ログイン

DESIGN DAY 2

DESIGN DAY 2
97問 • 1年前
  • LazyXKing
  • 通報

    問題一覧

  • 1

    architects credo: "I shall endeavor to do my duty in the protection odf our common environment and the preservation of architectural heritage for the sake of the present and future generations"

    legacy

  • 2

    amihan

    northeast

  • 3

    habagat

    southwest

  • 4

    good general lighting color for work areas in the workshop

    daylight

  • 5

    flooring material that have lowest carbon footprint

    baguio stone

  • 6

    minimum knee clearance for a dining area

    55cm

  • 7

    what is the densification of a fill by mechanical means?

    compaction

  • 8

    as per pd1096, wht is the minimum width for access road to interior lots?

    3m

  • 9

    what shall be the minimum distance in meters bt the FFL and ceiling, as compliance under nbcp

    2.70

  • 10

    mechanical systems and/or equipment installations shall be subject to the requirements of the

    philippine mechanical engineering code

  • 11

    what is the highest elevation of the light industrial zone?

    2.9m

  • 12

    rule7&8 of nbcp, what is the meaning of UTS

    utilities transportation and services

  • 13

    which one is not considered part of the GFA?

    underground storage tanks

  • 14

    the size of an average automobile (car) parking slot must be computed at ___ for perpendicular or diagonal parking

    2.5m x 5.0m

  • 15

    what is the best way to provide for the convenience of both people in wheelchair and blind persons?

    railings

  • 16

    what type of perspective is to be employed on the presentation if you wish to show your client the full extent of the main facade?

    one-point perspective

  • 17

    great parking lots are safe, easy access for wheelchairs and maintaining good sight lines. what is the most commonly used and most economical parking layout of parking spaces?

    parallel parking

  • 18

    in waterproofing a balcony, up to where is the extent of the waterproofing installation?

    along the whole floor of the balcony up to the adjacent wall connected

  • 19

    which is considered as non-GFA?

    parking space

  • 20

    RA 9514, what is the meaning of the abbreviation FSEC?

    fire safety evaluation clearance

  • 21

    ceiling, what type of paint is to be applied?

    flat paint so that it wont be glaring

  • 22

    RA 9514, occupant load factor for less concentrated use such as conference rooms, dining rooms, gyms?

    1.4 sqm/person

  • 23

    RA 9514, occupant load factor for concentrated use without fixed seats, such as auditoriums, places of worship, dance floors?

    0.65 sqm/person

  • 24

    for the solar control devices along east and west, what will be the appropriate shading?

    vertical louvres

  • 25

    what is NOT beling among the choices

    condura

  • 26

    PD 1096, which of the following is NOT a basis for assessment of building permit fees?

    land value

  • 27

    rule8 of pd1096, in a high rise apartment or residential condominiums of more than 5 stories, atleast how many passenger elevator be kept on 24 hour constant service?

    1

  • 28

    as per pd1096, what is the minimum air space per person for a habitable room with natural ventilation?

    14cum

  • 29

    which of the following is the most economical architectural flooring material to use on the projects rentable units?

    vinyl strips

  • 30

    waterproofing is required on the roofdeck. what type would be employed?

    membrane type

  • 31

    under bp344, what is the maximum height of the tapping rail if in any case a blind uses the building (for him to be assisted)?

    0.35m

  • 32

    RA 9514, floor level changes shall not vary by more than?

    1.3cm

  • 33

    pd1096 nbcp, what is the portion of the building between floor and ceiling which is wholly or partly below grade and so located that the vertical distance from the grade to floor below is equal to or greater than the vertical distance feom grade to ceiling?

    cellar

  • 34

    what is the term for the required open space left between the outermost face of the building/structure and the property lines?

    yard

  • 35

    if you have to use vinyl for its flooring what brand would you use?

    kent

  • 36

    ratio of a concrete mix would you use for its beam slab?

    1:2:4

  • 37

    what will be the elevation of ground floor, if from parking to walkway has 2 entry steps?

    300mm

  • 38

    what is the common term for the main post at the foot of a stairway or stoop?

    newel

  • 39

    under bp344, what is the distance of the building main entrance to the elevator?

    30m

  • 40

    under bp344, what is the minimum size of an elevator car?

