    This new concept in plumbing has almost completely eliminated the vent stack and other forms of ventilation, but still attained the desired functions and effectiveness.

    Sovent System

  • 2

    Minimum diameter of combination standpipe

    150 mm

  • 3

    The minimum size of a fire hose outlet of an interior wet standpipe.

    1 1/2"

  • 4

    A water closet, lavatory, and shower located together on the same room

    three-quarter bath

  • 5

    Chemical Symbol of Tin

    Sn

  • 6

    If the bell has hammer, the buzzer has _____.

    metal strip

  • 7

    The design, construction, and operation of the deepwells for the abstraction of groundwater shall be subject to the provisions of _____.

    Water Code of the Philippines

  • 8

    A fitting that connects a number of branches to main; it serves as a distribution point.

    Manifold

  • 9

    An approved pressure reduction device shall be permanently installed where static pressure of a wet standpipe exceeds _____.

    6.9 bar

  • 10

    Combination of hydrogen and carbon; a principal component of natural gas

    Methane

  • 11

    All fire service connections shall be located on a street front not less than ______.

    46 cm

  • 12

    The pipe connection in which a ball is held in a cup-like that allows movement in every direction.

    Ball Joint

  • 13

    Maximum height of signages according to BP 344

    1.60 m

  • 14

    The part of the valve housing through which the stem extends.

    Bonnet

  • 15

    Diameter of Class I System hose

    64 mm

  • 16

    When installing _____, the authority having jurisdiction shall require evidence of the competency of the installers.

    medical gas piping

  • 17

    Vents suitable for listed draft-hood equipped, gas-fired appliances, including most domestic heating and hot water systems

    Type B vents

  • 18

    What Fire Extinguisher is least compatible for Class B Fires?

    Wet Chemical

  • 19

    Maximum height of urinal lip

    0.48 m

  • 20

    A pipe installed in buildings not as part of the water supply or disposal system, but primarily for use as water conveyance in case of fire

    Standpipe

  • 21

    How do you connect PPR?

    Fusion Welding

  • 22

    Fire extinguisher used for Class D fires

    Dry Powder Extinguisher

  • 23

    A full-way valve used to regulate a fluid flow in which a threaded stem raises & lowers a wedge-shaped disk

    Gate Valve

  • 24

    The minimum diameter of a dry standpipe requiring a 3-way siamese connection

    125 mm

  • 25

    A Positive Displacement Pump wherein the high-pressure seal reciprocates with the piston

    Piston Pump

  • 26

    Maximum height of water closet according to BP 344

    0.45 m

  • 27

    It injects large quantities of fresh air into this compartment to mix the compartment’s entire contents and to provide oxygen for the aerobic digester process.

    Aerator

  • 28

    Standard for the Fire Protection of Telecommunications Facilities

    NFPA 76

  • 29

    Fire service connection in street front for Dry Standpipe shall be _____.

    46 to 122 cm

  • 30

    The sum of static head and velocity head at a pump discharge

    Total Discharge Head

  • 31

    Standard for Installation of Sprinkler Systems

    NFPA 13

  • 32

    Consists of bacteria, algae, fungi, silt, protoza, and other colloidal matters making the water colored and acidic

    Suspended and Colloidal materials

  • 33

    The device that operates automatically when refilling the water tank after each discharge and shutting off completely when the tank is already full.

    Float Valve

  • 34

    Diameter of dry standpipe if the highest outlet is 23 m or less

    102 mm

  • 35

    Minimum dimension of accessible water closets

    1.7 m x 1.8 m

  • 36

    Pipe material used for LPG

    PE

  • 37

    A small pump connected to a fire sprinkler system to maintain pressure in the sprinkler pipes

    Jockey Pump

  • 38

    All dry standpipes shall be equipped with a two-way 63 mm outlet above the roof. All outlets shall be equipped with _____.

    gate valves

  • 39

    All interior wet standpipes shall be connected to a street main not less than ___ in diameter.

    4"

  • 40

    An alarming device that produces a buzzing sound which is caused by the rapid vibration of armature.

    Buzzer

  • 41

    A pump has a 900 revolutions per minute. After the maintenance, the rate of revolution increased to 950. Calculate the new head pressure if the original head pressure is 100 ft.

    112 ft

  • 42

    It spatters or scatters the effluent in drops or small blobs wherein they are mixed with the air

    Aerator

  • 43

    A type of Globe valve which has a wide bearing surface producing good resistance to the cutting effects of scale, dirt, and other kinds of foreign matter found inside the pipe

    Plug Type

  • 44

    Which of the following is not a quarter-turn valve?

    Neddle Valves

  • 45

    Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe

    ASTM D1785

  • 46

    A Flow Meter that measures an induced voltage generated by the fluid as it flows through a pipe.

