記憶度
15問
35問
0問
0問
0問
アカウント登録して、解答結果を保存しよう
問題一覧
1
In plumbing systems, if pipes are electrical wires, what are equivalent to switches?
valve
2
Mininum size of trap and waste branch for pedestal urinal
3"
3
What type of materials is used for the base of septic tank?
reinforced concrete
4
What is the color pipes for steam
white
5
Black steel pipe with galvanized malleable fittings is ideal for:
gas pipe
6
Chemical used for checking the growth of algae in reservoir
copper sulphate
7
The proper fall for a house sewer is established by:
establishing a grade line then digging the trench exactly this line
8
A drain connecting one or more fixtures to a solid or waste stack
combined drain
9
In a building drainage system, what is a definition of a stack?
Vertical pipe of a system of soil, waste or vent piping that extends through one or more stories
10
Where should a grease trap be installed?
As close to the fixture as possible, preferably inside the building
11
Which is not a rule of thumb when designing a drainage?
It should be underneath the driveway
12
What is the greatest stress which a material can stand without permanent deformation after release of stress?
tensile stress
13
What is the color coding for pipes for potable water
blue
14
A caulked joint shall be firmly packed with oakum or hemp and powder received with pure lead, what is the depth of lead over aukum?
25mm
15
Can you embed a 4" pipe in a 150 CHB wall?
No
16
How do we size sewage pits?
Volume of liquid and solid waste
17
What type of sink is used for dumping mop buckets and washing mops?
service sinks
18
What is used to determine the size of the stack after the fixture unit values have been totaled?
stack table
19
Part per million is identical to:
milligrams per kg
20
Minimum distance of a well from a septic tank
15.2m
21
Where do you locate water distribution pipe farthest from?
large trees
22
What should not be permitted to cross a beam?
soil pipe
23
When water goes up through a vertical pipe, it stops at a certain height. Why?
The pressure inside the pipe equates to the pressure outside the pipe causing the water to stop at that point where it appears
24
Per capita consumption of water is generally taken as:
50-100 liters
25
Which antifreeze solution should be your first choice when you are protecting fixture traps against freezing?
glycol
26
Is a receptacle used to catch surface water drained from cemented courts, driveways, and yards.
yards catch basin
27
A device used in conjuction with a fixture such as water closet and urinal which discharges a pre-determined quantity of water for flushing purposes. This device is actuated by direct water pressure from branch pipes.
flushometer valve
28
When there is a low pressure from the water main, what will you use to supply higher levels?
booster pump
29
Fixture unit value of bathtub
2
30
A domestic food grinder is designed to attach to drain with a diameter of:
1 1/2"
31
What part of the body-unit faucet virtually eliminates maintenance of the faucet under normal operations?
ceramic component
32
What is the water depth of a common seal trap
2"
33
What type of end connection are used for valves smaller than 2" diameter?
threaded
34
Best location to put the soil pipe
pipe chase
35
Water well yield is a factor considered in determining the size of:
water pipe
36
When specifications is not available, install the urinal so the lip height is:
20-25" above the finished floor line
37
The basic elements of a cold water supply include the:
riser run-out
38
Tank water closets are preferred over flushometer water closets for residences because they:
require smaller size supply
39
The code that prescribes criteria on the quality of drinking water from meteoric, surface or underground sources is:
National Standards for Drinking Water
40
In high rise buuldings, why is there a need to resize water supply pipes?
To use up the difference in pressure from the service to the supply fixtures
41
In preparing a mortar for a cement joint, the mixture will be:
one part cement, one part sand and water
42
How do you repair a leak on a plastic pipe fitting?
Cut fitting out and install new fitting
43
When winterizing the system, what is the first step in draining a water system?
Close the main shutoff valve
44
Alternative to the conventional septic tank:
aerobic treatment system
45
In a water distribution system, what connects the water main to the water risers
riser run-out
46
Best for sanitary pipes
UPVC
47
Fixture outlets shall not be connected to the horizontal drainage within ______ of any vertical to horizontal change of direction of a stack containing suds producing fixtures.
2.4m
48
What is the name of the special tool designed to reach the hex jam nut beneath a fixture?
basin wrench
49
What may happen if a sewer pipes is laid with a fall greater than 1/4 inch per foot (2%)?
