  • 1

    min. EXIT DOOR width

    0.71 m

  • 2

    min. FLOOR to CEILING height

    2.30 m

  • 3

    max. STAIR RISE height for CLASS A stair

    0.19 m

  • 4

    max. HEIGHT between landings for CLASS A stair.

    2.75 m

  • 5

    min. HEADROOM for CLASS A and B stairs

    2.00 m

  • 6

    UNIT AREA per person for WAITING AREAS or STANDING ROOMS.

    0.28 sqm

  • 7

    NUMBER of EXITS for place of assembly for 1000 OCCUPANTS

    4 exits

  • 8

    TRAVEL DISTANCE to an exit without fire sprinkler system.

    46 m

  • 9

    TRAVEL DISTANCE to an exit with fire sprinkler system

    61 m

  • 10

    MIN. SPACING of rows of seats from BACK to BACK for a public assembly building

    0.83 m

  • 11

    max. number of seats in a row in between aisles

    14 seats

  • 12

    max. number of seats in a row opening on to an AISLE at ONE SIDE

    7 seats

  • 13

    standard width of a seat without dividing arms for places of assembly

    60 cm

  • 14

    min. WIDTH of an AISLE serving an occupant of 60

    0.91 cm

  • 15

    min. HEADROOM created by ANY PROJECTION from ceiling

    2.00 m

  • 16

    MIN. clear width of TURNSTILES

    56 cm

  • 17

    min. DIMENSION of LANDING in DIRECTION of travel for class A and B

    112 cm

  • 18

    min. NUMBER of RISERS in any one (1) FLIGHT of stairs

    3 risers

  • 19

    min. HEIGHT of HANDRAIL above the UPPER SURFACE of the THREAD

    76 cm

  • 20

    min. CLEARANCE of HANDRAIL from any WALL

    38 mm

  • 21

    min. HEIGHT of a GUARDRAIL

    91 cm

  • 22

    max. HEIGHT of GUARDRAIL

    106 cm

  • 23

    min. INNER RADIUS of MONUMENTAL STAIR

    7.50 m

  • 24

    max. HEIGHT between LANDINGS for a fire escape stair - existing stairs

    3.66 m

  • 25

    min. HEADROOM CLEARANCE for a fire escape stair - existing stairs

    2.13 m

  • 26

    min. HEADROOM CLEARANCE for fire escape stair - small buildings

    1.98 m

  • 27

    number of EXITS for PLACE OF ASSEMBLY for 600-1000 occupants

    3 exits

  • 28

    max. occupant load for a CLASS C PUBLIC ASSEMBLY

    50-300

  • 29

    min. number of EXIT for an INSTITUTIONAL TYPE OF STRUCTURE

    2 exits

  • 30

    max. TRAVEL DISTANCE between ROOM DOOR intended as EXIT ACCESS and EXIT with sprinkler system - INSTITUTIONAL USE

    30 m

  • 31

    max. TRAVEL DISTANCE from DOOR to any room to EXIT - HOTELS with sprinklers

    30 m

  • 32

    max. TRAVEL DISTANCE from the MAIN ENTRANCE DOOR to EXIT - APARTMENT with sprinkler

    31 m

  • 33

    min. INCREASE IN WIDTH for an AISLE per linear meter

    2.5 cm

  • 34

    min WIDTH OF AN AISLE serving an occupant of 60 OR MORE serving one side - PUBLIC ASSEMBLY BUILDING

    91 cm

  • 35

    min. WIDTH OF AN AISLE serving an occupant of 60 OR MORE serving two sides - PUBLIC ASSEMBLY BUILDING

    1 m

  • 36

    min. WIDTH OF AN AISLE serving an occupant of BELOW 60 - PUBLIC ASSEMBLY BUILDING

    76 cm

  • 37

    min. WIDTH OF AN AISLE - EDUCATIONAL USE BUILDING

    1.80 m

  • 38

    occupant load per person - LABORATORIES

    4.60 sqm

  • 39

    min. WIDTH OF AN AISLE - HOSPITALS/NURSING HOMES

    2.44 m

  • 40

    min. WIDTH OF AN AISLE - CUSTODIAL CARE INSTITUTIONS

    1.83 m

  • 41

    min. WIDTH OF AN AISLE - BUSINESS USE STRUCTURE

    112 cm

  • 42

    min. WIDTH OF AN AISLE - INDUSTRIAL BUILDING

    112 cm

  • 43

    min. WIDTH of CLASS A RAMP

    112 cm

  • 44

    min. WIDTH of any BALCONY OR BRIDGE

    112 cm

  • 45

    max. RISE OF ANY FLOOR from the BALCONY floor to which an ACCESS DOOR LEADS

    20.3 cm

  • 46

    max. VERTICAL HEIGHT in FLOORS - ESCALATOR

    1 floor

  • 47

    min. WIDTH of fire escape stair - exiting stairs

    55.9 cm

  • 48

    min. WIDTH OF LANDING for a fire escape stair - existing stair

    55.9 cm

  • 49

    min. TREAD for a fire escape stair - small buidings

    15.25 cm

  • 50

    max. RISE of fire esxape stair - small building

    30.5 cm

  • 51

    max. RISE of fire escape stair - existing stairs

    22.9 cm

  • 52

    buildings/structures 15 METERS OR MORE in height

    High Rise Building

  • 53

    a kind of STABLE EXPLOSIVE COMPOUND which EXPLODES by PERCUSSION

    Fulminate

  • 54

    LIBRARIES are classified under what classification of occupancy

    Business

  • 55

    an AIR COMPARTMENT or CHAMBER to which 1 or more ducts are connected and which form part of an AIR DISTRIBUTION SYSTEM

    Plenum

  • 56

    buildings or structures used for the STORAGE OF EXPLOSIVES, SHELLS, PROJECTILES, ETC.

