暗記メーカー

お問い合わせ
ログイン
Plumb. Code -1
  • Ian Calasang

  • 問題数 50 • 12/7/2023

    問題一覧

  • 1

    Who is the current chairman of the Board of Examiners for Master Plumber?

    Reynald B. Ilagan

  • 2

    The extension of a soil or waste stack above the highest horizontal drain connected to the stack.

    Stack Vent

  • 3

    What section of RA 1378 requires the creation of a Board of Examiners for Master Plumbers after 30 days of the approval of the said Act?

    Section 3

  • 4

    water-sealed trap

    water-sealed trap

  • 5

    Tunnels shall have a clear height of ___ above the pipe.

    0.6 m

  • 6

    According to the building code, the allowed material for the dry standpipe are _____.

    wrought iron and galvanized iron

  • 7

    A pipe flange that is not drilled for bolt holes.

    blank flange

  • 8

    Date of the Accreditation of NAMPAP

    October 2, 1975

  • 9

    Which of the following fixture group qualifies the definition of battery of fixtures?

    5 water closets

  • 10

    Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.

    Bitumen

  • 11

    A physical separation, which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected

    Air Break

  • 12

    This examination subject in Master Plumbing was originally split into two.

    Practical Problems

  • 13

    A water heater is classified as?

    Plumbing Appliance

  • 14

    Copper's outside diameter is always ____ larger than the standard size.

    1/8"

  • 15

    The First Amendment to the National Plumbing Code

    November 28, 1967

  • 16

    Wiped lead joints shall have an exposed surface on each side of a joint not less than _____.

    19 mm

  • 17

    Minimum weight of a lead for flashing or vent terminals

    14.63 kg per sqm

  • 18

    How much is an installation fee of a plumbing unit?

    24 pesos

  • 19

    How much is an installation fee for water closet, lavatory, sink, bathtub, grease and garage trap.

    7 pesos

  • 20

    NFPA __ is inspection, testing, and maintenance of water-based fire protection systems

    NFPA 25

  • 21

    Clean Water Act

    RA 9275

  • 22

    The Administrative Authority must be notified at least ___ working days before such inspection is intended.

    3

  • 23

    A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.

    Wye

  • 24

    In a plumbing unit, how many floor drains are included?

    3

  • 25

    1 fixture unit is equal to?

    1 cu.ft per minute

  • 26

    Copper tube for water supply piping shall have a weight of not less than _____.

    Type L

  • 27

    Maximum distance for the supports of vertical CISP

    every storey

  • 28

    Each member of the board, shall at the time of his appointment be at least _____ of age.

    30

  • 29

    All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application.

    6

  • 30

    8 psi is equal to _____.

    5.63 meters

  • 31

    A registered master plumber must not supplant another Registered Master Plumber after definite steps have already been taken toward his/her being commissioned to perform the contract

    Code of Ethics no. 2

  • 32

    A large opening in a sewer line or part of a plumbing system constructed with sufficient size for a man to gain access therein for maintenance purposes

    Manhole

  • 33

    The maximum interval of supports for a 25 mm and larger horizontal screwed pipe.

    3.6 m

  • 34

    The pressure existing without any flow motion

    Static Pressure

  • 35

    When was the National Plumbing Code promulgated and approved by the Malacañang?

    January 28, 1959

  • 36

    An open return bend usually made up of two 90° bends

    Return bend

  • 37

    What is the accreditation number of NAMPAP

    14

  • 38

    ASTM means?

    American Society for Testing and Materials

  • 39

    A valve opened and closed by the fall and rise, respectively, of an attached ball floating on the surface of the liquid.

    Ball Cock

  • 40

    Who shall administer the provisions of RA 1378?

    Board of Examiners for Master Plumbers

  • 41

    A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____.

    120 days

  • 42

    ECC means?

    Environmental Compliance Certificate

  • 43

    An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread.

    Slip Joint

  • 44

    The required thickness of lead bends and lead traps.

    3.2 mm

  • 45

    The top edge of a receptacle from where water overflows.

    Flood Level Rim

  • 46

    How many maximum fixtures can be served by a grease trap?

    4

  • 47

    What principle number: No water closet shall be located in a room or compartment which is not properly lighted and ventilated.

    Principle No. 16

  • 48

    A device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures

    Flush Valve

  • 49

    The year when NAMPAP was organized and registered with the Securities and Exchange Commission

    1935

  • 50

    The highest portion of the interior part of any pipe or conduit that is not vertical

    Obvert