ログイン

PLUMBING CODE 1
17問 • 1年前
  • Mea Jane Ramos
  • 通報

    問題一覧

  • 1

    THE REVISED NATIONAL PLUMBING CODE OF THE PHILIPPINES CHAPTER 3: _______

    General Regulations

  • 2

    Drainage pipes shall be run in practical alignments & at a uniform slope between manholes of not less than _______ toward the point of disposal.

    2%

  • 3

    Any such pipe or piping 102mm or larger in diameter may have a slope of _______ provided it is approved by Administrative Authority.

    1%

  • 4

    102 mm and 152.4mm in diameter may have a slope of not less than _______.

    1%

  • 5

    203mm and larger in diameter may have a slope of not less than _______.

    0.5%

  • 6

    Changes in direction of piping shall be made using approved pipe fittings & shall be the angles presented by:

    22 ½ degrees bend, 45 degrees bend, 60 degrees bend

  • 7

    Horizontal drainage lines connecting to a vertical stack shall enter through:

    45 wye branches, combination wye and 1/8 bend branches, other approved fittings of longer sweeps

  • 8

    Horizontal drainage lines connecting to other horizontal drainage lines shall enter through:

    45 wye branches, combination wye and 1/8 bend branches, other approved fittings of longer sweeps

  • 9

    Vertical drainage lines connecting to other horizontal drainage line shall enter through:

    45 wye branches, other approved fittings of longer sweeps, 60 degree branches

  • 10

    No _______ or _______ piping shall be drilled & tapped for making connections thereto, and no cast iron soil pipe shall be threaded.

    Drainage, Vent

  • 11

    No _______ shall be made to a closet bend or stub of a water closet or similar fixtures.

    Waste Connection

  • 12

    No _______ pipe shall be used as a soil or waste pipe & vice versa.

    Vent

  • 13

    Bell & Spigot & Hubless pipe shall be supported at every storey or closer.

    Cast Iron Soil Pipe

  • 14

    Iron Pipe Size (IPS) shall be supported at not less than every other storey height.

    Screwed Pipe

  • 15

    Shall be supported at each storey or at a maximum intervals of 3m o.c.

    Copper Tubing

  • 16

    Shall be supported at intervals not exceeding 1.20m at centers with a rigid vertical back-up

    Lead Pipe

  • 17

    Shall be supported at every 1m interval.

