問題一覧
1
min. EXIT DOOR width
0.71 m
2
min. FLOOR to CEILING height
2.30 m
3
max. STAIR RISE height for CLASS A stair
0.19 m
4
max. HEIGHT between landings for CLASS A stair.
2.75 m
5
min. HEADROOM for CLASS A and B stairs
2.00 m
6
UNIT AREA per person for WAITING AREAS or STANDING ROOMS.
0.28 sqm
7
NUMBER of EXITS for place of assembly for 1000 OCCUPANTS
4 exits
8
TRAVEL DISTANCE to an exit without fire sprinkler system.
46 m
9
TRAVEL DISTANCE to an exit with fire sprinkler system
61 m
10
MIN. SPACING of rows of seats from BACK to BACK for a public assembly building
0.83 m
11
max. number of seats in a row in between aisles
14 seats
12
max. number of seats in a row opening on to an AISLE at ONE SIDE
7 seats
13
standard width of a seat without dividing arms for places of assembly
60 cm
14
min. WIDTH of an AISLE serving an occupant of 60
0.91 cm
15
min. HEADROOM created by ANY PROJECTION from ceiling
2.00 m
16
MIN. clear width of TURNSTILES
56 cm
17
min. DIMENSION of LANDING in DIRECTION of travel for class A and B
112 cm
18
min. NUMBER of RISERS in any one (1) FLIGHT of stairs
3 risers
19
min. HEIGHT of HANDRAIL above the UPPER SURFACE of the THREAD
76 cm
20
min. CLEARANCE of HANDRAIL from any WALL
38 mm
21
min. HEIGHT of a GUARDRAIL
91 cm
22
max. HEIGHT of GUARDRAIL
106 cm
23
min. INNER RADIUS of MONUMENTAL STAIR
7.50 m
24
max. HEIGHT between LANDINGS for a fire escape stair - existing stairs
3.66 m
25
min. HEADROOM CLEARANCE for a fire escape stair - existing stairs
2.13 m
26
min. HEADROOM CLEARANCE for fire escape stair - small buildings
1.98 m
27
number of EXITS for PLACE OF ASSEMBLY for 600-1000 occupants
3 exits
28
max. occupant load for a CLASS C PUBLIC ASSEMBLY
50-300
29
min. number of EXIT for an INSTITUTIONAL TYPE OF STRUCTURE
2 exits
30
max. TRAVEL DISTANCE between ROOM DOOR intended as EXIT ACCESS and EXIT with sprinkler system - INSTITUTIONAL USE
30 m
31
max. TRAVEL DISTANCE from DOOR to any room to EXIT - HOTELS with sprinklers
30 m
32
max. TRAVEL DISTANCE from the MAIN ENTRANCE DOOR to EXIT - APARTMENT with sprinkler
31 m
33
min. INCREASE IN WIDTH for an AISLE per linear meter
2.5 cm
34
min WIDTH OF AN AISLE serving an occupant of 60 OR MORE serving one side - PUBLIC ASSEMBLY BUILDING
91 cm
35
min. WIDTH OF AN AISLE serving an occupant of 60 OR MORE serving two sides - PUBLIC ASSEMBLY BUILDING
1 m
36
min. WIDTH OF AN AISLE serving an occupant of BELOW 60 - PUBLIC ASSEMBLY BUILDING
76 cm
37
min. WIDTH OF AN AISLE - EDUCATIONAL USE BUILDING
1.80 m
38
occupant load per person - LABORATORIES
4.60 sqm
39
min. WIDTH OF AN AISLE - HOSPITALS/NURSING HOMES
2.44 m
40
min. WIDTH OF AN AISLE - CUSTODIAL CARE INSTITUTIONS
1.83 m
41
min. WIDTH OF AN AISLE - BUSINESS USE STRUCTURE
112 cm
42
min. WIDTH OF AN AISLE - INDUSTRIAL BUILDING
112 cm
43
min. WIDTH of CLASS A RAMP
112 cm
44
min. WIDTH of any BALCONY OR BRIDGE
112 cm
45
max. RISE OF ANY FLOOR from the BALCONY floor to which an ACCESS DOOR LEADS
20.3 cm
46
max. VERTICAL HEIGHT in FLOORS - ESCALATOR
1 floor
47
min. WIDTH of fire escape stair - exiting stairs
55.9 cm
48
min. WIDTH OF LANDING for a fire escape stair - existing stair
55.9 cm
49
min. TREAD for a fire escape stair - small buidings
15.25 cm
50
max. RISE of fire esxape stair - small building
30.5 cm
51
max. RISE of fire escape stair - existing stairs
22.9 cm
52
buildings/structures 15 METERS OR MORE in height
High Rise Building
53
a kind of STABLE EXPLOSIVE COMPOUND which EXPLODES by PERCUSSION
Fulminate
54
LIBRARIES are classified under what classification of occupancy
Business
55
an AIR COMPARTMENT or CHAMBER to which 1 or more ducts are connected and which form part of an AIR DISTRIBUTION SYSTEM
Plenum
56
buildings or structures used for the STORAGE OF EXPLOSIVES, SHELLS, PROJECTILES, ETC.
