  • 1

    What is the estimated sewage flow rate of bowling alleys with snack bar only?

    283.9 LpD per lane

  • 2

    What is the storage factor for self-service auto washers?

    1.5

  • 3

    Minimum dimension of a sand interceptor's inlet opening

    0.2 sq.m.

  • 4

    A group vent pipe that connects to the vent stack

    Circuit Vent

  • 5

    Prohibited vent pipe material below ground

    Galvanized Wrought Iron

  • 6

    Minimum spacing between trenches or leaching beds

    1.20 m

  • 7

    Which among the choices is a prohibited trap?

    Crown trap

  • 8

    Normally in Manila, the rainfall intensity used is _____.

    102 mm

  • 9

    Maximum number of slip joint fitting that may be used on the outlet side of a trap

    1

  • 10

    Wet venting is limited to ______ fixtures

    4

  • 11

    Maximum length of a tailpiece

    0.6 m

  • 12

    What is an underground drain pipe that receives only sub-surface or seepage water and convey it to a sump for disposal by gravity flow or by lift pump?

    subsoil drain

  • 13

    Connects directly with an individual trap underneath or behind the fixture

    Backvent Pipe

  • 14

    What can be drained through an airbreak?

    air washer

  • 15

    The size of a vent pipe is determined by __________.

    FU and length

  • 16

    In getting the roof area for the computation of rainwater piping size, for two walls opposite of differing heights, add _______ of wall area above top of lower wall to the roof area.

    50%

  • 17

    Elastomeric gasketed and rubber-ring joints shall comply with _________ installation standard

    IAPMO

  • 18

    The minimum inlet and outlet size for sand interceptor

    76 mm

  • 19

    What is the maximum length allowed for a vent stack serving 48 DFU?

    55

  • 20

    For accessible toilets, signs on walls and doors should be located at a maximum height of _______.

    1.60 m

  • 21

    What is the horizontal distance required of a vent pipe from any openable window, door opening, air intake, or vent shaft?

    3 m

  • 22

    The maximum trap loading of a pipe size 76 mm

    6

  • 23

    Vertical vent pipes installed in a roof used for other purposes shall extend a minimum of ________ above such roof.

    2.1 m

  • 24

    If a septic tank can have an effective capacity of 4000 L, how much does the secondary compartment hold?

    1,333 L

  • 25

    The principal artery of the venting system to which vent branches are connected.

    Main Vent

  • 26

    The bottom of the water pipe, at all points shall be at least _________ above the top of the sewer or drain line.

    0.3 m

  • 27

    What is the minimum distance from disposal field to another disposal field?

    1.2 m

  • 28

    What is the sewage that turns dark and smell unpleasantly due to anaerobic decomposition?

    septic

  • 29

    Determine the size of horizontal rainwater piping with a slope of 2% for a 350 sqm roof in an area where the the rainfall is 102 mm/hr.

    127 mm

  • 30

    When the first compartment exceeds 3.7 m in length, an additional ________ shall be provided.

    manhole

  • 31

    Rainwater piping located within a medium height building basement area shall be of Galvanized Iron _______.

    Schedule 30

  • 32

    What will be the size of 0.5% sloped circular bottom gutter serving a roof area of 180 sqm, and the rainfall intensity around the area is 76 mm/hr?

    178 mm

  • 33

    What downspout size would you specify for an 800 sqm roof with a rainfall intensity around the area of 152.4 mm/hr?

    152 mm

  • 34

    Minimum distance of a 32 mm trap arm diameter to a vent

    64 mm

  • 35

    The minimum depth of the sand interceptor under the invert of the outlet pipe is ________.

    610 mm

  • 36

    The side walls of a Septic Tank shall be at least __________ above the liquid depth.

    9”

  • 37

    All condensers and sumps shall be properly trapped at the outlet with a deep seal trap extending to within _________ of the bottom of the tank.

    6”

  • 38

    A 203 mm diameter and larger sewer may have a slope of _________.

    0.5%

  • 39

    In a granule test of a water closet, the initial flush of three different flushes must result in no more than ___________ on average remaining in the bowl.

    125

  • 40

    What is the minimum condensate pipe diameter of a cooling equipment with capacity through 125 ToR?

    38 mm

  • 41

    A water that stands in or passes through the ground

    Ground Water

  • 42

    Jointing method for soft copper water tubing

    Flared Joint

  • 43

    What is required when a soil or waste stack extends 10 or more stories?

