ログイン

WT 1
50問 • 13日前
  • ユーザ名非公開
  • 通報

    問題一覧

  • 1

    A Master Plumber shall live up to the standards of the professional practice of plumbing.

    Article III, Section 3 of Code of Ethics

  • 2

    A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.

    Wye

  • 3

    This examination subject in Master Plumbing was originally split into two.

    Practical Problems

  • 4

    What is the standard length of Galvanized Iron Pipe?

    6 m

  • 5

    The birth of the plumbing profession in the Philippines is traced back to the ___ century.

    17th

  • 6

    What is NOT included in a plumbing unit?

    Urinal

  • 7

    The Plumbing Code has been in existence for almost _____ since its promulgation before it has been amended.

    40 years

  • 8

    Which is not a proper connection for HDPE pipes?

    solvent cement

  • 9

    Depth of the molten pig lead in a caulked joint

    25.4 mm

  • 10

    Minimum weight of a lead for flashing or vent terminals

    14.63 kg per sqm

  • 11

    Preferred when a piece of pipe needed is shorter than 150 cm long

    Double Hub

  • 12

    A water heater is classified as?

    Plumbing Appliance

  • 13

    Color for Type M copper pipe

    Red

  • 14

    Distance of bottom of all pipe tranches to the footing of any adjacent building or structure parallel to it

    45 degrees

  • 15

    Each fixture directly connected to the drainage system shall be equipped with a _____.

    water-sealed trap

  • 16

    Tube made of plastic material and colored black. The crosssectional shape is normally oval and is denoted by its outside diameter or 0.D.

    Polybutylene

  • 17

    A set of moral principles or values to govern the conduct of an individual belonging to a group or profession on the basis of honestly, fairness, and justice.

    Ethics

  • 18

    1 fixture unit is equal to?

    7.48 gallons per minute

  • 19

    An open return bend usually made up of two 90° bends

    Return bend

  • 20

    Every building where _____ shall have a sewer service connection to a public or private sewer systems.

    plumbing fixtures are installed

  • 21

    Roughing-in of cold and hot water supply line are ideally distanced at least _____ apart.

    8"

  • 22

    What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?

    Decrease in DFU loading

  • 23

    A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____.

    120 days

  • 24

    Each member of the board, shall at the time of his appointment be at least _____ of age.

    30

  • 25

    An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread.

    Slip Joint

  • 26

    The Administrative Authority must be notified at least ___ working days before such inspection is intended.

    3

  • 27

    Any pipe or fitting installed at an angle of more than 45 degrees with the vertical line.

    horizontal pipe

  • 28

    Which authority is responsible for the administration and enforcement of the National Plumbing Code?

    Plumbing Official

  • 29

    The top edge of a receptacle from where water overflows.

    Flood Level Rim

  • 30

    Elastomeric gasketed and rubber-ring joints shall comply with _____ installation standard

    IAPMO

  • 31

    ASTM means?

    American Society for Testing and Materials

  • 32

    For caulked-on closet ring, the minimum overall depth shall be:

    2"

  • 33

    Wiped lead joints shall have an exposed surface on each side of a joint not less than _____.

    19 mm

  • 34

    The year when NAMPAP was organized and registered with the Securities and Exchange Commission

    1935

  • 35

    All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application.

    6

  • 36

    What is the accreditation number of NAMPAP?

    14

  • 37

    Code on Sanitation of the Philippines

    PD 856

  • 38

    Common maximum service temperature rating of PVC

    140 deg. F

  • 39

    The following are grounds for non-issuance of the certificate of registration by the Board of Master Plumbers except for _____.

    failure to pay the required fees

  • 40

    Vertical support of _____ is placed not less than every other storey height.

    Screwed Pipe

  • 41

    Plumbing fixtures shall be made of smooth non-absorbent material, free from concealed fouling surfaces and shall be located in ventilated enclosures

    Principle No. 7

  • 42

    Trap arm size of Laundry Tub

    38 mm

  • 43

    IPS shall be supported at ___ intervals for piping 19 mm diameter and smaller.

    3 m

  • 44

    A pipe flange that is not drilled for bolt holes.

    blank flange

  • 45

    Integrated within an air accumulator vessel which is designed to discharge a predetermined quantity of water into fixtures for flushing purposes

    Flushometer Tank

  • 46

    The Old Fire Code of the Philippines

    PD 1185

  • 47

    A pipe or conduit for carrying sewage and wastewater .

    Sewer

  • 48

    Who is the current chairman of the Board of Examiners for Master Plumber?

    Reynald B. Ilagan

  • 49

    (ANSI) Pipe Color code for Fire Quenching

    Red with White Lettering

  • 50

    Any change, addition or modification in construction or occupancy

    Alteration

  • YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 13日前

    YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    100問 • 13日前
    ユーザ名非公開

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 13日前

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    100問 • 13日前
    ユーザ名非公開

    Project Engineer YT 1

    Project Engineer YT 1

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer YT 1

    Project Engineer YT 1

    100問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM

    Project Engineer EXAM

    ユーザ名非公開 · 62問 · 13日前

    Project Engineer EXAM

    Project Engineer EXAM

    62問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    100問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    100問 • 13日前
    ユーザ名非公開