    1.10 x 1.40

  • 41

    what is the standard height of raking handrail?

    90cm-110cm

  • 42

    what is the standard height of window sill from the floor line?

    0.9m

  • 43

    which is not a requirement in applying for building permit?

    latest income tax

  • 44

    what is the recommended dining table length for 6-person seating?

    210cm

  • 45

    the bedroom would be painted with a color that has the tendency of mitigating agressive behavior. what is to be used?

    pink

  • 46

    a front yard may be partly paved/hardscape (converted into a courtyard) to serve as a carport but only for what zoning?

    all mentioned above

  • 47

    what line uses connecting points that have the same elevation?

    contour line

  • 48

    for a 3-fixture t&b, how many floor drain should be provided?

    2

  • 49

    which is not an interior appliance?

    exhaust fan

  • 50

    the placing of concrete using pneumatic pressure of dry mix concrete mortars

    shotcrete

  • 51

    what is the recommended height for the convenient outlets from the floor?

    300mm

  • 52

    which should not be used for its water main pipe?

    ceramic

  • 53

    for its t&b at the ground, which would you connect directly under a floor drain?

    ptrap

  • 54

    when talking about stairs, what is a structural member that supports the treads and risers?

    stringer

  • 55

    lighting provided by adjustable spotlights mounted along a narrow ceiling or wall mounted metal track through which current is concluded. what would you used to empasized an artwork?

    track lighting

  • 56

    he is a registered & licensed architect, who is academically and professionally qualified, & with exceptional or recognized expertise or specialization in any branch of architecture

    consulting architect

  • 57

    what is a composition of a conventional three fixture bath?

    lavatory, water closet, shower/tub

  • 58

    direct lighting that emphasizes an area or an object in a room thereby adding drama or style by highlighting certain aspects what sort of lighting would you use if you have emphasized a feature wall?

    accent lighting

  • 59

    all electrical installations shall conform to the requirements of the

    philippine electrical code

  • 60

    vernacular term for framework

    balangkas

  • 61

    what is the content of the 2004 revised IRR of the presidential decree pd 1096 national building code of the philippines under rule 7?

    classification and general requirements of all buildings by use/occupancy

  • 62

    in lockset, this is the safest door lock recommended for main entry doors

    mortise lockset

  • 63

    nbcp table for minimum setbacks for residential buildings/structures?

    table VIII.2

  • 64

    what is the meaning of FLAR

    floor to lot area ratio

  • 65

    the responsible for advocating the fair and sustainable development, welfare and cultural expression of society's habitat in terms of space forms and historical context

    architect

  • 66

    formula of getting AMVB

    AMBF x BHLmeters

  • 67

    act that requires that workers are provided a safe workplace and free from recognized hazards

    OSHA

  • 68

    a type of glass use in constructing vision door which must be shutter proof to be accident free

    wire glass

  • 69

    as per current IRR of PD1096, the plans and specifications for indoor and outdoor signages shall be prepared, signed and sealed by whom?

    electronics engineer

  • 70

    what is the meaning of the abbreviation ECC, issued by the DENR?

    environmental compliance certificate

  • 71

    what is the minimum entrance steps to the porch if the porch is 100mm below the foyer?

    2

  • 72

    in a building frame, a structural element that is shorter than usual, as a stud above a door opening or below window sill is

    cripple stud

  • 73

    an incomplete form of peeling where paint cracks into the large segments, the edges of which breakaway from the surface while the center remains attached. usually due to repeated application of new coats over old coats

    blistering

  • 74

    which of the given elements is not part of architectural interior services by the architect?

    furniture design and construction

  • 75

    formula of getting TGFA

    all mentioned choices

  • 76

    which of the following is not covered in the framework of minimum standards and requiremnents for buildings under pd1096?

    aesthetic value

  • 77

    subject to existing laws and regulation, who shall determine which street shall have an open sidewalk or an arcaded (covered) sidewalk, or combination of both?

    local planning authority

  • 78

    it refers to the portion of the RROW reckoned from the finished surface of the roadway and/or the sidewalk all the way down into the ground

    RROW below grade

  • 79

    for kitchen storage, what will be the maximum height of wall shelving?

    180cm

  • 80

    considering a 20sqm room, approximately how much horsepower (hp) of air-conditioning is ideal considering 12-15sqm = 1hp?