    Electromagnetic Flow Meter

  • 47

    A nipple installed where fittings or valves are to be very close to each other

    Close Nipple

  • Littons part 2-0314

    Littons part 2-0314

    Ian Calasang · 60問 · 2年前

    Littons part 2-0314

    Littons part 2-0314

    60問 • 2年前
    Ian Calasang

    PSAD TERMS 2011-2018

    PSAD TERMS 2011-2018

    Ian Calasang · 3回閲覧 · 60問 · 2年前

    PSAD TERMS 2011-2018

    PSAD TERMS 2011-2018

    3回閲覧 • 60問 • 2年前
    Ian Calasang

    Littons

    Littons

    Ian Calasang · 4回閲覧 · 61問 · 2年前

    Littons

    Littons

    4回閲覧 • 61問 • 2年前
    Ian Calasang

    Probability

    Probability

    Ian Calasang · 61問 · 3年前

    Probability

    Probability

    61問 • 3年前
    Ian Calasang

    DPWH II

    DPWH II

    Ian Calasang · 43問 · 3年前

    DPWH II

    DPWH II

    43問 • 3年前
    Ian Calasang

    MSTHC Terms

    MSTHC Terms

    Ian Calasang · 53問 · 3年前

    MSTHC Terms

    MSTHC Terms

    53問 • 3年前
    Ian Calasang

    PSAD TERMS 2011-2018

    PSAD TERMS 2011-2018

    Ian Calasang · 54問 · 2年前

    PSAD TERMS 2011-2018

    PSAD TERMS 2011-2018

    54問 • 2年前
    Ian Calasang

    LOOKSFAM MODULES GILLE updated[josh t.]

    LOOKSFAM MODULES GILLE updated[josh t.]

    Ian Calasang · 37問 · 3年前

    LOOKSFAM MODULES GILLE updated[josh t.]

    LOOKSFAM MODULES GILLE updated[josh t.]

    37問 • 3年前
    Ian Calasang

    HGE TERMS CE REF 4

    HGE TERMS CE REF 4

    Ian Calasang · 36問 · 2年前

    HGE TERMS CE REF 4

    HGE TERMS CE REF 4

    36問 • 2年前
    Ian Calasang

    Engineering Economics

    Engineering Economics

    Ian Calasang · 94問 · 3年前

    Engineering Economics

    Engineering Economics

    94問 • 3年前
    Ian Calasang

    dpwh

    dpwh

    Ian Calasang · 34問 · 3年前

    dpwh

    dpwh

    34問 • 3年前
    Ian Calasang

    Terms-1

    Terms-1

    Ian Calasang · 89問 · 2年前

    Terms-1

    Terms-1

    89問 • 2年前
    Ian Calasang

    Terms-2

    Terms-2

    Ian Calasang · 89問 · 2年前

    Terms-2

    Terms-2

    89問 • 2年前
    Ian Calasang

    Terms-3

    Terms-3

    Ian Calasang · 90問 · 2年前

    Terms-3

    Terms-3

    90問 • 2年前
    Ian Calasang

    Plumb. Code -1

    Plumb. Code -1

    Ian Calasang · 50問 · 2年前

    Plumb. Code -1

    Plumb. Code -1

    50問 • 2年前
    Ian Calasang

    Plumb. Code - 2

    Plumb. Code - 2

    Ian Calasang · 50問 · 2年前

    Plumb. Code - 2

    Plumb. Code - 2

    50問 • 2年前
    Ian Calasang

    Plumb. Code -3

    Plumb. Code -3

    Ian Calasang · 50問 · 2年前

    Plumb. Code -3

    Plumb. Code -3

    50問 • 2年前
    Ian Calasang

    SPDI-1

    SPDI-1

    Ian Calasang · 50問 · 2年前

    SPDI-1

    SPDI-1

    50問 • 2年前
    Ian Calasang

    everything numbers! Test 5

    everything numbers! Test 5

    Ian Calasang · 80問 · 2年前

    everything numbers! Test 5

    everything numbers! Test 5

    80問 • 2年前
    Ian Calasang

    Codes/Laws -7

    Codes/Laws -7

    Ian Calasang · 60問 · 2年前

    Codes/Laws -7

    Codes/Laws -7

    60問 • 2年前
    Ian Calasang

    midterm fle

    midterm fle

    Ian Calasang · 6問 · 1年前

    midterm fle

    midterm fle

    6問 • 1年前
    Ian Calasang

    問題一覧

  • 1

    This new concept in plumbing has almost completely eliminated the vent stack and other forms of ventilation, but still attained the desired functions and effectiveness.