    Explosive Magazine

  • 57

    COURTROOMS with an occupant load of MORE THAN 100 are classified under what classification of occupancy

    Assembly

  • 58

    JAILS are classified under what classification of occupancy

    Institutional

  • 59

    ARMORIES with an occupant load of more than 100 are classified under what classification of occupancy

    Assembly

  • 60

    rooms where BALED, BUNDLED or PILED materials segregated into desired sizes or groups

    Picking rooms

  • 61

    descriptive of ANY SUBSTANCE THAT IGNITES SPONTANEOUSLY when exposed ti air

    Phyrophoric

  • 62

    a process where a PIECE OF METAL IS HEATED PRIOR to changing its shape and dimension

    Forging

  • 63

    a FINELY POWDERED substance which, when mixed with air in the proper proportion and ignited will cause an EXPLOSION

    Dust

  • 64

    min. FIRE RESISTANCE RATING for a FIREWALL

    4 hours

  • 65

    a CONTINOUS PASSAGEWAY for the TRANSMISSION OF AIR

    Duct system

  • 66

    temperature rating at FLASH POINT

    37.8 deg.C (100deg.F)

  • 67

    a CLASS OF FIRE with flammable liquid and gasses

    Class B

  • 68

    the TEMPERATURE at which a liquid is TRANSFORMED or CONVERTED into VAPOR

    Boiling Point

  • 69

    a material that readily yields oxygen in quantities sufficient TO STIMULATE or SUPPORT COMBUSTION

    Oxidizing material

  • 70

    the PROCESS of first raising the temperature to separate the more volatile from leas volatile parts and then cooling and condensing the result vapor so as to produce a nearly purified substance

    Distillation

  • 71

    a GAS, FUME, or VAPOR used for the DESTRUCTION or CONTROL of insects, fungi, vermin, germs, rodents or other pests

    Fumigant

  • 72

    min. WIDTH OF ANY DRIVEWAY in and around a lumber yard/piles

    4.50 m

  • 73

    min. HEIGHT OF FENCE for a LUMBER YARD for EXTERIOR STORAGE of LUMBERS

    1.80 m

  • 74

    max. width of SUMPS for the retension of oil and petroleum product

    3.70 mts

  • 75

    for refineries, distelleries, and chemical plants, the minimum height for a FENCE.

    1.50 mts

  • 76

    minimum TRAVEL DISTANCE from any individual room subject to occupancy by not more 15.00 mts

    6 persons

  • 77

    max. distance of travel from the HIGH HAZARD AREA to an EXIT.

    23 mts

  • 78

    minimum distance of an incinerator from any structure used other than a single family dwelling

    3 mts

  • 79

    maximum reduction in width of a stair by a handrail

    9 cms

  • 80

    max force in kilograms required for a panic hardware

    7 kgs

  • 81

    min height reqd for a panic hardware installation

    76 cms

  • 82

    max height reqd for a panic hardware installation

    112 cms

  • 83

    min door width of a single door in a door way

    71 cms

  • 84

    max change in elev btween the interior of a door to the outside of it othr than a balcony

    20.5 cms

  • 85

    min width of CLASS B ramp

    76 cms

  • 86

    min width of CLASS A ramp

    112 cms

  • 87

    max horizontal projection of a handrail over a stair

    38 mm

  • 88

    under what classification of occupancy does drugstores fall

    mercantile

  • 89

    any material which by its nature or as a result of its reaction with other elements produces a rapid drop in temperature of the immediate surrounding

    cryogenic

  • 90

    classification of occupancy - pool rooms

    assembly

  • 91

    classification of occupancy - home for the aged

    institutional

  • 92

    classification of occupancy - refineries

    industrial

  • 93

    classification of occupancy - court houses

    business

  • 94

    classification of occupancy - museums

    assembly

  • 95

    classification of occupancy - town halls

    business

  • 96

    a continuous and unobstructed route of exit from any point in a building to a public way

    means of egress

  • 97

    class of fire - ordinary combustile metals, such as magnesium, sodium, potassium, and other similar materials

    Class D

  • 98

    class of fire - ordinary combustile materials, such as wood, papers, cloth, rubber, and plastics.

    Class A

  • 99

    max height of a handrail

    86.5 cms

  • 100

    the time duration that a material or construction can widthstand the effect of standard fire test is known as

    fire resistance rating