    1.5hp

  • 81

    beam that project beyond one or both its support?

    continuous beam

  • 82

    interior walls are to be painted. paint with an anti-bacterial formulation that prevents the growth of bacteria would be utilized. which from the following qualities does not match the paint needed?

    ultra high voc

  • 83

    what type of lighting fixture is to be employed at the outdoors at the parking area? note that these architectural outdoor lighting is short, upright ground-mounted unit typically used to provide cutoff type illumination for egress lighting, to light walkways, steps, or other pathways. these types of lighting fixtures typically give off light from the top or the sides

    bollards

  • 84

    what type of lighting fixture is to be employed at the outdoors at the parking area? note that these architectural outdoor lighting is short, upright ground-mounted unit typically used to provide cutoff type illumination for egress lighting, to light walkways, steps, or other pathways. these types of lighting fixtures typically give off light from the top or the sides

    bollards

  • 85

    cubic weight of loose sand

    1442 kg/cu.m

  • 86

    density of dry sand

    1602 kg/cu.m

  • 87

    for the purpose of determining the required wall and opening protection, buildings on the same property and court walls shall be assumed to have a ___ between them.

    property line

  • 88

    for low density residential (R1) uses or occupancies, ___ firewalls are allowed

    no

  • 89

    height of bar counter?

    105mm

  • 90

    height of bar stool?

    750mm

  • 91

    standard height of counter top for filipina women?

    0.80m

  • 92

    width of stairs when less than 10 occupants

    0.75m

  • 93

    additional extra work construction plan by owner

    estimate and add to lump sum

  • 94

    height of door at mezzanine level

    1.80m

  • 95

    height of bathroom door

    1.80m

  • 96

    where should you locate the door jamb for t&b?

