

Answer

Question

should be used to reduce patient exposure

Answer

Question

- can increase beam penetration when high, - affects exposure to IR, - can cause larger potential difference when increased

Answer

Question

needed to achieve a desired exposure to the IR

Answer

Question

2 principal factors that affect amount of scattered radiation KI

Answer

Question

scattering of incident photons onto an outer shell electron of atom

Answer

Question

energy of incident photon is totally absorbed by inner shell electron which is ejected (Photoelectron) with kinetic energy

Answer

Question

photon energy is converted to positron and electron

Answer

POI P3

TestMaker

Score

0 / 10

Correct rate

0%

Correct: 0

Incorrect: 0

Unanswered: 10

 
ankimaker.com

Question list

  • 1

    exposure without screens over exposure with screens

    Intensifying Factors

  • 2

    amount of light emitted by screen for given amount of exposure

    Screen Speed

  • 3

    2 Types of Screen Speed

    2 Types of Screen Speed * FAST - creates an increased amount of light compared with slow * SLOW

  • 4

    should be used to reduce patient exposure

    high kVp & lower mAs

  • 5

    - can increase beam penetration when high, - affects exposure to IR, - can cause larger potential difference when increased

    kVp

  • 6

    needed to achieve a desired exposure to the IR

    Less Radiation

  • 7

    2 principal factors that affect amount of scattered radiation KI

    Kilovoltage, Irradiated Materials

  • 8

    scattering of incident photons onto an outer shell electron of atom

    Compton Scattering

  • 9

    energy of incident photon is totally absorbed by inner shell electron which is ejected (Photoelectron) with kinetic energy

    Photoelectric Absorption

  • 10

    photon energy is converted to positron and electron

    Pair Production

  • 11

    transfers negligible energy to atom

    Coherent Scattering

  • 12

    related to contributions of scattered photons at calibration

    Correction Factor in Radiology

  • 13

    ratio of true dose rate to instrument’s response rate

    Correction Factor in Radiation

  • 14

    - technical challenge for radiographers because of small size, require lower kVp & mAs - requires technologist to choose fast exposure

    Pediatric patients

  • 15

    eliminate possibility of using automatic exposure control (AEC)

    Fast exposure time

  • 16

    higher risk for children than adults

    Thyroid & Skin Cancer

  • 17

    Exposure factors for adult skulls can be used for pedia patients _ years older

    6

  • 18

    decrease kVp by 15% to compensate

    When lacking bone density

  • 19

    2 FACTORS THAT CAN CAUSE MAGNIFICATION DP

    - distance from plate - printing or monitoring radiographs

  • 20

    Steel balls ___mm, difference in size between center less than ___mm

    25.4mm 0.3mm

  • 21

    can be produced with materials that attenuate x-rays

    Casts/Splints

  • 22

    made of fiberglass or plaster

    Casts

  • 23

    MATERIALS THAT REQUIRE NO INCREASE IN EXPOSURE FA

    Fiberglass Air

  • 24

    MATERIALS THAT REQUIRE AN INCREASE IN EXPOSURE WASP

    Wood Aluminum Solid Plastic Splints Plaster