Question
IR of Conventional X-ray?
Question
IR of Computed Radiography
Question
IR of Digital Radiography
Question
represents the amount of current passed through the X-ray tube.
Question
determines the number of photons the X-ray tube produces, also known as X-ray quantity.
Question
Total exposure time is measured in what unit?
Question
controls the length of the x-ray exposure by determining how long the current (mA) will be passing through the x-ray tube.
Question
measure of radiation produced (milliamperage) over a set amount of time (seconds) via an x-ray tube.
Question
calculation for receptor exposure formula
Question
pertains to mAs in the sense that all combinations of mA x seconds that amount to an equal quantity will produce the same amount of density.
C5 Part 2
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
IR of Conventional X-ray?Film Screen Cassette
2
IR of Computed RadiographyImaging Plate
3
IR of Digital RadiographyFlat Panel Detector
4
represents the amount of current passed through the X-ray tube.mA
5
determines the number of photons the X-ray tube produces, also known as X-ray quantity.Current
6
Total exposure time is measured in what unit?Seconds
7
controls the length of the x-ray exposure by determining how long the current (mA) will be passing through the x-ray tube.Exposure time
8
measure of radiation produced (milliamperage) over a set amount of time (seconds) via an x-ray tube.Milliampere-seconds (mAs)
9
calculation for receptor exposure formulamas1 over mas2 equals D1^2 over D2^2
10
pertains to mAs in the sense that all combinations of mA x seconds that amount to an equal quantity will produce the same amount of density.Reciprocity Law
11
________ with a longer time allow for less patient motionsmaller mA
12
measures how much scatter is removed by the grid and how the mechanical factors be adjusted to produce the same optical density.Bucky Factor
13
ratio of the mAs required with the grid to the mAs required without the grid to produce the same optical densityBucky Factor
14
Use of grid increases what by the Bucky?Patient dose
15
of a film represents the amount of radiation required to produce a radiograph of acceptable density.Speed Class
16
As the speed of the film increase, the amount of radiation needed to properly expose it will what?Decrease
17
Increasing speed also decreases image noise. True or FalseFalse. Increase
18
Speed for routine work: Speed for high detail:• 200-800 • 50-100
19
speed films that are small grain, better definition, more exposureSlow speed films
20
Letter of each Fast Speed Films (ultra ekta speed) (ekta speed) (ultra speed)F E D
21
can be measured by - intensification factor, - relative name or speed valueScreen Speed
22
exposure required to create a certain optical density without a screen is divided by the exposure required with a screen to create the same optical density determines?Intensification Factor
23
distance between the x-ray tube and the image receptor is theSource to Image Distance (SID)
24
Screen speed used for high resolution?Slow
25
Screen speed used for regular/standardMedium
26
Screen speed used for fast screen?Fast
27
According to inverse square law, if you move twice as far from the source the intensity of the radiation will decrease by a factor of what?4