    before the threshold outside the t&b

  • 97

    minimum champered length for corner lots

    4.00m

  • Architect Dictums and Philosophies

    Architect Dictums and Philosophies

    LazyXKing · 90問 · 1年前

    Architect Dictums and Philosophies

    Architect Dictums and Philosophies

    90問 • 1年前
    LazyXKing

    FIRE PROTECTION 1

    FIRE PROTECTION 1

    LazyXKing · 100問 · 1年前

    FIRE PROTECTION 1

    FIRE PROTECTION 1

    100問 • 1年前
    LazyXKing

    FIRE PROTECTION 2

    FIRE PROTECTION 2

    LazyXKing · 46問 · 1年前

    FIRE PROTECTION 2

    FIRE PROTECTION 2

    46問 • 1年前
    LazyXKing

    DAY 01am-part1

    DAY 01am-part1

    LazyXKing · 53問 · 1年前

    DAY 01am-part1

    DAY 01am-part1

    53問 • 1年前
    LazyXKing

    DAY 01 pm-part1

    DAY 01 pm-part1

    LazyXKing · 100問 · 1年前

    DAY 01 pm-part1

    DAY 01 pm-part1

    100問 • 1年前
    LazyXKing

    DAY 01 pm-part2

    DAY 01 pm-part2

    LazyXKing · 100問 · 1年前

    DAY 01 pm-part2

    DAY 01 pm-part2

    100問 • 1年前
    LazyXKing

    DAY 01 pm-part3

    DAY 01 pm-part3

    LazyXKing · 99問 · 1年前

    DAY 01 pm-part3

    DAY 01 pm-part3

    99問 • 1年前
    LazyXKing

    RA 9266

    RA 9266

    LazyXKing · 30問 · 1年前

    RA 9266

    RA 9266

    30問 • 1年前
    LazyXKing

    BLDG LAWS & PROFPRAC PREBOARD 1

    BLDG LAWS & PROFPRAC PREBOARD 1

    LazyXKing · 100問 · 1年前

    BLDG LAWS & PROFPRAC PREBOARD 1

    BLDG LAWS & PROFPRAC PREBOARD 1

    100問 • 1年前
    LazyXKing

    BLDG LAWS & PROFPRAC PREBOARD 2

    BLDG LAWS & PROFPRAC PREBOARD 2

    LazyXKing · 100問 · 1年前

    BLDG LAWS & PROFPRAC PREBOARD 2

    BLDG LAWS & PROFPRAC PREBOARD 2

    100問 • 1年前
    LazyXKing

    BLDG LAWS & PROFPRAC PREBOARD 3

    BLDG LAWS & PROFPRAC PREBOARD 3

    LazyXKing · 45問 · 1年前

    BLDG LAWS & PROFPRAC PREBOARD 3

    BLDG LAWS & PROFPRAC PREBOARD 3

    45問 • 1年前
    LazyXKing

    BLDG LAWS & PROFPRAC PREBOARD 4

    BLDG LAWS & PROFPRAC PREBOARD 4

    LazyXKing · 97問 · 1年前

    BLDG LAWS & PROFPRAC PREBOARD 4

    BLDG LAWS & PROFPRAC PREBOARD 4

    97問 • 1年前
    LazyXKing

    VERNACULAR TERMS o1

    VERNACULAR TERMS o1

    LazyXKing · 86問 · 1年前

    VERNACULAR TERMS o1

    VERNACULAR TERMS o1

    86問 • 1年前
    LazyXKing

    VERNACULAR TERMS o2

    VERNACULAR TERMS o2

    LazyXKing · 98問 · 1年前

    VERNACULAR TERMS o2

    VERNACULAR TERMS o2

    98問 • 1年前
    LazyXKing

    VERNACULAR TERMS o3

    VERNACULAR TERMS o3

    LazyXKing · 100問 · 1年前

    VERNACULAR TERMS o3

    VERNACULAR TERMS o3

    100問 • 1年前
    LazyXKing

    VERNACULAR TERMS o4

    VERNACULAR TERMS o4

    LazyXKing · 53問 · 1年前

    VERNACULAR TERMS o4

    VERNACULAR TERMS o4

    53問 • 1年前
    LazyXKing

    HOA RANDOMS MST 01

    HOA RANDOMS MST 01

    LazyXKing · 100問 · 1年前

    HOA RANDOMS MST 01

    HOA RANDOMS MST 01

    100問 • 1年前
    LazyXKing

    HOA RANDOMS MST 02

    HOA RANDOMS MST 02

    LazyXKing · 100問 · 1年前

    HOA RANDOMS MST 02

    HOA RANDOMS MST 02

    100問 • 1年前
    LazyXKing

    HOA MST RANDOMS 03

    HOA MST RANDOMS 03

    LazyXKing · 7問 · 1年前

    HOA MST RANDOMS 03

    HOA MST RANDOMS 03

    7問 • 1年前
    LazyXKing

    問題一覧

  • 1

    architects credo: "I shall endeavor to do my duty in the protection odf our common environment and the preservation of architectural heritage for the sake of the present and future generations"

    legacy

  • 2

    amihan

    northeast

  • 3

    habagat

    southwest

  • 4

    good general lighting color for work areas in the workshop

    daylight

  • 5

    flooring material that have lowest carbon footprint

    baguio stone

  • 6

    minimum knee clearance for a dining area

    55cm

  • 7

    what is the densification of a fill by mechanical means?

    compaction

  • 8

    as per pd1096, wht is the minimum width for access road to interior lots?

    3m

  • 9

    what shall be the minimum distance in meters bt the FFL and ceiling, as compliance under nbcp

    2.70

  • 10

    mechanical systems and/or equipment installations shall be subject to the requirements of the

    philippine mechanical engineering code

  • 11

    what is the highest elevation of the light industrial zone?

    2.9m

  • 12

    rule7&8 of nbcp, what is the meaning of UTS

    utilities transportation and services

  • 13

    which one is not considered part of the GFA?

    underground storage tanks

  • 14

    the size of an average automobile (car) parking slot must be computed at ___ for perpendicular or diagonal parking

    2.5m x 5.0m

  • 15

    what is the best way to provide for the convenience of both people in wheelchair and blind persons?

    railings

  • 16

    what type of perspective is to be employed on the presentation if you wish to show your client the full extent of the main facade?

    one-point perspective

  • 17

    great parking lots are safe, easy access for wheelchairs and maintaining good sight lines. what is the most commonly used and most economical parking layout of parking spaces?

    parallel parking

  • 18

    in waterproofing a balcony, up to where is the extent of the waterproofing installation?

    along the whole floor of the balcony up to the adjacent wall connected

  • 19

    which is considered as non-GFA?

    parking space

  • 20

    RA 9514, what is the meaning of the abbreviation FSEC?

    fire safety evaluation clearance

  • 21

    ceiling, what type of paint is to be applied?

    flat paint so that it wont be glaring

  • 22

    RA 9514, occupant load factor for less concentrated use such as conference rooms, dining rooms, gyms?

