問題一覧
1
min. WIDTH of fire escape stair - exiting stairs
55.9 cm
2
max. HEIGHT of GUARDRAIL
106 cm
3
under what classification of occupancy does drugstores fall
mercantile
4
min. HEIGHT of a GUARDRAIL
91 cm
5
max. RISE OF ANY FLOOR from the BALCONY floor to which an ACCESS DOOR LEADS
20.3 cm
6
min. number of EXIT for an INSTITUTIONAL TYPE OF STRUCTURE
2 exits
7
max. number of seats in a row opening on to an AISLE at ONE SIDE
7 seats
8
NUMBER of EXITS for place of assembly for 1000 OCCUPANTS
4 exits
9
max. RISE of fire escape stair - existing stairs
22.9 cm
10
max. TRAVEL DISTANCE from DOOR to any room to EXIT - HOTELS with sprinklers
30 m
11
a CLASS OF FIRE with flammable liquid and gasses
Class B
12
max. HEIGHT between landings for CLASS A stair.
2.75 m
13
max height reqd for a panic hardware installation
112 cms
14
min. DIMENSION of LANDING in DIRECTION of travel for class A and B
112 cm
15
min WIDTH OF AN AISLE serving an occupant of 60 OR MORE serving one side - PUBLIC ASSEMBLY BUILDING
91 cm
16
max. RISE of fire esxape stair - small building
30.5 cm
17
min. INCREASE IN WIDTH for an AISLE per linear meter
2.5 cm
18
min. HEADROOM created by ANY PROJECTION from ceiling
2.00 m
19
maximum reduction in width of a stair by a handrail
9 cms
20
an AIR COMPARTMENT or CHAMBER to which 1 or more ducts are connected and which form part of an AIR DISTRIBUTION SYSTEM
Plenum
21
min. WIDTH of an AISLE serving an occupant of 60
0.91 cm
22
max. TRAVEL DISTANCE between ROOM DOOR intended as EXIT ACCESS and EXIT with sprinkler system - INSTITUTIONAL USE
30 m
23
the PROCESS of first raising the temperature to separate the more volatile from leas volatile parts and then cooling and condensing the result vapor so as to produce a nearly purified substance
Distillation
24
max. STAIR RISE height for CLASS A stair
0.19 m
25
min. WIDTH OF AN AISLE - EDUCATIONAL USE BUILDING
1.80 m
26
descriptive of ANY SUBSTANCE THAT IGNITES SPONTANEOUSLY when exposed ti air
Phyrophoric
27
COURTROOMS with an occupant load of MORE THAN 100 are classified under what classification of occupancy
Assembly
28
classification of occupancy - home for the aged
institutional
29
for refineries, distelleries, and chemical plants, the minimum height for a FENCE.
1.50 mts
30
LIBRARIES are classified under what classification of occupancy
Business
31
MIN. clear width of TURNSTILES
56 cm
32
class of fire - ordinary combustile metals, such as magnesium, sodium, potassium, and other similar materials
Class D
33
a material that readily yields oxygen in quantities sufficient TO STIMULATE or SUPPORT COMBUSTION
Oxidizing material
34
max. distance of travel from the HIGH HAZARD AREA to an EXIT.
23 mts
35
min. CLEARANCE of HANDRAIL from any WALL
38 mm
36
max. width of SUMPS for the retension of oil and petroleum product
3.70 mts
37
min. WIDTH OF AN AISLE - BUSINESS USE STRUCTURE
112 cm
38
min. WIDTH of any BALCONY OR BRIDGE
112 cm
39
min door width of a single door in a door way
71 cms
40
ARMORIES with an occupant load of more than 100 are classified under what classification of occupancy
Assembly
41
TRAVEL DISTANCE to an exit with fire sprinkler system
61 m
42
min. HEIGHT OF FENCE for a LUMBER YARD for EXTERIOR STORAGE of LUMBERS
1.80 m
43
MIN. SPACING of rows of seats from BACK to BACK for a public assembly building
0.83 m
44
max. HEIGHT between LANDINGS for a fire escape stair - existing stairs
3.66 m
45
rooms where BALED, BUNDLED or PILED materials segregated into desired sizes or groups
Picking rooms
46
min. HEIGHT of HANDRAIL above the UPPER SURFACE of the THREAD
76 cm
47
classification of occupancy - pool rooms
assembly
48
the TEMPERATURE at which a liquid is TRANSFORMED or CONVERTED into VAPOR
Boiling Point
49
min. WIDTH OF AN AISLE serving an occupant of 60 OR MORE serving two sides - PUBLIC ASSEMBLY BUILDING
1 m
50
max. occupant load for a CLASS C PUBLIC ASSEMBLY
50-300
51
max. TRAVEL DISTANCE from the MAIN ENTRANCE DOOR to EXIT - APARTMENT with sprinkler
31 m
52
max. number of seats in a row in between aisles
14 seats
53
classification of occupancy - museums
assembly
54
class of fire - ordinary combustile materials, such as wood, papers, cloth, rubber, and plastics.
