暗記メーカー
ログイン
NBC 13-20
  • DHANE JOAN NICOLE QUIDLAT

  • 問題数 51 • 5/20/2024

    記憶度

    完璧

    7

    覚えた

    20

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    True or False Installation of pumping equipment directly from the public water supply system is prohibited

    True

  • 2

    Maximum speed of an escalator

    38 m per minute

  • 3

    Maximum width between ballustrades

    1200 mm

  • 4

    Maximum projection of signs on a non-arcaded RROW

    1.20 m

  • 5

    No sign shall be erected in such a manner as to confuse or obstruct the view or interpretation of any official traffic sign/device

    True

  • 6

    Paint spray booths shall be constructed of not less than _____ US Gauge in thickness

    No. 18

  • 7

    AC comfortable cooling standards for air movement

    4.60 - 7.60 meters per minute

  • 8

    The floor of the booth, if combustible, shall be covered with non-combustible material

    True

  • 9

    Those whose products of combustion are no more toxic than those of untreated wood Plastic doors are approved plastics

    True

  • 10

    Those which have a flame-spread rating of 225 or less are approved plastics

    True

  • 11

    Those which have a flame-spread rating of 335 or less are approved plastics

    False

  • 12

    To determine structural adequacy, they shall pass special tests conducted by accredited material testing laboratories

    True

  • 13

    Clearance of service drops from highest point of roofs

    2.50m

  • 14

    Each glass panel shall bear the manufacturer’s label designating the type and thickness of glass

    True

  • 15

    No sign shall be erected in such a manner as to confuse or obstruct the view or interpretation of any official traffic sign/device

    True

  • 16

    Clearance of service drops from the ground

    3.00m

  • 17

    Maximum projection of signs on an arcaded RROW

    0.60 m

  • 18

    A structural unit, the integral parts of which have been built-up or assembled prior to incorporation in the building

    Prefabricated assembly

  • 19

    Shall be located within the property line and under no circumstances shall they occupy the RROW

    Ground Signs

  • 20

    True or False Only residential buildings 5 storeys or higher are allowed to have an elevator

    False

  • 21

    True or False Installation of pumping equipment directly from the public water supply system is allowed

    False

  • 22

    Minimum width between ballustrades

    560 mm

  • 23

    No films shall be stored within 500mm of steam pipes, chimneys, or other sources of heat

    False

  • 24

    AC comfortable cooling standards for Humidity

    50% - 60%

  • 25

    Signs shall be erected in such a manner as to confuse or obstruct the view or interpretation of any official traffic sign/device

    False

  • 26

    Maximum number of elevators in a single hoistway

    4

  • 27

    Signs in any foreign language shall have a translation in English or the local dialect

    True

  • 28

    True or false: No service drop conductors or any other wiring shall pass over swimming pools

    True

  • 29

    Those with a smoke density greater than that obtained from the burning of untreated wood are approved plastics

    False

  • 30

    Maximum Width of step of an escalator

    330 mm

  • 31

    You need to provide fire extinguishing systems when unexposed films in shipping containers exceed 14.00cubic meters

    True

  • 32

    AC comfortable cooling standards for temperature

    20 Degrees - 24 Degrees Celsius

  • 33

    Minimum vertical clearance of a Non-arcaded RROW from road surface to lowest part of signs

    3.00 m

  • 34

    Minimum vertical clearance on an Arcaded RROW from road surface to lowest part of signs

    5.00m

  • 35

    No signs shall be installed on rooftops of buildings of wooden structures or of buildings with wooden roof framing

    True

  • 36

    Maximum inclination of an escalator from horizontal

    30 Degrees

  • 37

    Maximum area of a spray paint booth

    150 sqm

  • 38

    You need to provide fire extinguishing systems when unexposed films in shipping containers exceed 12.00cubic meters

    False

  • 39

    minimum hoistway pit or an elevator from underside of car to bottom of pit

    600mm

  • 40

    Plastic doors are allowed except for entrance doors and exit doors, which should be of materials other than plastics

    True

  • 41

    RA 8495

    Mech. Engg. Law

  • 42

    No films shall be stored within 600mm of steam pipes, chimneys, or other sources of heat

    True

  • 43

    You need to provide fire extinguishing systems when shelving used for storing film exceeds 1.40 cubic meters in capacity

    True

  • 44

    Clearance of service drops from the crown of the street or sidewalk

    5.50m

  • 45

    Those with a smoke density not greater than that obtained from the burning of untreated wood are approved plastics

    True

  • 46

    Plastic doors are allowed except for Restrooms and Powder Rooms, which should be of materials other than plastics

    False

  • 47

    RA 7920

    Electrical Engg. Law

  • 48

    You need to provide fire extinguishing systems when shelving used for storing film exceeds 1.00 cubic meters in capacity

    False

  • 49

    You need to provide grounding of metallic parts of roof signs exposed to lightning

    True

  • 50

    Maximum projection of signs on buildings abutting RROW without sidewalks

    0.30 m

  • 51

    Clearance of service drops (horizontal) from windows/porches

    1.00m