    1.4 sqm/person

  • 23

    RA 9514, occupant load factor for concentrated use without fixed seats, such as auditoriums, places of worship, dance floors?

    0.65 sqm/person

  • 24

    for the solar control devices along east and west, what will be the appropriate shading?

    vertical louvres

  • 25

    what is NOT beling among the choices

    condura

  • 26

    PD 1096, which of the following is NOT a basis for assessment of building permit fees?

    land value

  • 27

    rule8 of pd1096, in a high rise apartment or residential condominiums of more than 5 stories, atleast how many passenger elevator be kept on 24 hour constant service?

    1

  • 28

    as per pd1096, what is the minimum air space per person for a habitable room with natural ventilation?

    14cum

  • 29

    which of the following is the most economical architectural flooring material to use on the projects rentable units?

    vinyl strips

  • 30

    waterproofing is required on the roofdeck. what type would be employed?

    membrane type

  • 31

    under bp344, what is the maximum height of the tapping rail if in any case a blind uses the building (for him to be assisted)?

    0.35m

  • 32

    RA 9514, floor level changes shall not vary by more than?

    1.3cm

  • 33

    pd1096 nbcp, what is the portion of the building between floor and ceiling which is wholly or partly below grade and so located that the vertical distance from the grade to floor below is equal to or greater than the vertical distance feom grade to ceiling?

    cellar

  • 34

    what is the term for the required open space left between the outermost face of the building/structure and the property lines?

    yard

  • 35

    if you have to use vinyl for its flooring what brand would you use?

    kent

  • 36

    ratio of a concrete mix would you use for its beam slab?

    1:2:4

  • 37

    what will be the elevation of ground floor, if from parking to walkway has 2 entry steps?

    300mm

  • 38

    what is the common term for the main post at the foot of a stairway or stoop?

    newel

  • 39

    under bp344, what is the distance of the building main entrance to the elevator?

    30m

  • 40

    under bp344, what is the minimum size of an elevator car?

    1.10 x 1.40

  • 41

    what is the standard height of raking handrail?

    90cm-110cm

  • 42

    what is the standard height of window sill from the floor line?

    0.9m

  • 43

    which is not a requirement in applying for building permit?

    latest income tax

  • 44

    what is the recommended dining table length for 6-person seating?

    210cm

  • 45

    the bedroom would be painted with a color that has the tendency of mitigating agressive behavior. what is to be used?

    pink

  • 46

    a front yard may be partly paved/hardscape (converted into a courtyard) to serve as a carport but only for what zoning?

    all mentioned above

  • 47

    what line uses connecting points that have the same elevation?

    contour line

  • 48

    for a 3-fixture t&b, how many floor drain should be provided?

    2

  • 49

    which is not an interior appliance?

    exhaust fan

  • 50

    the placing of concrete using pneumatic pressure of dry mix concrete mortars

    shotcrete

  • 51

    what is the recommended height for the convenient outlets from the floor?

    300mm

  • 52

    which should not be used for its water main pipe?

    ceramic

  • 53

    for its t&b at the ground, which would you connect directly under a floor drain?

    ptrap

  • 54

    when talking about stairs, what is a structural member that supports the treads and risers?

    stringer

  • 55

    lighting provided by adjustable spotlights mounted along a narrow ceiling or wall mounted metal track through which current is concluded. what would you used to empasized an artwork?

    track lighting

  • 56

    he is a registered & licensed architect, who is academically and professionally qualified, & with exceptional or recognized expertise or specialization in any branch of architecture

    consulting architect

  • 57

    what is a composition of a conventional three fixture bath?

    lavatory, water closet, shower/tub

  • 58

    direct lighting that emphasizes an area or an object in a room thereby adding drama or style by highlighting certain aspects what sort of lighting would you use if you have emphasized a feature wall?