    Parallel Vent Stack

  • 44

    Minimum water seal of a grease trap

    51 mm

  • 45

    Septic tanks should be cleaned when scum or sludge occupies ________ of the tank volume.

    1/3

  • 46

    Every abandoned building sewer shall be plugged or capped within __________ of the property line.

    1.5 m

  • 47

    Water closets that are made to accommodate overweight and obese people

    Bariatic Water Closet

  • 48

    _________ are recommended for oil handling piping works.

    Neoprene Gaskets

  • 49

    Horizontal distance of the trap arm with a diameter of 38 mm

    1.07 m

  • 50

    What is the gauge pressure to be maintained for air tests as substitute for water test in water pipings?

    344.5 kPa

  • YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 13日前

    YT1 Materials Engineer EXAM

    YT1 Materials Engineer EXAM

    100問 • 13日前
    ユーザ名非公開

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    ユーザ名非公開 · 100問 · 13日前

    YT2 Materials Engineer EXAM

    YT2 Materials Engineer EXAM

    100問 • 13日前
    ユーザ名非公開

    Project Engineer YT 1

    Project Engineer YT 1

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer YT 1

    Project Engineer YT 1

    100問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM

    Project Engineer EXAM

    ユーザ名非公開 · 62問 · 13日前

    Project Engineer EXAM

    Project Engineer EXAM

    62問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer EXAM 68

    Project Engineer EXAM 68

    100問 • 13日前
    ユーザ名非公開

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    ユーザ名非公開 · 100問 · 13日前

    Project Engineer EXAM 82

    Project Engineer EXAM 82

    100問 • 13日前
    ユーザ名非公開

    July 2023 PE Refresher

    July 2023 PE Refresher

    ユーザ名非公開 · 70問 · 13日前

    July 2023 PE Refresher

    July 2023 PE Refresher

    70問 • 13日前
    ユーザ名非公開

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    ユーザ名非公開 · 93問 · 13日前

    August 2019 Special PE Exam

    August 2019 Special PE Exam

    93問 • 13日前
    ユーザ名非公開

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    ユーザ名非公開 · 86問 · 13日前

    RNPCP Chapter 1 to 5

    RNPCP Chapter 1 to 5

    86問 • 13日前
    ユーザ名非公開

    Plumbing Code 4

    Plumbing Code 4

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 4

    Plumbing Code 4

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 5

    Plumbing Code 5

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 5

    Plumbing Code 5

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 6

    Plumbing Code 6

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 6

    Plumbing Code 6

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 7

    Plumbing Code 7

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 7

    Plumbing Code 7

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 8

    Plumbing Code 8

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 8

    Plumbing Code 8

    100問 • 13日前
    ユーザ名非公開

    Plumbing Code 3

    Plumbing Code 3

    ユーザ名非公開 · 100問 · 13日前

    Plumbing Code 3

    Plumbing Code 3

    100問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    ユーザ名非公開 · 97問 · 13日前

    Sanitation, Plumbing Design, and Installation 2

    Sanitation, Plumbing Design, and Installation 2

    97問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    ユーザ名非公開 · 99問 · 13日前

    Sanitation, Plumbing Design, and Installation 1

    Sanitation, Plumbing Design, and Installation 1

    99問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    ユーザ名非公開 · 96問 · 13日前

    Sanitation, Plumbing Design, and Installation 3

    Sanitation, Plumbing Design, and Installation 3

    96問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    ユーザ名非公開 · 95問 · 13日前

    Sanitation, Plumbing Design, and Installation 4

    Sanitation, Plumbing Design, and Installation 4

    95問 • 13日前
    ユーザ名非公開

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    ユーザ名非公開 · 97問 · 13日前

    Sanitation, Plumbing Design, and Installation 5

    Sanitation, Plumbing Design, and Installation 5

    97問 • 13日前
    ユーザ名非公開

    問題一覧

  • 1

    What is the estimated sewage flow rate of bowling alleys with snack bar only?

    283.9 LpD per lane

  • 2

    What is the storage factor for self-service auto washers?

    1.5

  • 3

    Minimum dimension of a sand interceptor's inlet opening

    0.2 sq.m.

  • 4

    A group vent pipe that connects to the vent stack

    Circuit Vent

  • 5

    Prohibited vent pipe material below ground

    Galvanized Wrought Iron

  • 6

    Minimum spacing between trenches or leaching beds

    1.20 m

  • 7

    Which among the choices is a prohibited trap?

    Crown trap

  • 8

    Normally in Manila, the rainfall intensity used is _____.

