ログイン

Physics Chapter 37
20問 • 1年前
  • ユーザ名非公開
  • 通報

    問題一覧

  • 1

    Patient dose from diagnostic x-rays is most often reported in ______.

    entrance skin dose

  • 2

    Patient skin exposure can be measured indirectly by using a _______.

    nomogram

  • 3

    If the radiographic technique for a KUB calls for 40 mAs, what is the ESD when the output intensity is 0.075 mGy/mAs?

    3 mGy

  • 4

    Acute skin effects from radiation exposure have been reported following ______ exams.

    angio/interventional

  • 5

    For the average fluoroscopy exam the ESE is _______.

    40 mGy/min.

  • 6

    An estimation of patient dose is reported as ______.

    ESE, bone marrow dose and gonadal dose

  • 7

    Bone marrow dose is measured _______.

    as an estimate from ESE

  • 8

    The most important variable in determining x-ray dose are the ______.

    receptor speed

  • 9

    The simplest way to measure patient dose is to measure the _________.

    entrance skin dose

  • 10

    The radiation dose monitor most frequently used to measure patient exposure is the _______.

    thermoluminescent dosimeter

  • 11

    If the output intensity of an x-ray machine is 0.064 mGy/mAs at 80 kVp, what is the patient’s ESE for an exam done at 20 mAs at 80 kVp?

    1.28 mGy

  • 12

    The approximate average bone marrow dose to the population of the United States is

    1

  • 13

    The genetically significant dose for the general public is important because of the risk of

    effects on the gene pool

  • 14

    The genetically significant dose (GSD) for the population of the United States is about

    0.20 mSv.

  • 15

    The mean marrow dose from diagnostic x-ray examinations averaged over the entire population of the United States is about

    100 mrad/yr.

  • 16

    The radiation dose absorbed by an organ such as bone marrow

    cannot be measured by a direct method; it can only be estimated.

  • 17

    Dose area product is expressed in which units?

    mGya-cm2

  • 18

    Which of the following procedures has caused the most sentinel events?

    Cardiac catheterization

  • 19

    The half-value layer (HVL) of projection x-rays in soft tissue is approximately how many centimeters?

    4 cm

  • 20

    Mean marrow dose (MMD) is defined as

    the average radiation dose to the entire active bone marrow.

  • Physics Chapter 1

    Physics Chapter 1

    ユーザ名非公開 · 19問 · 1年前

    Physics Chapter 1

    Physics Chapter 1

    19問 • 1年前
    ユーザ名非公開

    Physic Chapter 7

    Physic Chapter 7

    ユーザ名非公開 · 20問 · 1年前

    Physic Chapter 7

    Physic Chapter 7

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 8

    Physics Chapter 8

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 8

    Physics Chapter 8

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 9

    Physics Chapter 9

    ユーザ名非公開 · 21問 · 1年前

    Physics Chapter 9

    Physics Chapter 9

    21問 • 1年前
    ユーザ名非公開

    Physics Chapter 10

    Physics Chapter 10

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 10

    Physics Chapter 10

    20問 • 1年前
    ユーザ名非公開

    Physic Chapter 15

    Physic Chapter 15

    ユーザ名非公開 · 20問 · 1年前

    Physic Chapter 15

    Physic Chapter 15

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 16

    Physics Chapter 16

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 16

    Physics Chapter 16

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 22

    Physics Chapter 22

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 22

    Physics Chapter 22

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 25

    Physics Chapter 25

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 25

    Physics Chapter 25

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 35

    Physics Chapter 35

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 35

    Physics Chapter 35

    20問 • 1年前
    ユーザ名非公開

    Physics Chapter 40

    Physics Chapter 40

    ユーザ名非公開 · 20問 · 1年前

    Physics Chapter 40

    Physics Chapter 40

    20問 • 1年前
    ユーザ名非公開

    Positioning Chapter 1

    Positioning Chapter 1

    ユーザ名非公開 · 35問 · 1年前

    Positioning Chapter 1

    Positioning Chapter 1

    35問 • 1年前
    ユーザ名非公開

    Positioning Chapter 2

    Positioning Chapter 2

    ユーザ名非公開 · 100問 · 1年前

    Positioning Chapter 2

    Positioning Chapter 2

    100問 • 1年前
    ユーザ名非公開

    Positioning Chapter 3

    Positioning Chapter 3

    ユーザ名非公開 · 88問 · 1年前

    Positioning Chapter 3

    Positioning Chapter 3

    88問 • 1年前
    ユーザ名非公開

    Positioning Chapter 4

    Positioning Chapter 4

    ユーザ名非公開 · 31問 · 1年前

    Positioning Chapter 4

    Positioning Chapter 4

    31問 • 1年前
    ユーザ名非公開

    Positioning Chapter 5

    Positioning Chapter 5

    ユーザ名非公開 · 93問 · 1年前

    Positioning Chapter 5

    Positioning Chapter 5

    93問 • 1年前
    ユーザ名非公開

    Positioning Chapter 6

    Positioning Chapter 6

    ユーザ名非公開 · 55問 · 1年前

    Positioning Chapter 6

    Positioning Chapter 6

    55問 • 1年前
    ユーザ名非公開

    Positioning Chapter 7

    Positioning Chapter 7

    ユーザ名非公開 · 50問 · 1年前

    Positioning Chapter 7

    Positioning Chapter 7

    50問 • 1年前
    ユーザ名非公開

    問題一覧

  • 1

    Patient dose from diagnostic x-rays is most often reported in ______.

    entrance skin dose

  • 2

    Patient skin exposure can be measured indirectly by using a _______.

    nomogram

  • 3

    If the radiographic technique for a KUB calls for 40 mAs, what is the ESD when the output intensity is 0.075 mGy/mAs?

    3 mGy

  • 4

    Acute skin effects from radiation exposure have been reported following ______ exams.

    angio/interventional

  • 5

    For the average fluoroscopy exam the ESE is _______.

    40 mGy/min.

  • 6

    An estimation of patient dose is reported as ______.

    ESE, bone marrow dose and gonadal dose

  • 7

    Bone marrow dose is measured _______.

    as an estimate from ESE

  • 8

    The most important variable in determining x-ray dose are the ______.

    receptor speed

  • 9

    The simplest way to measure patient dose is to measure the _________.

    entrance skin dose

  • 10

    The radiation dose monitor most frequently used to measure patient exposure is the _______.

    thermoluminescent dosimeter

  • 11

    If the output intensity of an x-ray machine is 0.064 mGy/mAs at 80 kVp, what is the patient’s ESE for an exam done at 20 mAs at 80 kVp?

    1.28 mGy

  • 12

    The approximate average bone marrow dose to the population of the United States is

    1

  • 13

    The genetically significant dose for the general public is important because of the risk of

    effects on the gene pool

  • 14

    The genetically significant dose (GSD) for the population of the United States is about

    0.20 mSv.

  • 15

    The mean marrow dose from diagnostic x-ray examinations averaged over the entire population of the United States is about

    100 mrad/yr.

  • 16

    The radiation dose absorbed by an organ such as bone marrow

    cannot be measured by a direct method; it can only be estimated.

  • 17

    Dose area product is expressed in which units?

    mGya-cm2

  • 18

    Which of the following procedures has caused the most sentinel events?

    Cardiac catheterization

  • 19

    The half-value layer (HVL) of projection x-rays in soft tissue is approximately how many centimeters?

    4 cm

  • 20

    Mean marrow dose (MMD) is defined as

    the average radiation dose to the entire active bone marrow.