    Limit stops shall be adjusted to deliver hot water with a maximum temperature of _______.

    120 F

  • 2

    1 Kcal is how many BTU?

    3.965

  • 3

    What is the allowed depth of shower dam or threshold?

    2”-9”

  • 4

    Minimum pipe sizing for a branch serving a 400 DFU.

    127 mm

  • 5

    Clotheswashers in groups of 3 or more shall be rated at ___________ each for the common horiontal and vertical waste pipe sizing.

    6 FU

  • 6

    Trap arm size of a service sink

    51 mm

  • 7

    A large opening in a sewer line or part of a plumbing system constructed with sufficient size for a man to gain access therein for maintenance purposes

    manhole

  • 8

    An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding ________.

    90 deg

  • 9

    When a Public or Private Sewer is not available for use, excreta drainage piping from buildings and premises shall be connected to an approved ________.

    Private Sewage Disposal System

  • 10

    Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than ________.

    1033 kPa

  • 11

    Potable water shall use solders and fluxes with a lead content not exceeding _______.

    0.2%

  • 12

    Preferred pipe for transporting gas

    Black Steel Pipe

  • 13

    WSFU of a private hose bibb

    3

  • 14

    Medical gas piping is most often joined by _______.

    Silver Brazing

  • 15

    Which of the following fixture group qualifies the definition of battery of fixtures?

    5 water closets

  • 16

    A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____________.

    Bathub

  • 17

    What is the maximum Fixture unit loading of a 2" trap?

    4

  • 18

    AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the __________ with the critical level not less than ___________ above flood level rim.

    last valve; 152 mm

  • 19

    1 Water Closet and 1 Urinal must be provided for temporary workingmen facilities for each ________ workmen.

    30

  • 20

    Linings for showers shall not be nailed or perforated at any point less than _______ above the finished dam or threshold.

    1”

  • 21

    How many fixture units if equivalent to a 30 gpm-rated sump?

    60 FU

  • 22

    A valve opened and closed by the fall and rise, respectively, of an attached ball floating on the surface of the liquid.

    Ball Cock

  • 23

    Building Sewer or other drainage pipings must be installed not less than _________ within any building or structure.

    0.6 m

  • 24

    What is the maximum fixture loading of a 8" pipe sloped at 1%?

    2112

  • 25

    What is the Maximum DFU loading of a 102 mm horizontal branch?

    216

  • 26

    A standpipe having a remote control device at each hose station.

    Manually-Operated Standpipe System

  • 27

    A double check valve backflow preventer requires __________ minimum clearance at the bottom for maintenance.

    305 mm

  • 28

    Thickness of Continuous waste and fixture tailpiece- seamless drawn brass

    Gauge 20 (0.8 mm)

  • 29

    Water Closet provision for 300 females in Assembly Places for Public Use

    11

  • 30

    Threads per inch for pipe size of 13 mm diameter.

    14

  • 31

    Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least ________ larger than the _________ inlet.

    2 pipe sizes; largest side inlet

  • 32

    The public sewer may be considered not being available when a sewer is located more than _________ from any proposed building or exterior drainage facility.

    61 m

  • 33

    Consists of a body, a checking member, and an atmospheric opening.

    Atmospheric Vacuum Breaker

  • 34

    A _________ diameter circular basin shall be equivalent to 1 lavatory.

    457.2 mm

  • 35

    A pressure regulator must be installed if the local water service pressure is above _________.

    80 psi

  • 36

    A device installed in a drainage system to prevent reverse flow.

    Backwater Valve

  • 37

    Threads per inch of a 64 mm cleanout size

    8

  • 38

    Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _________ of mercury.

    0 to 63.5 cm

  • 39

    Galvanized wrought iron or galvanized steel pipe shall be kept __________________.

    150 mm above ground

  • 40

    Copper tubing shall be fully externally protected with a/an ________________ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.

    bitumastic coating

  • 41

    Color of Steam Division- High Pressure Pipe

    White

  • 42

    1 Laundry Tray must be provided per _____ persons.

    50

  • 43

    Each tailpiece, continuous waste or waste and overflow shall not be less than ______ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.

    38 mm O.D.

  • 44

    Which of the following can be drained through an air break?

    evaporative cooler

  • 45

    (ANSI) Pipe Color code for Fire Quenching

    Red with White Lettering

  • 46

    Code on Sanitation of the Philippines

    PD 856

  • 47

    Hanger rod size for 5" pipe size

    13 mm

  • 48

    Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _______.

    Bitumen

  • 49

    Backflow prevention device for a hose bibb

    Atmospheric Vacuum Breaker

  • 50

    The transference of heat by the upward movement of a warm light air current.

    Convection

  • YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 13日前

    YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    100問 • 13日前
    ユーザ名非公開

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 13日前

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    100問 • 13日前
    ユーザ名非公開

    Project Engineer YT 1

    Project Engineer YT 1

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer YT 1

    Project Engineer YT 1

    100問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM

    Project Engineer EXAM

    ユーザ名非公開 · 62問 · 13日前

    Project Engineer EXAM

    Project Engineer EXAM

    62問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    100問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    100問 • 13日前
    ユーザ名非公開