Explosive Magazine
57
COURTROOMS with an occupant load of MORE THAN 100 are classified under what classification of occupancy
Assembly
58
JAILS are classified under what classification of occupancy
Institutional
59
ARMORIES with an occupant load of more than 100 are classified under what classification of occupancy
Assembly
60
rooms where BALED, BUNDLED or PILED materials segregated into desired sizes or groups
Picking rooms
61
descriptive of ANY SUBSTANCE THAT IGNITES SPONTANEOUSLY when exposed ti air
Phyrophoric
62
a process where a PIECE OF METAL IS HEATED PRIOR to changing its shape and dimension
Forging
63
a FINELY POWDERED substance which, when mixed with air in the proper proportion and ignited will cause an EXPLOSION
Dust
64
min. FIRE RESISTANCE RATING for a FIREWALL
4 hours
65
a CONTINOUS PASSAGEWAY for the TRANSMISSION OF AIR
Duct system
66
temperature rating at FLASH POINT
37.8 deg.C (100deg.F)
67
a CLASS OF FIRE with flammable liquid and gasses
Class B
68
the TEMPERATURE at which a liquid is TRANSFORMED or CONVERTED into VAPOR
Boiling Point
69
a material that readily yields oxygen in quantities sufficient TO STIMULATE or SUPPORT COMBUSTION
Oxidizing material
70
the PROCESS of first raising the temperature to separate the more volatile from leas volatile parts and then cooling and condensing the result vapor so as to produce a nearly purified substance
Distillation
71
a GAS, FUME, or VAPOR used for the DESTRUCTION or CONTROL of insects, fungi, vermin, germs, rodents or other pests
Fumigant
72
min. WIDTH OF ANY DRIVEWAY in and around a lumber yard/piles
4.50 m
73
min. HEIGHT OF FENCE for a LUMBER YARD for EXTERIOR STORAGE of LUMBERS
1.80 m
74
max. width of SUMPS for the retension of oil and petroleum product
3.70 mts
75
for refineries, distelleries, and chemical plants, the minimum height for a FENCE.
1.50 mts
76
minimum TRAVEL DISTANCE from any individual room subject to occupancy by not more 15.00 mts
6 persons
77
max. distance of travel from the HIGH HAZARD AREA to an EXIT.
23 mts
78
minimum distance of an incinerator from any structure used other than a single family dwelling
3 mts
79
maximum reduction in width of a stair by a handrail
9 cms
80
max force in kilograms required for a panic hardware
7 kgs
81
min height reqd for a panic hardware installation
76 cms
82
max height reqd for a panic hardware installation
112 cms
83
min door width of a single door in a door way
71 cms
84
max change in elev btween the interior of a door to the outside of it othr than a balcony
20.5 cms
85
min width of CLASS B ramp
76 cms
86
min width of CLASS A ramp
112 cms
87
max horizontal projection of a handrail over a stair
38 mm
88
under what classification of occupancy does drugstores fall
mercantile
89
any material which by its nature or as a result of its reaction with other elements produces a rapid drop in temperature of the immediate surrounding
cryogenic
90
classification of occupancy - pool rooms
assembly
91
classification of occupancy - home for the aged
institutional
92
classification of occupancy - refineries
industrial
93
classification of occupancy - court houses
business
94
classification of occupancy - museums
assembly
95
classification of occupancy - town halls
business
96
a continuous and unobstructed route of exit from any point in a building to a public way
means of egress
97
class of fire - ordinary combustile metals, such as magnesium, sodium, potassium, and other similar materials
Class D
98
class of fire - ordinary combustile materials, such as wood, papers, cloth, rubber, and plastics.
Class A
99
max height of a handrail
86.5 cms
100
the time duration that a material or construction can widthstand the effect of standard fire test is known as
fire resistance rating