問題一覧
1
Minimum thickness of walls and bottom of sumps, condensers or intercepting tanks constructed of concrete
102mm (4")
2
Mininum size of water service pipe
19mm
3
Maximum number of fixtures can be served by a vertical wet vent.
4
4
Minimum thickness of metal condensers
GA 12 (2.77mm)
5
Yoke vent connection with the vent stack above the floor level
not more than 1m
6
1 inlet serving 4-12 cu.m of refrigeration space
51mm (2")
7
Mininum installation height of listed non removable hose bibb type backflow preventer above the highest point of usage.
152mm
8
Aggregate offset angle to be provided with an additional cleanout
135° or more
9
Horizontal distance of a vent opening away from any lot line, alley, and street boundary lines
0.90m or 3'
10
Vertical extension of a vent above any roof that is used for other purposes.
2.1m
11
Connection of the returned vent for island fixtures to the horizontal drain above the flood level rim
152mm (6")
12
For condensers and sumps, the extension of the deep seal trap within the bottom of the trap
152mm (6")
13
Number of mesh per 25mm for gravity tanks vent screen
14 to 18
14
Maximum temperature allowed for water to be discharged under pressure directly into the drainage system
60°C (140°F)
15
For condensers and sumps, diameter of the opening serving as siphon breaker at the top of the deep seal trap.
19mm (3/4")
16
Mininum distance of Double Check Valve (DC) assembly above all downstream piping and floor level rim of receptor
30.5cm
17
Support trap arms more than _____ in length shall be as close as possible
3' or 914mm
18
Number of water closets or 6 fixture unit traps allowed on any vertical stack
4
19
Minimum temperature of the AVB critical pevel above overflow rim of a water closet bowl or the highest part of a urinal
43.3°C (110°F)
20
Horizontal clearance from the means of access for cleanouts installed in underground piping
0.75m
21
Minimum size of an individual vent
32mm or 1 1/4"
22
Minimum diameter of indirect waste pipe
13mm or 1/2"
23
Maximum distance of unions away from regulating equipment, water heater, conditioning tank, or similar.
0.30m
24
Front clearance for cleanouts 51mm or less
305mm or 12"
25
Minimum size of building supply and branches
13mm
26
Distance between bottom of water pipe and top of the sewer or drain line
0.30m
27
Fixture rating of clotheswasher in groups of 3
6 FU
28
Mininum height of ballcock's critical level above the full opening of the overflow pipe
25mm
29
Minimum thickness of chemical-resistant glass lined pipe, high silicon iron pipe or lead pipe receiving acid or corrosive chemicals.
3.2mm
30
Minimum size of waste pipe and trap in any CW & VS, in reference to the sizes required and tailpiece size
2 pipe size larger
31
Minimum clearance of a vent through the roof from any vertical surface nearby.
0.30m or 12"
32
Minimum size of vent for sumps and receiving tanks
51mm or 2"
33
Front clearance for cleanouts more than 51mm
450mm or 18"
34
Minimum size of wet vent
1 pipe size larger or 51mm
35
Cleanouts may not be required on any wet-vented branch serving a single trap when the fixture tailpiece or connection is larger than ___
51mm (2")
36
Maximum intervals of piping supports
4' or 1219mm
37
Intervals of cleanouts on each run of piping
15m
38
May be served by a common vertical vent
2 fixtures
39
Length of horizontal drain line where cleanouts maybe omitted, except in lines serving sinks or urinals.