    July 2023 PE Refresher

    July 2023 PE Refresher

    ユーザ名非公開 · 70問 · 13日前

    July 2023 PE Refresher

    July 2023 PE Refresher

    70問 • 13日前
    ユーザ名非公開

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    ユーザ名非公開 · 93問 · 13日前

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    93問 • 13日前
    ユーザ名非公開

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    ユーザ名非公開 · 86問 · 13日前

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    86問 • 13日前
    ユーザ名非公開

    Plumbing Code 4

    Plumbing Code 4

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 4

    Plumbing Code 4

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 5

    Plumbing Code 5

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 5

    Plumbing Code 5

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 6

    Plumbing Code 6

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 6

    Plumbing Code 6

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 7

    Plumbing Code 7

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 7

    Plumbing Code 7

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 8

    Plumbing Code 8

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 8

    Plumbing Code 8

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 3

    Plumbing Code 3

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 3

    Plumbing Code 3

    100問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    ユーザ名非公開 · 97問 · 13日前

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    97問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    ユーザ名非公開 · 99問 · 13日前

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    99問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    ユーザ名非公開 · 96問 · 13日前

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    96問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    ユーザ名非公開 · 95問 · 13日前

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    95問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    ユーザ名非公開 · 97問 · 13日前

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    97問 • 13日前
    ユーザ名非公開

    問題一覧

  • 1

    Limit stops shall be adjusted to deliver hot water with a maximum temperature of _______.

    120 F

  • 2

    1 Kcal is how many BTU?

    3.965

  • 3

    What is the allowed depth of shower dam or threshold?

    2”-9”

  • 4

    Minimum pipe sizing for a branch serving a 400 DFU.

    127 mm

  • 5

    Clotheswashers in groups of 3 or more shall be rated at ___________ each for the common horiontal and vertical waste pipe sizing.

    6 FU

  • 6

    Trap arm size of a service sink

    51 mm

  • 7

    A large opening in a sewer line or part of a plumbing system constructed with sufficient size for a man to gain access therein for maintenance purposes

    manhole

  • 8

    An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding ________.

    90 deg

  • 9

    When a Public or Private Sewer is not available for use, excreta drainage piping from buildings and premises shall be connected to an approved ________.

    Private Sewage Disposal System

  • 10

    Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than ________.

    1033 kPa

  • 11

    Potable water shall use solders and fluxes with a lead content not exceeding _______.

    0.2%

  • 12

    Preferred pipe for transporting gas

    Black Steel Pipe

  • 13

    WSFU of a private hose bibb

    3

  • 14

    Medical gas piping is most often joined by _______.

    Silver Brazing

  • 15

    Which of the following fixture group qualifies the definition of battery of fixtures?

    5 water closets

  • 16

    A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____________.

    Bathub

  • 17

    What is the maximum Fixture unit loading of a 2" trap?

    4

  • 18

    AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the __________ with the critical level not less than ___________ above flood level rim.

    last valve; 152 mm

  • 19

    1 Water Closet and 1 Urinal must be provided for temporary workingmen facilities for each ________ workmen.

    30

  • 20

    Linings for showers shall not be nailed or perforated at any point less than _______ above the finished dam or threshold.

    1”

  • 21

    How many fixture units if equivalent to a 30 gpm-rated sump?

    60 FU

  • 22

    A valve opened and closed by the fall and rise, respectively, of an attached ball floating on the surface of the liquid.

    Ball Cock

  • 23

    Building Sewer or other drainage pipings must be installed not less than _________ within any building or structure.

    0.6 m

  • 24

    What is the maximum fixture loading of a 8" pipe sloped at 1%?

    2112

  • 25

    What is the Maximum DFU loading of a 102 mm horizontal branch?

    216

  • 26

    A standpipe having a remote control device at each hose station.

    Manually-Operated Standpipe System

  • 27

    A double check valve backflow preventer requires __________ minimum clearance at the bottom for maintenance.

    305 mm

  • 28

    Thickness of Continuous waste and fixture tailpiece- seamless drawn brass

    Gauge 20 (0.8 mm)

  • 29

    Water Closet provision for 300 females in Assembly Places for Public Use

    11

  • 30

    Threads per inch for pipe size of 13 mm diameter.

    14

  • 31

    Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least ________ larger than the _________ inlet.

    2 pipe sizes; largest side inlet

  • 32

    The public sewer may be considered not being available when a sewer is located more than _________ from any proposed building or exterior drainage facility.

    61 m

  • 33

    Consists of a body, a checking member, and an atmospheric opening.

    Atmospheric Vacuum Breaker

  • 34

    A _________ diameter circular basin shall be equivalent to 1 lavatory.

    457.2 mm

  • 35

    A pressure regulator must be installed if the local water service pressure is above _________.

    80 psi

  • 36

    A device installed in a drainage system to prevent reverse flow.

    Backwater Valve

  • 37

    Threads per inch of a 64 mm cleanout size

    8

  • 38

    Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _________ of mercury.

    0 to 63.5 cm

  • 39

    Galvanized wrought iron or galvanized steel pipe shall be kept __________________.

    150 mm above ground

  • 40

    Copper tubing shall be fully externally protected with a/an ________________ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.

    bitumastic coating

  • 41

    Color of Steam Division- High Pressure Pipe

    White

  • 42

    1 Laundry Tray must be provided per _____ persons.

    50

  • 43

    Each tailpiece, continuous waste or waste and overflow shall not be less than ______ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.

    38 mm O.D.

  • 44

    Which of the following can be drained through an air break?

    evaporative cooler

  • 45

    (ANSI) Pipe Color code for Fire Quenching

    Red with White Lettering

  • 46

    Code on Sanitation of the Philippines

    PD 856

  • 47

    Hanger rod size for 5" pipe size

    13 mm

  • 48

    Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _______.

    Bitumen

  • 49

    Backflow prevention device for a hose bibb

    Atmospheric Vacuum Breaker

  • 50

    The transference of heat by the upward movement of a warm light air current.

    Convection