Class A
55
min. WIDTH OF AN AISLE - CUSTODIAL CARE INSTITUTIONS
1.83 m
56
max change in elev btween the interior of a door to the outside of it othr than a balcony
20.5 cms
57
min. NUMBER of RISERS in any one (1) FLIGHT of stairs
3 risers
58
max force in kilograms required for a panic hardware
7 kgs
59
UNIT AREA per person for WAITING AREAS or STANDING ROOMS.
0.28 sqm
60
JAILS are classified under what classification of occupancy
Institutional
61
max horizontal projection of a handrail over a stair
38 mm
62
buildings/structures 15 METERS OR MORE in height
High Rise Building
63
a CONTINOUS PASSAGEWAY for the TRANSMISSION OF AIR
Duct system
64
buildings or structures used for the STORAGE OF EXPLOSIVES, SHELLS, PROJECTILES, ETC.
Explosive Magazine
65
a FINELY POWDERED substance which, when mixed with air in the proper proportion and ignited will cause an EXPLOSION
Dust
66
any material which by its nature or as a result of its reaction with other elements produces a rapid drop in temperature of the immediate surrounding
cryogenic
67
min. WIDTH OF AN AISLE - HOSPITALS/NURSING HOMES
2.44 m
68
min. HEADROOM CLEARANCE for fire escape stair - small buildings
1.98 m
69
minimum TRAVEL DISTANCE from any individual room subject to occupancy by not more 15.00 mts
6 persons
70
a GAS, FUME, or VAPOR used for the DESTRUCTION or CONTROL of insects, fungi, vermin, germs, rodents or other pests
Fumigant
71
max. VERTICAL HEIGHT in FLOORS - ESCALATOR
1 floor
72
min. FLOOR to CEILING height
2.30 m
73
min. INNER RADIUS of MONUMENTAL STAIR
7.50 m
74
min width of CLASS A ramp
112 cms
75
max height of a handrail
86.5 cms
76
min width of CLASS B ramp
76 cms
77
min. WIDTH OF AN AISLE serving an occupant of BELOW 60 - PUBLIC ASSEMBLY BUILDING
76 cm
78
occupant load per person - LABORATORIES
4.60 sqm
79
min height reqd for a panic hardware installation
76 cms
80
classification of occupancy - court houses
business
81
min. HEADROOM for CLASS A and B stairs
2.00 m
82
min. WIDTH of CLASS A RAMP
112 cm
83
minimum distance of an incinerator from any structure used other than a single family dwelling
3 mts
84
standard width of a seat without dividing arms for places of assembly
60 cm
85
min. WIDTH OF AN AISLE - INDUSTRIAL BUILDING
112 cm
86
min. EXIT DOOR width
0.71 m
87
classification of occupancy - town halls
business
88
min. WIDTH OF ANY DRIVEWAY in and around a lumber yard/piles
4.50 m
89
temperature rating at FLASH POINT
37.8 deg.C (100deg.F)
90
a kind of STABLE EXPLOSIVE COMPOUND which EXPLODES by PERCUSSION
Fulminate
91
classification of occupancy - refineries
industrial
92
a process where a PIECE OF METAL IS HEATED PRIOR to changing its shape and dimension
Forging
93
number of EXITS for PLACE OF ASSEMBLY for 600-1000 occupants
3 exits
94
min. FIRE RESISTANCE RATING for a FIREWALL
4 hours
95
min. HEADROOM CLEARANCE for a fire escape stair - existing stairs
2.13 m
96
TRAVEL DISTANCE to an exit without fire sprinkler system.
46 m
97
min. TREAD for a fire escape stair - small buidings
15.25 cm
98
a continuous and unobstructed route of exit from any point in a building to a public way
means of egress
99
min. WIDTH OF LANDING for a fire escape stair - existing stair
55.9 cm
100
the time duration that a material or construction can widthstand the effect of standard fire test is known as
fire resistance rating