What is the estimated sewage flow rate of bowling alleys with snack bar only?283.9 LpD per lane
What is the storage factor for self-service auto washers?1.5
Minimum dimension of a sand interceptor's inlet opening0.2 sq.m.
A group vent pipe that connects to the vent stackCircuit Vent
Prohibited vent pipe material below groundGalvanized Wrought Iron
Minimum spacing between trenches or leaching beds1.20 m
Which among the choices is a prohibited trap?Crown trap
Normally in Manila, the rainfall intensity used is _____.102 mm
Maximum number of slip joint fitting that may be used on the outlet side of a trap1
Wet venting is limited to ______ fixtures4
Maximum length of a tailpiece0.6 m
What is an underground drain pipe that receives only sub-surface or seepage water and convey it to a sump for disposal by gravity flow or by lift pump?subsoil drain
Connects directly with an individual trap underneath or behind the fixtureBackvent Pipe
What can be drained through an airbreak?air washer
The size of a vent pipe is determined by __________.FU and length
In getting the roof area for the computation of rainwater piping size, for two walls opposite of differing heights, add _______ of wall area above top of lower wall to the roof area.50%
Elastomeric gasketed and rubber-ring joints shall comply with _________ installation standardIAPMO
The minimum inlet and outlet size for sand interceptor76 mm
What is the maximum length allowed for a vent stack serving 48 DFU?55
For accessible toilets, signs on walls and doors should be located at a maximum height of _______.1.60 m
What is the horizontal distance required of a vent pipe from any openable window, door opening, air intake, or vent shaft?3 m
The maximum trap loading of a pipe size 76 mm6
Vertical vent pipes installed in a roof used for other purposes shall extend a minimum of ________ above such roof.2.1 m
If a septic tank can have an effective capacity of 4000 L, how much does the secondary compartment hold?1,333 L
The principal artery of the venting system to which vent branches are connected.Main Vent
The bottom of the water pipe, at all points shall be at least _________ above the top of the sewer or drain line.0.3 m
What is the minimum distance from disposal field to another disposal field?1.2 m
What is the sewage that turns dark and smell unpleasantly due to anaerobic decomposition?septic
Determine the size of horizontal rainwater piping with a slope of 2% for a 350 sqm roof in an area where the the rainfall is 102 mm/hr.127 mm
When the first compartment exceeds 3.7 m in length, an additional ________ shall be provided.manhole
Rainwater piping located within a medium height building basement area shall be of Galvanized Iron _______.Schedule 30
What will be the size of 0.5% sloped circular bottom gutter serving a roof area of 180 sqm, and the rainfall intensity around the area is 76 mm/hr?178 mm
What downspout size would you specify for an 800 sqm roof with a rainfall intensity around the area of 152.4 mm/hr?152 mm
Minimum distance of a 32 mm trap arm diameter to a vent64 mm
The minimum depth of the sand interceptor under the invert of the outlet pipe is ________.610 mm
The side walls of a Septic Tank shall be at least __________ above the liquid depth.9”
All condensers and sumps shall be properly trapped at the outlet with a deep seal trap extending to within _________ of the bottom of the tank.6”
A 203 mm diameter and larger sewer may have a slope of _________.0.5%
In a granule test of a water closet, the initial flush of three different flushes must result in no more than ___________ on average remaining in the bowl.125
What is the minimum condensate pipe diameter of a cooling equipment with capacity through 125 ToR?38 mm
A water that stands in or passes through the groundGround Water
Jointing method for soft copper water tubingFlared Joint
What is required when a soil or waste stack extends 10 or more stories?Parallel Vent Stack
Minimum water seal of a grease trap51 mm
Septic tanks should be cleaned when scum or sludge occupies ________ of the tank volume.1/3
Every abandoned building sewer shall be plugged or capped within __________ of the property line.1.5 m
Water closets that are made to accommodate overweight and obese peopleBariatic Water Closet
_________ are recommended for oil handling piping works.Neoprene Gaskets
Horizontal distance of the trap arm with a diameter of 38 mm1.07 m
What is the gauge pressure to be maintained for air tests as substitute for water test in water pipings?344.5 kPa
What is the estimated sewage flow rate of bowling alleys with snack bar only?283.9 LpD per lane
What is the storage factor for self-service auto washers?1.5
Minimum dimension of a sand interceptor's inlet opening0.2 sq.m.