    July 2023 PE Refresher

    July 2023 PE Refresher

    ユーザ名非公開 · 70問 · 13日前

    July 2023 PE Refresher

    July 2023 PE Refresher

    70問 • 13日前
    ユーザ名非公開

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    ユーザ名非公開 · 93問 · 13日前

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    93問 • 13日前
    ユーザ名非公開

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    ユーザ名非公開 · 86問 · 13日前

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    86問 • 13日前
    ユーザ名非公開

    Plumbing Code 4

    Plumbing Code 4

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 4

    Plumbing Code 4

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 5

    Plumbing Code 5

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 5

    Plumbing Code 5

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 6

    Plumbing Code 6

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 6

    Plumbing Code 6

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 7

    Plumbing Code 7

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 7

    Plumbing Code 7

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 8

    Plumbing Code 8

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 8

    Plumbing Code 8

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 3

    Plumbing Code 3

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 3

    Plumbing Code 3

    100問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    ユーザ名非公開 · 97問 · 13日前

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    97問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    ユーザ名非公開 · 99問 · 13日前

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    99問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    ユーザ名非公開 · 96問 · 13日前

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    96問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    ユーザ名非公開 · 95問 · 13日前

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    95問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    ユーザ名非公開 · 97問 · 13日前

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    97問 • 13日前
    ユーザ名非公開

    問題一覧

  • 1

    A Master Plumber shall live up to the standards of the professional practice of plumbing.

    Article III, Section 3 of Code of Ethics

  • 2

    A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.

    Wye

  • 3

    This examination subject in Master Plumbing was originally split into two.

    Practical Problems

  • 4

    What is the standard length of Galvanized Iron Pipe?

    6 m

  • 5

    The birth of the plumbing profession in the Philippines is traced back to the ___ century.

    17th

  • 6

    What is NOT included in a plumbing unit?

    Urinal

  • 7

    The Plumbing Code has been in existence for almost _____ since its promulgation before it has been amended.

    40 years

  • 8

    Which is not a proper connection for HDPE pipes?

    solvent cement

  • 9

    Depth of the molten pig lead in a caulked joint

    25.4 mm

  • 10

    Minimum weight of a lead for flashing or vent terminals

    14.63 kg per sqm

  • 11

    Preferred when a piece of pipe needed is shorter than 150 cm long

    Double Hub

  • 12

    A water heater is classified as?

    Plumbing Appliance

  • 13

    Color for Type M copper pipe

    Red

  • 14

    Distance of bottom of all pipe tranches to the footing of any adjacent building or structure parallel to it

    45 degrees

  • 15

    Each fixture directly connected to the drainage system shall be equipped with a _____.

    water-sealed trap

  • 16

    Tube made of plastic material and colored black. The crosssectional shape is normally oval and is denoted by its outside diameter or 0.D.

    Polybutylene

  • 17

    A set of moral principles or values to govern the conduct of an individual belonging to a group or profession on the basis of honestly, fairness, and justice.

    Ethics

  • 18

    1 fixture unit is equal to?

    7.48 gallons per minute

  • 19

    An open return bend usually made up of two 90° bends

    Return bend

  • 20

    Every building where _____ shall have a sewer service connection to a public or private sewer systems.

    plumbing fixtures are installed

  • 21

    Roughing-in of cold and hot water supply line are ideally distanced at least _____ apart.

    8"

  • 22

    What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?

    Decrease in DFU loading

  • 23

    A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____.

    120 days

  • 24

    Each member of the board, shall at the time of his appointment be at least _____ of age.

    30

  • 25

    An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread.

    Slip Joint

  • 26

    The Administrative Authority must be notified at least ___ working days before such inspection is intended.

    3

  • 27

    Any pipe or fitting installed at an angle of more than 45 degrees with the vertical line.

    horizontal pipe

  • 28

    Which authority is responsible for the administration and enforcement of the National Plumbing Code?

    Plumbing Official

  • 29

    The top edge of a receptacle from where water overflows.

    Flood Level Rim

  • 30

    Elastomeric gasketed and rubber-ring joints shall comply with _____ installation standard

    IAPMO

  • 31

    ASTM means?

    American Society for Testing and Materials

  • 32

    For caulked-on closet ring, the minimum overall depth shall be:

    2"

  • 33

    Wiped lead joints shall have an exposed surface on each side of a joint not less than _____.

    19 mm

  • 34

    The year when NAMPAP was organized and registered with the Securities and Exchange Commission

    1935

  • 35

    All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application.

    6

  • 36

    What is the accreditation number of NAMPAP?

    14

  • 37

    Code on Sanitation of the Philippines

    PD 856

  • 38

    Common maximum service temperature rating of PVC

    140 deg. F

  • 39

    The following are grounds for non-issuance of the certificate of registration by the Board of Master Plumbers except for _____.

    failure to pay the required fees

  • 40

    Vertical support of _____ is placed not less than every other storey height.

    Screwed Pipe

  • 41

    Plumbing fixtures shall be made of smooth non-absorbent material, free from concealed fouling surfaces and shall be located in ventilated enclosures

    Principle No. 7

  • 42

    Trap arm size of Laundry Tub

    38 mm

  • 43

    IPS shall be supported at ___ intervals for piping 19 mm diameter and smaller.

    3 m

  • 44

    A pipe flange that is not drilled for bolt holes.

    blank flange

  • 45

    Integrated within an air accumulator vessel which is designed to discharge a predetermined quantity of water into fixtures for flushing purposes

    Flushometer Tank

  • 46

    The Old Fire Code of the Philippines

    PD 1185

  • 47

    A pipe or conduit for carrying sewage and wastewater .

    Sewer

  • 48

    Who is the current chairman of the Board of Examiners for Master Plumber?

    Reynald B. Ilagan

  • 49

    (ANSI) Pipe Color code for Fire Quenching

    Red with White Lettering

  • 50

    Any change, addition or modification in construction or occupancy

    Alteration