    accent lighting

  • 59

    all electrical installations shall conform to the requirements of the

    philippine electrical code

  • 60

    vernacular term for framework

    balangkas

  • 61

    what is the content of the 2004 revised IRR of the presidential decree pd 1096 national building code of the philippines under rule 7?

    classification and general requirements of all buildings by use/occupancy

  • 62

    in lockset, this is the safest door lock recommended for main entry doors

    mortise lockset

  • 63

    nbcp table for minimum setbacks for residential buildings/structures?

    table VIII.2

  • 64

    what is the meaning of FLAR

    floor to lot area ratio

  • 65

    the responsible for advocating the fair and sustainable development, welfare and cultural expression of society's habitat in terms of space forms and historical context

    architect

  • 66

    formula of getting AMVB

    AMBF x BHLmeters

  • 67

    act that requires that workers are provided a safe workplace and free from recognized hazards

    OSHA

  • 68

    a type of glass use in constructing vision door which must be shutter proof to be accident free

    wire glass

  • 69

    as per current IRR of PD1096, the plans and specifications for indoor and outdoor signages shall be prepared, signed and sealed by whom?

    electronics engineer

  • 70

    what is the meaning of the abbreviation ECC, issued by the DENR?

    environmental compliance certificate

  • 71

    what is the minimum entrance steps to the porch if the porch is 100mm below the foyer?

    2

  • 72

    in a building frame, a structural element that is shorter than usual, as a stud above a door opening or below window sill is

    cripple stud

  • 73

    an incomplete form of peeling where paint cracks into the large segments, the edges of which breakaway from the surface while the center remains attached. usually due to repeated application of new coats over old coats

    blistering

  • 74

    which of the given elements is not part of architectural interior services by the architect?

    furniture design and construction

  • 75

    formula of getting TGFA

    all mentioned choices

  • 76

    which of the following is not covered in the framework of minimum standards and requiremnents for buildings under pd1096?

    aesthetic value

  • 77

    subject to existing laws and regulation, who shall determine which street shall have an open sidewalk or an arcaded (covered) sidewalk, or combination of both?

    local planning authority

  • 78

    it refers to the portion of the RROW reckoned from the finished surface of the roadway and/or the sidewalk all the way down into the ground

    RROW below grade

  • 79

    for kitchen storage, what will be the maximum height of wall shelving?

    180cm

  • 80

    considering a 20sqm room, approximately how much horsepower (hp) of air-conditioning is ideal considering 12-15sqm = 1hp?

    1.5hp

  • 81

    beam that project beyond one or both its support?

    continuous beam

  • 82

    interior walls are to be painted. paint with an anti-bacterial formulation that prevents the growth of bacteria would be utilized. which from the following qualities does not match the paint needed?

    ultra high voc

  • 83

    what type of lighting fixture is to be employed at the outdoors at the parking area? note that these architectural outdoor lighting is short, upright ground-mounted unit typically used to provide cutoff type illumination for egress lighting, to light walkways, steps, or other pathways. these types of lighting fixtures typically give off light from the top or the sides

    bollards

  • 84

    what type of lighting fixture is to be employed at the outdoors at the parking area? note that these architectural outdoor lighting is short, upright ground-mounted unit typically used to provide cutoff type illumination for egress lighting, to light walkways, steps, or other pathways. these types of lighting fixtures typically give off light from the top or the sides

    bollards

  • 85

    cubic weight of loose sand

    1442 kg/cu.m

  • 86

    density of dry sand

    1602 kg/cu.m

  • 87

    for the purpose of determining the required wall and opening protection, buildings on the same property and court walls shall be assumed to have a ___ between them.

    property line

  • 88

    for low density residential (R1) uses or occupancies, ___ firewalls are allowed

    no

  • 89

    height of bar counter?

    105mm

  • 90

    height of bar stool?

    750mm

  • 91

    standard height of counter top for filipina women?

    0.80m

  • 92

    width of stairs when less than 10 occupants

    0.75m

  • 93

    additional extra work construction plan by owner

    estimate and add to lump sum

  • 94

    height of door at mezzanine level

    1.80m

  • 95

    height of bathroom door

    1.80m

  • 96

    where should you locate the door jamb for t&b?

    before the threshold outside the t&b

  • 97

    minimum champered length for corner lots

    4.00m