A group vent pipe that connects to the vent stackCircuit Vent
Prohibited vent pipe material below groundGalvanized Wrought Iron
Minimum spacing between trenches or leaching beds1.20 m
Which among the choices is a prohibited trap?Crown trap
Normally in Manila, the rainfall intensity used is _____.102 mm
Maximum number of slip joint fitting that may be used on the outlet side of a trap1
Wet venting is limited to ______ fixtures4
Maximum length of a tailpiece0.6 m
What is an underground drain pipe that receives only sub-surface or seepage water and convey it to a sump for disposal by gravity flow or by lift pump?subsoil drain
Connects directly with an individual trap underneath or behind the fixtureBackvent Pipe
What can be drained through an airbreak?air washer
The size of a vent pipe is determined by __________.FU and length
In getting the roof area for the computation of rainwater piping size, for two walls opposite of differing heights, add _______ of wall area above top of lower wall to the roof area.50%
Elastomeric gasketed and rubber-ring joints shall comply with _________ installation standardIAPMO
The minimum inlet and outlet size for sand interceptor76 mm
What is the maximum length allowed for a vent stack serving 48 DFU?55
For accessible toilets, signs on walls and doors should be located at a maximum height of _______.1.60 m
What is the horizontal distance required of a vent pipe from any openable window, door opening, air intake, or vent shaft?3 m
The maximum trap loading of a pipe size 76 mm6
Vertical vent pipes installed in a roof used for other purposes shall extend a minimum of ________ above such roof.2.1 m
If a septic tank can have an effective capacity of 4000 L, how much does the secondary compartment hold?1,333 L
The principal artery of the venting system to which vent branches are connected.Main Vent
The bottom of the water pipe, at all points shall be at least _________ above the top of the sewer or drain line.0.3 m
What is the minimum distance from disposal field to another disposal field?1.2 m
What is the sewage that turns dark and smell unpleasantly due to anaerobic decomposition?septic
Determine the size of horizontal rainwater piping with a slope of 2% for a 350 sqm roof in an area where the the rainfall is 102 mm/hr.127 mm
When the first compartment exceeds 3.7 m in length, an additional ________ shall be provided.manhole
Rainwater piping located within a medium height building basement area shall be of Galvanized Iron _______.Schedule 30
What will be the size of 0.5% sloped circular bottom gutter serving a roof area of 180 sqm, and the rainfall intensity around the area is 76 mm/hr?178 mm
What downspout size would you specify for an 800 sqm roof with a rainfall intensity around the area of 152.4 mm/hr?152 mm
Minimum distance of a 32 mm trap arm diameter to a vent64 mm
The minimum depth of the sand interceptor under the invert of the outlet pipe is ________.610 mm
The side walls of a Septic Tank shall be at least __________ above the liquid depth.9”
All condensers and sumps shall be properly trapped at the outlet with a deep seal trap extending to within _________ of the bottom of the tank.6”
A 203 mm diameter and larger sewer may have a slope of _________.0.5%
In a granule test of a water closet, the initial flush of three different flushes must result in no more than ___________ on average remaining in the bowl.125
What is the minimum condensate pipe diameter of a cooling equipment with capacity through 125 ToR?38 mm
A water that stands in or passes through the groundGround Water
Jointing method for soft copper water tubingFlared Joint
What is required when a soil or waste stack extends 10 or more stories?Parallel Vent Stack
Minimum water seal of a grease trap51 mm
Septic tanks should be cleaned when scum or sludge occupies ________ of the tank volume.1/3
Every abandoned building sewer shall be plugged or capped within __________ of the property line.1.5 m
Water closets that are made to accommodate overweight and obese peopleBariatic Water Closet
_________ are recommended for oil handling piping works.Neoprene Gaskets
Horizontal distance of the trap arm with a diameter of 38 mm1.07 m
What is the gauge pressure to be maintained for air tests as substitute for water test in water pipings?344.5 kPa