Plumb. Code - 2
  • Ian Calasang

  • 問題数 50 • 12/7/2023

    問題一覧

  • 1

    A pressure regulator must be installed if the local water service pressure is above ____

    80 ps

  • 2

    AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the _____ with the critical level not less than _____ above flood level rim.

    last valve; 152 mm

  • 3

    1 Kcal is how many BTU?

    3.965

  • 4

    Building Sewer or other drainage pipings must be installed not less than _____ within any building or structure.

    0.6 m

  • 5

    Water Closet provision for 300 females in Assembly Places for Public Use

    11

  • 6

    When a Public or Private Sewer is not available for use, excreta drainage piping from buildings and premises shall be connected to an approved _____.

    Private Sewage Disposal System

  • 7

    A standpipe having a remote control device at each hose station.

    Manually-Operated Standpipe System

  • 8

    Every building where _____ shall have a sewer service connection to a public or private sewer systems.

    plumbing fixtures are installed

  • 9

    A device installed in a drainage system to prevent reverse flow.

    Backwater Valve

  • 10

    Each tailpiece, continuous waste or waste and overflow shall not be less than ___ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures

    38 mm. O.D.

  • 11

    Potable water shall use solders and fluxes with a lead content not exceeding _____.

    0.2%

  • 12

    The public sewer may be considered not being available when a sewer is located more than _____ from any proposed building or exterior drainage facility.

    61 m

  • 13

    Hanger rod size for 5" pipe size

    13 mm

  • 14

    ode on Sanitation of the Philippines

    PD 856

  • 15

    A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____.

    Bathtub

  • 16

    Thickness of Continuous waste and fixture tailpiece- seamless drawn brass

    Gauge 20 (0.8 mm)

  • 17

    Trap arm size of Laundry Tub

    38 mm

  • 18

    Color of Steam Division- High Pressure Pipe

    White

  • 19

    Medical gas piping is most often joined by _____.

    Silver Brazing

  • 20

    How many fixture units if equivalent to a 30 gpm-rated sump?

    60 FU

  • 21

    (ANSI) Pipe Color code for Fire Quenching

    Red with White Lettering

  • 22

    Which of the following can be drained through an air break?

    evaporative cooler

  • 23

    Threads per inch for pipe size of 13 mm diameter.

    14

  • 24

    Galvanized wrought iron or galvanized steel pipe shall be kept _____.

    150 mm above ground

  • 25

    Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than _____.

    1033 kpa

  • 26

    A double check valve backflow preventer requires _____ minimum clearance at the bottom for maintenance.

    305 mm

  • 27

    What is the maximum Fixture unit loading of a 2" trap?

    4

  • 28

    Consists of a body, a checking member, and an atmospheric opening.

    Atmospheric Vacuum Breaker

  • 29

    Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _____ of mercury.

    0 to 63.5 cm

  • 30

    Limit stops shall be adjusted to deliver hot water with a maximum temperature of _____.

    120 °F

  • 31

    1 Water Closet and 1 Urinal must be provided for temporary workingmen facilities for each ____ workmen.

    30

  • 32

    What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?

    Decrease in DFU loading

  • 33

    An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.

    135°

  • 34

    A _____ diameter circular basin shall be equivalent to 1 lavatory.

    457.2 mm

  • 35

    Clotheswashers in groups of 3 or more shall be rated at _____ each for the common horiontal and vertical waste pipe sizing.

    6 FU

  • 36

    Trap arm size of a service sink

    51 mm

  • 37

    What is the maximum fixture loading of a 8" pipe sloped at 1%?

    2112

  • 38

    What is the allowed depth of shower dam or threshold?

    2"-9"

  • 39

    WSFU of a private hose bibb

    3

  • 40

    What is the Maximum DFU loading of a 102 mm branch?

    216

  • 41

    Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.

    bitumastic coating

  • 42

    Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least _____ larger than the _____ inlet.

    2 pipe sizes; largest side inlet

  • 43

    1 Laundry Tray must be provided per ____ persons.

    50

  • 44

    Minimum pipe sizing for a branch serving a 400 DFU

    127 mm

  • 45

    Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.

    Bitumen

  • 46

    Backflow prevention device for a hose bibb

    Atmospheric Vacuum Breaker

  • 47

    The transference of heat by the upward movement of a warm light air current.

    Convection

  • 48

    Preferred pipe for transporting gas

    Black Steel Pipe

  • 49

    Threads per inch of a 64 mm cleanout size

    8

  • 50

    Linings for showers shall not be nailed or perforated at any point less than _____ above the finished dam or threshold.

    1"