ログイン

c7.9

c7.9
8問 • 1年前
  • Aljuboory
  • 通報

    問題一覧

  • 1

    Aluminium tubing with outside diameters less

    than 3/8 in [0.952 cm] must have a double flare

  • 2

    Flexible hoses are pressure tested to

    1.5% times the maximum working pressure. Test with the normal system fluid or paraffin.

  • 3

    Pipe a way From control rods and rigid moving parts is

    = 18 mm (0.75 in)

  • 4

    A small amount of flattening in bends is acceptable, but should not exceed an amount such that the small diameter of the flattened portion is

    less than 75% of the original outside diameter.

  • 5

    Pass a ball through the pipe from each end in turn. The ball diameter should be at

    least 80% of the diameter of the pipe. Flow test may be specified

  • 6

    The parts required to make up a flared-tube fitting

    are sleeve and nut

  • 7

    Fretting corrosion on a braided pipe would mean it was

    unserviceable and should be replaced

  • 8

    Flareless-Tube Fittings The fitting consists of three parts;

    a body, a sleeve, and a nut

  • mod 4 test

    mod 4 test

    Aljuboory · 81問 · 1年前

    mod 4 test

    mod 4 test

    81問 • 1年前
    Aljuboory

    mod 2 test

    mod 2 test

    Aljuboory · 100問 · 1年前

    mod 2 test

    mod 2 test

    100問 • 1年前
    Aljuboory

    mod 2,2

    mod 2,2

    Aljuboory · 94問 · 1年前

    mod 2,2

    mod 2,2

    94問 • 1年前
    Aljuboory

    mod 6,1

    mod 6,1

    Aljuboory · 277問 · 1年前

    mod 6,1

    mod 6,1

    277問 • 1年前
    Aljuboory

    c7.1

    c7.1

    Aljuboory · 18問 · 1年前

    c7.1

    c7.1

    18問 • 1年前
    Aljuboory

    c7.2

    c7.2

    Aljuboory · 11問 · 1年前

    c7.2

    c7.2

    11問 • 1年前
    Aljuboory

    c7.3

    c7.3

    Aljuboory · 36問 · 1年前

    c7.3

    c7.3

    36問 • 1年前
    Aljuboory

    c7,4

    c7,4

    Aljuboory · 20問 · 1年前

    c7,4

    c7,4

    20問 • 1年前
    Aljuboory

    c7.5

    c7.5

    Aljuboory · 11問 · 1年前

    c7.5

    c7.5

    11問 • 1年前
    Aljuboory

    c7.7

    c7.7

    Aljuboory · 17問 · 1年前

    c7.7

    c7.7

    17問 • 1年前
    Aljuboory

    c7.8

    c7.8

    Aljuboory · 5問 · 1年前

    c7.8

    c7.8

    5問 • 1年前
    Aljuboory

    7.10

    7.10

    Aljuboory · 12問 · 1年前

    7.10

    7.10

    12問 • 1年前
    Aljuboory

    c7.11

    c7.11

    Aljuboory · 6問 · 1年前

    c7.11

    c7.11

    6問 • 1年前
    Aljuboory

    c7.12

    c7.12

    Aljuboory · 10問 · 1年前

    c7.12

    c7.12

    10問 • 1年前
    Aljuboory

    c7.13

    c7.13

    Aljuboory · 10問 · 1年前

    c7.13

    c7.13

    10問 • 1年前
    Aljuboory

    c7.14

    c7.14

    Aljuboory · 17問 · 1年前

    c7.14

    c7.14

    17問 • 1年前
    Aljuboory

    c7.15

    c7.15

    Aljuboory · 20問 · 1年前

    c7.15

    c7.15

    20問 • 1年前
    Aljuboory

    c7.16

    c7.16

    Aljuboory · 14問 · 1年前

    c7.16

    c7.16

    14問 • 1年前
    Aljuboory

    c7.17

    c7.17

    Aljuboory · 14問 · 1年前

    c7.17

    c7.17

    14問 • 1年前
    Aljuboory

    c7.18

    c7.18

    Aljuboory · 36問 · 1年前

    c7.18

    c7.18

    36問 • 1年前
    Aljuboory

    c7.19

    c7.19

    Aljuboory · 11問 · 1年前

    c7.19

    c7.19

    11問 • 1年前
    Aljuboory

    c7.20

    c7.20

    Aljuboory · 18問 · 1年前

    c7.20

    c7.20

    18問 • 1年前
    Aljuboory

    問題一覧

  • 1

    Aluminium tubing with outside diameters less

    than 3/8 in [0.952 cm] must have a double flare

  • 2

    Flexible hoses are pressure tested to

    1.5% times the maximum working pressure. Test with the normal system fluid or paraffin.

  • 3

    Pipe a way From control rods and rigid moving parts is

    = 18 mm (0.75 in)

  • 4

    A small amount of flattening in bends is acceptable, but should not exceed an amount such that the small diameter of the flattened portion is

    less than 75% of the original outside diameter.

  • 5

    Pass a ball through the pipe from each end in turn. The ball diameter should be at

    least 80% of the diameter of the pipe. Flow test may be specified

  • 6

    The parts required to make up a flared-tube fitting

    are sleeve and nut

  • 7

    Fretting corrosion on a braided pipe would mean it was

    unserviceable and should be replaced

  • 8

    Flareless-Tube Fittings The fitting consists of three parts;

    a body, a sleeve, and a nut