  • 1

    Office building parking ratio.

    1:125 sqm. Of gross floor area

  • 2

    Minimum width of a passageway connecting a street and a court.

    1.2m

  • 3

    Standard turn circle of a wheelchair

    1.50 m

  • 4

    Standard size of a perpendicular parking sl

    2.40 m x 5.00 m

  • 5

    Minimum number of wheelchair seating space for 51-300 seating capacity for auditoriums.

    4

  • 6

    Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose.

    6m

  • 7

    Minimum open space requirement for a corner lot.

    10% of lot area

  • 8

    Open space requirement for an interior lot.

    50% of lot area

  • 9

    Maximum projection beyond the property line of a footing along the national road and at least 2.40 m in depth.

    300 mm

  • 10

    Vacant space left between the building and lot lines less than 2.00 mts in width.

    Setback

  • 11

    Maximum rise of one row of seat to the next.

    0.40m

  • 12

    Tourist Bus Parking

    2 bus slots per hotel or theater

  • 13

    Markets

    1 parking slot per 150sqm shopping floor area

  • 14

    No cemetery shall be at ____ m radius from any water source

    50

  • 15

    Have central refuges of at least __m in depth and preferably 2 m, provided as a midcrossing shelter, where the width of carriageway to be crossed exceeds 10 m

    1.5

  • 16

    In cases where frameless transparent glass doors and any other vertical transparent glass panels are provided, such glass panels should be provided with horizontal or graphical patterns with contrasting gray value color against adjacent and background colors, between mm and ___m. above the floor to prevent PWDs from bumping against i

    800 and 1.50

  • 17

    Sidewalk/walkway headroom should not be less than___ m and preferably higher.

    2.00

  • Landscape Design and Technology

    Landscape Design and Technology

    Martha · 100問 · 2年前

    Landscape Design and Technology

    Landscape Design and Technology

    100問 • 2年前
    Martha

    HISTORY AND THEORY

    HISTORY AND THEORY

    Martha · 100問 · 2年前

    HISTORY AND THEORY

    HISTORY AND THEORY

    100問 • 2年前
    Martha

    PLANT DESIGN AND INTERIOR PLANTSCAPING

    PLANT DESIGN AND INTERIOR PLANTSCAPING

    Martha · 100問 · 2年前

    PLANT DESIGN AND INTERIOR PLANTSCAPING

    PLANT DESIGN AND INTERIOR PLANTSCAPING

    100問 • 2年前
    Martha

    Ecology

    Ecology

    Martha · 100問 · 2年前

    Ecology

    Ecology

    100問 • 2年前
    Martha

    Professional Practice and Ethics

    Professional Practice and Ethics

    Martha · 29問 · 2年前

    Professional Practice and Ethics

    Professional Practice and Ethics

    29問 • 2年前
    Martha

    HISTORY 2

    HISTORY 2

    Martha · 86問 · 2年前

    HISTORY 2

    HISTORY 2

    86問 • 2年前
    Martha

    Ecology 2

    Ecology 2

    Martha · 29問 · 1年前

    Ecology 2

    Ecology 2

    29問 • 1年前
    Martha

    Code of Ethics

    Code of Ethics

    Martha · 26問 · 1年前

    Code of Ethics

    Code of Ethics

    26問 • 1年前
    Martha

    Landscape Materials

    Landscape Materials

    Martha · 32問 · 1年前

    Landscape Materials

    Landscape Materials

    32問 • 1年前
    Martha

    National History of LA

    National History of LA

    Martha · 53問 · 1年前

    National History of LA

    National History of LA

    53問 • 1年前
    Martha

    Phil Standards

    Phil Standards

    Martha · 11問 · 1年前

    Phil Standards

    Phil Standards

    11問 • 1年前
    Martha

    Methods of Construction

    Methods of Construction

    Martha · 13問 · 1年前

    Methods of Construction

    Methods of Construction

    13問 • 1年前
    Martha

    STEINER COMPRESSED

    STEINER COMPRESSED

    Martha · 28問 · 1年前

    STEINER COMPRESSED

    STEINER COMPRESSED

    28問 • 1年前
    Martha

    PLANT FAMILIES

    PLANT FAMILIES

    Martha · 80問 · 1年前

    PLANT FAMILIES

    PLANT FAMILIES

    80問 • 1年前
    Martha

    Collated

    Collated

    Martha · 50問 · 1年前

    Collated

    Collated

    50問 • 1年前
    Martha

    International Works

    International Works

    Martha · 27問 · 1年前

    International Works

    International Works

    27問 • 1年前
    Martha

    問題一覧

  • 1

    Office building parking ratio.

    1:125 sqm. Of gross floor area

  • 2

    Minimum width of a passageway connecting a street and a court.

    1.2m

  • 3

    Standard turn circle of a wheelchair

    1.50 m

  • 4

    Standard size of a perpendicular parking sl

    2.40 m x 5.00 m

  • 5

    Minimum number of wheelchair seating space for 51-300 seating capacity for auditoriums.

    4

  • 6

    Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose.

    6m

  • 7

    Minimum open space requirement for a corner lot.

    10% of lot area

  • 8

    Open space requirement for an interior lot.

    50% of lot area

  • 9

    Maximum projection beyond the property line of a footing along the national road and at least 2.40 m in depth.

    300 mm

  • 10

    Vacant space left between the building and lot lines less than 2.00 mts in width.

    Setback

  • 11

    Maximum rise of one row of seat to the next.

    0.40m

  • 12

    Tourist Bus Parking

    2 bus slots per hotel or theater

  • 13

    Markets

    1 parking slot per 150sqm shopping floor area

  • 14

    No cemetery shall be at ____ m radius from any water source

    50

  • 15

    Have central refuges of at least __m in depth and preferably 2 m, provided as a midcrossing shelter, where the width of carriageway to be crossed exceeds 10 m

    1.5

  • 16

    In cases where frameless transparent glass doors and any other vertical transparent glass panels are provided, such glass panels should be provided with horizontal or graphical patterns with contrasting gray value color against adjacent and background colors, between mm and ___m. above the floor to prevent PWDs from bumping against i

    800 and 1.50

  • 17

    Sidewalk/walkway headroom should not be less than___ m and preferably higher.

    2.00