問題一覧
1
Who is the current chairman of the Board of Examiners for Master Plumber?
Reynald B. Ilagan
2
The extension of a soil or waste stack above the highest horizontal drain connected to the stack.
Stack Vent
3
What section of RA 1378 requires the creation of a Board of Examiners for Master Plumbers after 30 days of the approval of the said Act?
Section 3
4
water-sealed trap
water-sealed trap
5
Tunnels shall have a clear height of ___ above the pipe.
0.6 m
6
According to the building code, the allowed material for the dry standpipe are _____.
wrought iron and galvanized iron
7
A pipe flange that is not drilled for bolt holes.
blank flange
8
Date of the Accreditation of NAMPAP
October 2, 1975
9
Which of the following fixture group qualifies the definition of battery of fixtures?
5 water closets
10
Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.
Bitumen
11
A physical separation, which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected
Air Break
12
This examination subject in Master Plumbing was originally split into two.
Practical Problems
13
A water heater is classified as?
Plumbing Appliance
14
Copper's outside diameter is always ____ larger than the standard size.
1/8"
15
The First Amendment to the National Plumbing Code
November 28, 1967
16
Wiped lead joints shall have an exposed surface on each side of a joint not less than _____.
19 mm
17
Minimum weight of a lead for flashing or vent terminals
14.63 kg per sqm
18
How much is an installation fee of a plumbing unit?
24 pesos
19
How much is an installation fee for water closet, lavatory, sink, bathtub, grease and garage trap.
7 pesos
20
NFPA __ is inspection, testing, and maintenance of water-based fire protection systems
NFPA 25
21
Clean Water Act
RA 9275
22
The Administrative Authority must be notified at least ___ working days before such inspection is intended.
3
23
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line.
Wye
24
In a plumbing unit, how many floor drains are included?
3
25
1 fixture unit is equal to?
1 cu.ft per minute
26
Copper tube for water supply piping shall have a weight of not less than _____.
Type L
27
Maximum distance for the supports of vertical CISP
every storey
28
Each member of the board, shall at the time of his appointment be at least _____ of age.
30
29
All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application.
6
30
8 psi is equal to _____.
5.63 meters
31
A registered master plumber must not supplant another Registered Master Plumber after definite steps have already been taken toward his/her being commissioned to perform the contract
Code of Ethics no. 2
32
A large opening in a sewer line or part of a plumbing system constructed with sufficient size for a man to gain access therein for maintenance purposes
Manhole
33
The maximum interval of supports for a 25 mm and larger horizontal screwed pipe.
3.6 m
34
The pressure existing without any flow motion
Static Pressure
35
When was the National Plumbing Code promulgated and approved by the Malacañang?
January 28, 1959
36
An open return bend usually made up of two 90° bends
Return bend
37
What is the accreditation number of NAMPAP
14
38
ASTM means?
American Society for Testing and Materials
39
A valve opened and closed by the fall and rise, respectively, of an attached ball floating on the surface of the liquid.
Ball Cock
40
Who shall administer the provisions of RA 1378?
Board of Examiners for Master Plumbers
41
A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____.
120 days
42
ECC means?
Environmental Compliance Certificate
43
An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread.
Slip Joint
44
The required thickness of lead bends and lead traps.
3.2 mm
45
The top edge of a receptacle from where water overflows.
Flood Level Rim
46
How many maximum fixtures can be served by a grease trap?
4
47
What principle number: No water closet shall be located in a room or compartment which is not properly lighted and ventilated.
Principle No. 16
48
A device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures
Flush Valve
49
The year when NAMPAP was organized and registered with the Securities and Exchange Commission
1935
50
The highest portion of the interior part of any pipe or conduit that is not vertical
Obvert