< 1.5m
40
Length of indirect waste pipe to be directly trapped but no need to be vented
1.5m to 4.6m (5' to 15')
41
Airgap less than 25mm shall only be approved if tested with vacuums of mercury from 0 to ____
63.5cm
42
Minimum area of CW & VS vent
1/2 the area of drain
43
Minimum airgap for water distribution, or a mininum of 2x diameter
25mm
44
1 inlet serving 13-36 cu.m of refrigeration space
76mm (3")
45
Mininum space clearance between the lowest portion of the assembly and the grade, floor or platform for access and clearance
30.5cm
46
Distance between sewer or drainage piping and water pipes crossing above such pipes
0.30m
47
1 inlet serving not more than 2.8 cu.m refrigeration space
32mm (1 1/4")
48
Maximum pressure setting for pressure relief valve
1033 kPa
49
Minimum distance of the invert of the lowest inlet above the high water or starting level of sumps and receiving tanks
51mm or 2"
50
Fixture unit rating for every 0.063 L/s (1gpm) of contiuous flow from sump pump or ejector
2 FU
51
Distance within the vertical to horizontal change of a stack containing suds producing fixtures where no drainage connection shall be made
2.4
52
Minimum depth of vitrified clay pipes or fittings below the ground
0.3m
53
Minimum diameter of individual vent, or not less than 1/2 of the diameter of the drain
32mm or 1 1/4"
54
Slope of horizontal drainage pipe where cleanouts may be omitted
72° or less
55
Intervals of yoke vent
every 5 floors
56
Excessive water pressure is more than:
551kPa
57
Extension of standpipe receptor of clotheswasher above its pipe
0.45m to 0.8m (16" to 30")
58
Each soil or waste stack which extends _____ or more stories above the building drain shall be served by a parallel vent stack
10
59
Allowable grades for the threads of drainage fittings
2%
60
Minimum thickness of plaster on the inside walls of sumps and condensers, etc
13mm (1/2")
61
Height of trap of clotheswasher standpipe receptor above the floor
0.15m to 0.45m (6" to 16")
62
Minimum air gap for fixtures affected by sidewalls
3x diameter
63
Minimum extension of a vent pipe above the roof or firewall
0.15m or 6"
64
In CW & VS, length of branch that must be separately vented.
more than 4.6m
65
Vertical distance of a vent opening above any openable window, door opening, air intake, or vent shaft
0.90m or 3'
66
Minimum height of the AVB critical level above the overflow rim of a water closet bowl or the highest part of a urinal
152mm
67
Outlets shall be taken off from the side in a manner to allow a water line to be maintained that permanently occupies not less than ___ the capacity of the condensers or sump.
1/2
68
Number of water closets or 6 fixture unit traps allowed on any horizontal branch or drain
3
69
Minimum air pressure to be maintained for each meter of height the sewage is raised
3 kg/m
70
Minimum clearance of galvanized wrought iron or galvanized steel pipe above ground
152mm or 6"
71
Minimum size of pump discharge pipe from a sump having a water closet
51mm or 2"
72
Closet rings shall be tightly fastened up to the floor with top surface _____ above finish floor.
1/4"
73
Fixture unit limit for wet venting
2FU
74
Minimum rise of each vent above the highest flood level rim before offsetting horizontally to join the vent stack or stack vent
152mm (6")
75
Percentage of reduced pressure used for all pipe size determination
80%
76
Fraction of the total permitted length of any vent allowed to be installed in a horizontal position
1/3
77
Minimum size of an individual vent but not less than 32 mm
1/2 the diameter
78
Maximum length of tailpiece
0.6m
79
Maximum lead content for water pipes and fittings
8%
80
Length of indirect waste pipe if diameter is less than the drain outlet or tailpiece
<4.6m
81
Horizontal distance of a vertical vent away from any part of the roof that is used for other purposes
3m
82
Inadequate water pressure is less than:
103kPa
83
Height of the drain pipe of pressure relief valve above the ground and pointing downward
152mm to 600mm
84
Size of iron cast fittings to be galvanized when used in water piping
51mm or smaller
85
Minimum distance of Atmospheric Vacuum Breaker (AVB) above all downstream piping and floor level rim of receptor
150mm or 6"
86
Increase in size of vent stack above the reconnection point of stack and horizontal vent
1 pipe size
87
Horizontal distance between the water line and the sewer or drain line
0.30m
88
Horizontal distance of a vent opening away from any openable window, door opening, air intake, or vent shaft
3m
89
Fraction of the total permitted length of any vent allowed to be installed in a horizontal position
1/3
90
Elevation of installations above the floor or grade to be provided with a permanent platform.
1.52m or 5'
91
Sumps and condensers shall contain a volume of not less than twice the volume of water removed from the boiler connected thereto when the normal water level is reduced not less than ___
102mm (4")
92
Vertical clearance from the means of access for cleanouts installed in underground piping
0.45m
93
Maximum distance of underfloor cleanout from an access door, trap door or crawl hole.
6.1m
94
Minimum air gap for fixtures not affected by sidewalls
2x diameter