    102 mm

  • 9

    Maximum number of slip joint fitting that may be used on the outlet side of a trap

    1

  • 10

    Wet venting is limited to ______ fixtures

    4

  • 11

    Maximum length of a tailpiece

    0.6 m

  • 12

    What is an underground drain pipe that receives only sub-surface or seepage water and convey it to a sump for disposal by gravity flow or by lift pump?

    subsoil drain

  • 13

    Connects directly with an individual trap underneath or behind the fixture

    Backvent Pipe

  • 14

    What can be drained through an airbreak?

    air washer

  • 15

    The size of a vent pipe is determined by __________.

    FU and length

  • 16

    In getting the roof area for the computation of rainwater piping size, for two walls opposite of differing heights, add _______ of wall area above top of lower wall to the roof area.

    50%

  • 17

    Elastomeric gasketed and rubber-ring joints shall comply with _________ installation standard

    IAPMO

  • 18

    The minimum inlet and outlet size for sand interceptor

    76 mm

  • 19

    What is the maximum length allowed for a vent stack serving 48 DFU?

    55

  • 20

    For accessible toilets, signs on walls and doors should be located at a maximum height of _______.

    1.60 m

  • 21

    What is the horizontal distance required of a vent pipe from any openable window, door opening, air intake, or vent shaft?

    3 m

  • 22

    The maximum trap loading of a pipe size 76 mm

    6

  • 23

    Vertical vent pipes installed in a roof used for other purposes shall extend a minimum of ________ above such roof.

    2.1 m

  • 24

    If a septic tank can have an effective capacity of 4000 L, how much does the secondary compartment hold?

    1,333 L

  • 25

    The principal artery of the venting system to which vent branches are connected.

    Main Vent

  • 26

    The bottom of the water pipe, at all points shall be at least _________ above the top of the sewer or drain line.

    0.3 m

  • 27

    What is the minimum distance from disposal field to another disposal field?

    1.2 m

  • 28

    What is the sewage that turns dark and smell unpleasantly due to anaerobic decomposition?

    septic

  • 29

    Determine the size of horizontal rainwater piping with a slope of 2% for a 350 sqm roof in an area where the the rainfall is 102 mm/hr.

    127 mm

  • 30

    When the first compartment exceeds 3.7 m in length, an additional ________ shall be provided.

    manhole

  • 31

    Rainwater piping located within a medium height building basement area shall be of Galvanized Iron _______.

    Schedule 30

  • 32

    What will be the size of 0.5% sloped circular bottom gutter serving a roof area of 180 sqm, and the rainfall intensity around the area is 76 mm/hr?

    178 mm

  • 33

    What downspout size would you specify for an 800 sqm roof with a rainfall intensity around the area of 152.4 mm/hr?

    152 mm

  • 34

    Minimum distance of a 32 mm trap arm diameter to a vent

    64 mm

  • 35

    The minimum depth of the sand interceptor under the invert of the outlet pipe is ________.

    610 mm

  • 36

    The side walls of a Septic Tank shall be at least __________ above the liquid depth.

    9”

  • 37

    All condensers and sumps shall be properly trapped at the outlet with a deep seal trap extending to within _________ of the bottom of the tank.

    6”

  • 38

    A 203 mm diameter and larger sewer may have a slope of _________.

    0.5%

  • 39

    In a granule test of a water closet, the initial flush of three different flushes must result in no more than ___________ on average remaining in the bowl.

    125

  • 40

    What is the minimum condensate pipe diameter of a cooling equipment with capacity through 125 ToR?

    38 mm

  • 41

    A water that stands in or passes through the ground

    Ground Water

  • 42

    Jointing method for soft copper water tubing

    Flared Joint

  • 43

    What is required when a soil or waste stack extends 10 or more stories?

    Parallel Vent Stack

  • 44

    Minimum water seal of a grease trap

    51 mm

  • 45

    Septic tanks should be cleaned when scum or sludge occupies ________ of the tank volume.

    1/3

  • 46

    Every abandoned building sewer shall be plugged or capped within __________ of the property line.

    1.5 m

  • 47

    Water closets that are made to accommodate overweight and obese people

    Bariatic Water Closet

  • 48

    _________ are recommended for oil handling piping works.

    Neoprene Gaskets

  • 49

    Horizontal distance of the trap arm with a diameter of 38 mm

    1.07 m

  • 50

    What is the gauge pressure to be maintained for air tests as substitute for water test in water pipings?

    344.5 kPa