Waste water runs away from solids, eventually causing stoppages
50
Which type of lavatory is designed for group use?
countertop
51
A fibrous silicate material that is inert, strong, and incombustible
asbestos
52
It is caused by foreign objects like string or thread suspended over outlet arm of the trap
capillarity action
53
When installing a compression coupling, why do you dig out the area to give you as much flexibility with the pipes?
To allow easier installation
54
What is corresponding name of the following abbreviation pertaining to local trade and government regulating body
DTI
55
The building sewer is usually made of clay tile, cast iron, asbestos cement and:
plastic pipe
56
What is the best fixture for a public comfort room?
flushometer
57
What type of drainage piping only conveys liquids that are free of fecal matter?
waste
58
FU of laundry tub
2
59
What is installed on fixtures to keep sewer gasses from entering the building?
traps
60
Chemical drain cleaners are appropriate when drains are:
flowing sluggishly
61
What is the proper way to tighten bolts on a full circle clamp?
Working from the center out
62
Revised Fire Code of the Philippines
RA 9514
63
All dry standpipe shall extend from the ground floor and over the roof and shall be equipped with 64mm outlet in every floor level with a minimum height of:
1.2m
64
What should you do if an oxygen deficient condition is present in a manhole?
Ventilate it or use self contained breathing appratus
65
For best result how should you backfill a trench?
Backfill in layers or not more than 4" and tamp with mechanical tamper
66
What is the proper length of time and velocity for flushing a main?
30min/2.5fps
67
In constructing a sewer main, when should you backfill the trench?
after you inspect the pipe
68
Which of the following is not a type of lavatory?
reverse trap
69
Minimum clearance from the floor of pipes for AC units when crossing a hallway or corridor
2.3m
70
Swimming pool needs:
de-chlorination
71
FU for shower bath
2
72
Size of water supply line for urinal flushometer
19mm
73
In storm drainage system, it is used to prevent aggregates, debris and other unwanted objects from entering the drainage system
catch basin
74
If a faucet closes with the pressure; not against it, the result is:
easier operation and tighter seal
75
Smallest plastic drain that can accummodate a water closet
38mm or 1 1/2"
76
What is the smallest plastic drain that can accommodate a water closet
76mm or 3"
77
What do you call a control valve used to shutoff at the water supply to a building in case of emergency? It is installed at a water service pipe and operated by means of long key inserted through a curb box?
curb cock/stop
78
A system of vertical pipes in a building to which fire hoses can be attached on each floor, including a system by which water is made available to the outlets as needed.
standpipe
79
Where will you least place a downspout?
inside columns
80
What should not be used for a pipe chase
drywall
81
The water service is a pipe that extends from the:
water main to the water meter
82
In which order is a water main disinfected?
flushing, dosing, flushing, testing
83
The unobstructed vertical distance through the free atmosphere between the outlet of water pipe and the flood level rim of the receptacle into which it is charging
air gap
84
Mininum size of trap and waste branch for a bidet
51mm or 2"
85
Ball valves are adaptation of:
plug valves
86
There is a septic tank installed on top of a rock by seashore. The tank is exposed on how tide and covered in sea water during high tide. Which of the following woupd be an appropriate water proofing for it?
waterproof all surfaces
87
WSFU for stall and wall urinal
5
88
Clean Water Act
RA 9275
89
Where are storm sewer usually placed?
near the curb
90
The spoon like tools use for pouring molted pig lead into hub as making caulk joint in cast iron pipe is called:
scoop
91
Take advantage of a salaried ________ position to compete unfairly with a practicing Master Plumber.
government
92
Aeration is water is done for all of the following purposes except for
removal of temporary hardness
93
In PD 856 Sanitation Code of the Philippines, the effective depth of a septic tank is measured from the bottom of septic tank to the _______.
liquid line
94
What type of repair clamp should be used as a temporary repair
compression coupling
95
What is the minimum sized pipe that you could use on wet vent?
51mm or 2"
96
Clean Air Act
RA 8749
97
Which is the common practice to reduce the danger of breakage which may result from expansion and contraction of roof?
provide the end of roof leader with flexible material
98
A drinking fountain bubbler opening should be located above the drinking fountain rim a minimum of:
25mm or 1"
99
Heavy water is:
D20
100
Provincial Water Utilities Act
PD 198