1
RA 7920
Electrical Engg. Law
2
RA 8495
Mech. Engg. Law
3
True or false: No service drop conductors or any other wiring shall pass over swimming pools
True
4
Clearance of service drops from highest point of roofs
2.50m
5
Clearance of service drops from the ground
3.00m
6
Clearance of service drops (horizontal) from windows/porches
1.00m
7
Clearance of service drops from the crown of the street or sidewalk
5.50m
8
minimum hoistway pit or an elevator from underside of car to bottom of pit
600mm
9
Maximum number of elevators in a single hoistway
4
10
True or False Only residential buildings 5 storeys or higher are allowed to have an elevator
False
11
Maximum inclination of an escalator from horizontal
30 Degrees
12
Maximum Width of step of an escalator
330 mm
13
Minimum width between ballustrades
560 mm
14
Maximum width between ballustrades
1200 mm
15
Maximum speed of an escalator
38 m per minute
16
AC comfortable cooling standards for temperature
20 Degrees - 24 Degrees Celsius
17
AC comfortable cooling standards for Humidity
50% - 60%
18
AC comfortable cooling standards for air movement
4.60 - 7.60 meters per minute
19
True or False Installation of pumping equipment directly from the public water supply system is prohibited
True
20
True or False Installation of pumping equipment directly from the public water supply system is allowed
False
21
You need to provide fire extinguishing systems when unexposed films in shipping containers exceed 14.00cubic meters
True
22
You need to provide fire extinguishing systems when unexposed films in shipping containers exceed 12.00cubic meters
False
23
You need to provide fire extinguishing systems when shelving used for storing film exceeds 1.40 cubic meters in capacity
True
24
You need to provide fire extinguishing systems when shelving used for storing film exceeds 1.00 cubic meters in capacity
False
25
No films shall be stored within 600mm of steam pipes, chimneys, or other sources of heat
True
26
No films shall be stored within 500mm of steam pipes, chimneys, or other sources of heat
False
27
A structural unit, the integral parts of which have been built-up or assembled prior to incorporation in the building
Prefabricated assembly
28
To determine structural adequacy, they shall pass special tests conducted by accredited material testing laboratories
True
29
Those which have a flame-spread rating of 225 or less are approved plastics
True
30
Those which have a flame-spread rating of 335 or less are approved plastics
False
31
Those with a smoke density not greater than that obtained from the burning of untreated wood are approved plastics
True
32
Those with a smoke density greater than that obtained from the burning of untreated wood are approved plastics
False
33
Those whose products of combustion are no more toxic than those of untreated wood Plastic doors are approved plastics
True
34
Plastic doors are allowed except for entrance doors and exit doors, which should be of materials other than plastics
True
35
Plastic doors are allowed except for Restrooms and Powder Rooms, which should be of materials other than plastics
False
36
Paint spray booths shall be constructed of not less than _____ US Gauge in thickness
No. 18
37
Maximum area of a spray paint booth
150 sqm
38
The floor of the booth, if combustible, shall be covered with non-combustible material
True
39
Each glass panel shall bear the manufacturer’s label designating the type and thickness of glass
True
40
No sign shall be erected in such a manner as to confuse or obstruct the view or interpretation of any official traffic sign/device
True
41
Signs shall be erected in such a manner as to confuse or obstruct the view or interpretation of any official traffic sign/device
False
42
Signs in any foreign language shall have a translation in English or the local dialect
True
43
No sign shall be erected in such a manner as to confuse or obstruct the view or interpretation of any official traffic sign/device
True
44
No signs shall be installed on rooftops of buildings of wooden structures or of buildings with wooden roof framing
True
45
You need to provide grounding of metallic parts of roof signs exposed to lightning
True
46
Shall be located within the property line and under no circumstances shall they occupy the RROW
Ground Signs
47
Maximum projection of signs on a non-arcaded RROW
1.20 m
48
Maximum projection of signs on an arcaded RROW
0.60 m
49
Maximum projection of signs on buildings abutting RROW without sidewalks
0.30 m
50
Minimum vertical clearance of a Non-arcaded RROW from road surface to lowest part of signs
3.00 m
51
Minimum vertical clearance on an Arcaded RROW from road surface to lowest part of signs
5.00m