    Plastic Pipe

  • HGE TERMS

    HGE TERMS

    Mea Jane Ramos · 73問 · 1年前

    HGE TERMS

    HGE TERMS

    73問 • 1年前
    Mea Jane Ramos

    MSTC TERMS

    MSTC TERMS

    Mea Jane Ramos · 62問 · 1年前

    MSTC TERMS

    MSTC TERMS

    62問 • 1年前
    Mea Jane Ramos

    Transportation Terms

    Transportation Terms

    Mea Jane Ramos · 77問 · 1年前

    Transportation Terms

    Transportation Terms

    77問 • 1年前
    Mea Jane Ramos

    TRANSPORTATION AND HIGHWAY TERMS

    TRANSPORTATION AND HIGHWAY TERMS

    Mea Jane Ramos · 100問 · 1年前

    TRANSPORTATION AND HIGHWAY TERMS

    TRANSPORTATION AND HIGHWAY TERMS

    100問 • 1年前
    Mea Jane Ramos

    TRANSPORTATION AND HIGHWAY TERMS 1

    TRANSPORTATION AND HIGHWAY TERMS 1

    Mea Jane Ramos · 39問 · 1年前

    TRANSPORTATION AND HIGHWAY TERMS 1

    TRANSPORTATION AND HIGHWAY TERMS 1

    39問 • 1年前
    Mea Jane Ramos

    Practical Questions for Transportation and Highway Engineering

    Practical Questions for Transportation and Highway Engineering

    Mea Jane Ramos · 84問 · 1年前

    Practical Questions for Transportation and Highway Engineering

    Practical Questions for Transportation and Highway Engineering

    84問 • 1年前
    Mea Jane Ramos

    HGE TERMS

    HGE TERMS

    Mea Jane Ramos · 73問 · 1年前

    HGE TERMS

    HGE TERMS

    73問 • 1年前
    Mea Jane Ramos

    ANALOGY

    ANALOGY

    Mea Jane Ramos · 35問 · 1年前

    ANALOGY

    ANALOGY

    35問 • 1年前
    Mea Jane Ramos

    HGE TERMS

    HGE TERMS

    Mea Jane Ramos · 73問 · 1年前

    HGE TERMS

    HGE TERMS

    73問 • 1年前
    Mea Jane Ramos

    PLUMBING TERMINOLOGIES 1

    PLUMBING TERMINOLOGIES 1

    Mea Jane Ramos · 100問 · 1年前

    PLUMBING TERMINOLOGIES 1

    PLUMBING TERMINOLOGIES 1

    100問 • 1年前
    Mea Jane Ramos

    PLUMBING TERMINOLOGIES 2

    PLUMBING TERMINOLOGIES 2

    Mea Jane Ramos · 100問 · 1年前

    PLUMBING TERMINOLOGIES 2

    PLUMBING TERMINOLOGIES 2

    100問 • 1年前
    Mea Jane Ramos

    PLUMBING TERMINOLOGIES 3

    PLUMBING TERMINOLOGIES 3

    Mea Jane Ramos · 20問 · 1年前

    PLUMBING TERMINOLOGIES 3

    PLUMBING TERMINOLOGIES 3

    20問 • 1年前
    Mea Jane Ramos

    PLUMBING CODE 2023

    PLUMBING CODE 2023

    Mea Jane Ramos · 99問 · 1年前

    PLUMBING CODE 2023

    PLUMBING CODE 2023

    99問 • 1年前
    Mea Jane Ramos

    PLUMBING ARITHMETIC 2023

    PLUMBING ARITHMETIC 2023

    Mea Jane Ramos · 100問 · 1年前

    PLUMBING ARITHMETIC 2023

    PLUMBING ARITHMETIC 2023

    100問 • 1年前
    Mea Jane Ramos

    PLUMBING CODE

    PLUMBING CODE

    Mea Jane Ramos · 59問 · 1年前

    PLUMBING CODE

    PLUMBING CODE

    59問 • 1年前
    Mea Jane Ramos

    PLUMBING CODE DEFINITION

    PLUMBING CODE DEFINITION

    Mea Jane Ramos · 71問 · 1年前

    PLUMBING CODE DEFINITION

    PLUMBING CODE DEFINITION

    71問 • 1年前
    Mea Jane Ramos

    問題一覧

  • 1

    THE REVISED NATIONAL PLUMBING CODE OF THE PHILIPPINES CHAPTER 3: _______

    General Regulations

  • 2

    Drainage pipes shall be run in practical alignments & at a uniform slope between manholes of not less than _______ toward the point of disposal.

    2%

  • 3

    Any such pipe or piping 102mm or larger in diameter may have a slope of _______ provided it is approved by Administrative Authority.

    1%

  • 4

    102 mm and 152.4mm in diameter may have a slope of not less than _______.

    1%

  • 5

    203mm and larger in diameter may have a slope of not less than _______.

    0.5%

  • 6

    Changes in direction of piping shall be made using approved pipe fittings & shall be the angles presented by:

    22 ½ degrees bend, 45 degrees bend, 60 degrees bend

  • 7

    Horizontal drainage lines connecting to a vertical stack shall enter through:

    45 wye branches, combination wye and 1/8 bend branches, other approved fittings of longer sweeps

  • 8

    Horizontal drainage lines connecting to other horizontal drainage lines shall enter through:

    45 wye branches, combination wye and 1/8 bend branches, other approved fittings of longer sweeps

  • 9

    Vertical drainage lines connecting to other horizontal drainage line shall enter through:

    45 wye branches, other approved fittings of longer sweeps, 60 degree branches

  • 10

    No _______ or _______ piping shall be drilled & tapped for making connections thereto, and no cast iron soil pipe shall be threaded.

    Drainage, Vent

  • 11

    No _______ shall be made to a closet bend or stub of a water closet or similar fixtures.

    Waste Connection

  • 12

    No _______ pipe shall be used as a soil or waste pipe & vice versa.

    Vent

  • 13

    Bell & Spigot & Hubless pipe shall be supported at every storey or closer.

    Cast Iron Soil Pipe

  • 14

    Iron Pipe Size (IPS) shall be supported at not less than every other storey height.

    Screwed Pipe

  • 15

    Shall be supported at each storey or at a maximum intervals of 3m o.c.

    Copper Tubing

  • 16

    Shall be supported at intervals not exceeding 1.20m at centers with a rigid vertical back-up

    Lead Pipe

  • 17

    Shall be supported at every 1m interval.

    Plastic Pipe