    Sovent System

  • 2

    Minimum diameter of combination standpipe

    150 mm

  • 3

    The minimum size of a fire hose outlet of an interior wet standpipe.

    1 1/2"

  • 4

    A water closet, lavatory, and shower located together on the same room

    three-quarter bath

  • 5

    Chemical Symbol of Tin

    Sn

  • 6

    If the bell has hammer, the buzzer has _____.

    metal strip

  • 7

    The design, construction, and operation of the deepwells for the abstraction of groundwater shall be subject to the provisions of _____.

    Water Code of the Philippines

  • 8

    A fitting that connects a number of branches to main; it serves as a distribution point.

    Manifold

  • 9

    An approved pressure reduction device shall be permanently installed where static pressure of a wet standpipe exceeds _____.

    6.9 bar

  • 10

    Combination of hydrogen and carbon; a principal component of natural gas

    Methane

  • 11

    All fire service connections shall be located on a street front not less than ______.

    46 cm

  • 12

    The pipe connection in which a ball is held in a cup-like that allows movement in every direction.

    Ball Joint

  • 13

    Maximum height of signages according to BP 344

    1.60 m

  • 14

    The part of the valve housing through which the stem extends.

    Bonnet

  • 15

    Diameter of Class I System hose

    64 mm

  • 16

    When installing _____, the authority having jurisdiction shall require evidence of the competency of the installers.

    medical gas piping

  • 17

    Vents suitable for listed draft-hood equipped, gas-fired appliances, including most domestic heating and hot water systems

    Type B vents

  • 18

    What Fire Extinguisher is least compatible for Class B Fires?

    Wet Chemical

  • 19

    Maximum height of urinal lip

    0.48 m

  • 20

    A pipe installed in buildings not as part of the water supply or disposal system, but primarily for use as water conveyance in case of fire

    Standpipe

  • 21

    How do you connect PPR?

    Fusion Welding

  • 22

    Fire extinguisher used for Class D fires

    Dry Powder Extinguisher

  • 23

    A full-way valve used to regulate a fluid flow in which a threaded stem raises & lowers a wedge-shaped disk

    Gate Valve

  • 24

    The minimum diameter of a dry standpipe requiring a 3-way siamese connection

    125 mm

  • 25

    A Positive Displacement Pump wherein the high-pressure seal reciprocates with the piston

    Piston Pump

  • 26

    Maximum height of water closet according to BP 344

    0.45 m

  • 27

    It injects large quantities of fresh air into this compartment to mix the compartment’s entire contents and to provide oxygen for the aerobic digester process.

    Aerator

  • 28

    Standard for the Fire Protection of Telecommunications Facilities

    NFPA 76

  • 29

    Fire service connection in street front for Dry Standpipe shall be _____.

    46 to 122 cm

  • 30

    The sum of static head and velocity head at a pump discharge

    Total Discharge Head

  • 31

    Standard for Installation of Sprinkler Systems

    NFPA 13

  • 32

    Consists of bacteria, algae, fungi, silt, protoza, and other colloidal matters making the water colored and acidic

    Suspended and Colloidal materials

  • 33

    The device that operates automatically when refilling the water tank after each discharge and shutting off completely when the tank is already full.

    Float Valve

  • 34

    Diameter of dry standpipe if the highest outlet is 23 m or less

    102 mm

  • 35

    Minimum dimension of accessible water closets

    1.7 m x 1.8 m

  • 36

    Pipe material used for LPG

    PE

  • 37

    A small pump connected to a fire sprinkler system to maintain pressure in the sprinkler pipes

    Jockey Pump

  • 38

    All dry standpipes shall be equipped with a two-way 63 mm outlet above the roof. All outlets shall be equipped with _____.

    gate valves

  • 39

    All interior wet standpipes shall be connected to a street main not less than ___ in diameter.

    4"

  • 40

    An alarming device that produces a buzzing sound which is caused by the rapid vibration of armature.

    Buzzer

  • 41

    A pump has a 900 revolutions per minute. After the maintenance, the rate of revolution increased to 950. Calculate the new head pressure if the original head pressure is 100 ft.

    112 ft

  • 42

    It spatters or scatters the effluent in drops or small blobs wherein they are mixed with the air

    Aerator

  • 43

    A type of Globe valve which has a wide bearing surface producing good resistance to the cutting effects of scale, dirt, and other kinds of foreign matter found inside the pipe

    Plug Type

  • 44

    Which of the following is not a quarter-turn valve?

    Neddle Valves

  • 45

    Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe

    ASTM D1785

  • 46

    A Flow Meter that measures an induced voltage generated by the fluid as it flows through a pipe.

    Electromagnetic Flow Meter

  • 47

    A nipple installed where fittings or valves are to be very close to each other

    Close Nipple