問題一覧
1
C. Engine generators, external power then APU
2
A. AC
3
A. 2 engine generators and 1 APU generator
4
A. three phase 115/200V 400Hz
5
A. three phase 115/200 V 400 Hz
6
A. BLUE
7
A. three phase 115/200V 400Hz
8
A. AC BUS
9
A. via TR
10
A. Other engine generator or APU GEN
11
B. False, The RAT powers the blue hydraulic system, which drives the Emergency generator by means of a hydraulic motor
12
B. The RAT is deployed, and the aircraft speed is greater than 100kt
13
B. The battery charge limiter is in fault
14
C. You have to verify that both batteries are off
15
B. By pushing the EXT PWR pushbutton, thus disconnecting the external power
16
True
17
C. Never disconnect an IDG unless the engine is running, nor push the IDG disconnect pushbutton for more than 3 seconds
18
B. Green circuit breakers are monitored by the ECAM
19
A. The EMER GEN is not supplying electrical power when AC BUS 1 and AC BUS 2 are not powered
20
B. Once, if authorized by the procedures
21
B. Wait 5 sec before pushing it back
22
C. No, it is not possible
23
A. at or below 25.5V
24
A. ACP 1 and 2, VHF 1, HF1, RMP 1, VOR 1, and MMR 1
25
B. The green AVAIL light will illuminate on the EXT PWR push button
26
A. External power
LIMITATION
LIMITATION
Popovich · 30問 · 2年前LIMITATION
LIMITATION
30問 • 2年前ВК РУз
ВК РУз
Popovich · 37問 · 1ヶ月前ВК РУз
ВК РУз
37問 • 1ヶ月前A-320 Chapter № 1. Aircraft general
A-320 Chapter № 1. Aircraft general
Popovich · 7問 · 1ヶ月前A-320 Chapter № 1. Aircraft general
A-320 Chapter № 1. Aircraft general
7問 • 1ヶ月前A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation
A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation
Popovich · 31問 · 1ヶ月前A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation
A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation
31問 • 1ヶ月前A-320 Chapter № 3. Autoflight
A-320 Chapter № 3. Autoflight
Popovich · 40問 · 1ヶ月前A-320 Chapter № 3. Autoflight
A-320 Chapter № 3. Autoflight
40問 • 1ヶ月前A-320 Chapter № 4. Communication
A-320 Chapter № 4. Communication
Popovich · 18問 · 1ヶ月前A-320 Chapter № 4. Communication
A-320 Chapter № 4. Communication
18問 • 1ヶ月前A-320 Chapter № 6. Equipment
A-320 Chapter № 6. Equipment
Popovich · 7問 · 1ヶ月前A-320 Chapter № 6. Equipment
A-320 Chapter № 6. Equipment
7問 • 1ヶ月前A-320 Chapter № 7. Fire protection
A-320 Chapter № 7. Fire protection
Popovich · 20問 · 1ヶ月前A-320 Chapter № 7. Fire protection
A-320 Chapter № 7. Fire protection
20問 • 1ヶ月前A-320 Chapter № 8. Flight Controls
A-320 Chapter № 8. Flight Controls
Popovich · 42問 · 1ヶ月前A-320 Chapter № 8. Flight Controls
A-320 Chapter № 8. Flight Controls
42問 • 1ヶ月前A-320 Chapter № 9. Fuel
A-320 Chapter № 9. Fuel
Popovich · 21問 · 1ヶ月前A-320 Chapter № 9. Fuel
A-320 Chapter № 9. Fuel
21問 • 1ヶ月前A-320 Chapter № 10. Hydraulic
A-320 Chapter № 10. Hydraulic
Popovich · 17問 · 1ヶ月前A-320 Chapter № 10. Hydraulic
A-320 Chapter № 10. Hydraulic
17問 • 1ヶ月前A-320 Chapter № 11. Ice and Rain
A-320 Chapter № 11. Ice and Rain
Popovich · 17問 · 1ヶ月前A-320 Chapter № 11. Ice and Rain
A-320 Chapter № 11. Ice and Rain
17問 • 1ヶ月前A-320 Chapter № 12. Indicating / Recording
A-320 Chapter № 12. Indicating / Recording
Popovich · 38問 · 1ヶ月前A-320 Chapter № 12. Indicating / Recording
A-320 Chapter № 12. Indicating / Recording
38問 • 1ヶ月前A-320 Chapter № 13. Landing gear
A-320 Chapter № 13. Landing gear
Popovich · 37問 · 1ヶ月前A-320 Chapter № 13. Landing gear
A-320 Chapter № 13. Landing gear
37問 • 1ヶ月前A-320 Chapter № 14. Lights
A-320 Chapter № 14. Lights
Popovich · 11問 · 1ヶ月前A-320 Chapter № 14. Lights
A-320 Chapter № 14. Lights
11問 • 1ヶ月前A-320 Chapter № 15. Navigation and Surveillance
A-320 Chapter № 15. Navigation and Surveillance
Popovich · 30問 · 1ヶ月前A-320 Chapter № 15. Navigation and Surveillance
A-320 Chapter № 15. Navigation and Surveillance
30問 • 1ヶ月前A-320 Chapter № 16. Oxygen
A-320 Chapter № 16. Oxygen
Popovich · 15問 · 1ヶ月前A-320 Chapter № 16. Oxygen
A-320 Chapter № 16. Oxygen
15問 • 1ヶ月前A-320 Chapter № 17. Pneumatic
A-320 Chapter № 17. Pneumatic
Popovich · 12問 · 1ヶ月前A-320 Chapter № 17. Pneumatic
A-320 Chapter № 17. Pneumatic
12問 • 1ヶ月前A-320 Chapter № 18. Water / Waste
A-320 Chapter № 18. Water / Waste
Popovich · 7問 · 1ヶ月前A-320 Chapter № 18. Water / Waste
A-320 Chapter № 18. Water / Waste
7問 • 1ヶ月前問題一覧
1
C. Engine generators, external power then APU
2
A. AC
3
A. 2 engine generators and 1 APU generator
4
A. three phase 115/200V 400Hz
5
A. three phase 115/200 V 400 Hz
6
A. BLUE
7
A. three phase 115/200V 400Hz
8
A. AC BUS
9
A. via TR
10
A. Other engine generator or APU GEN
11
B. False, The RAT powers the blue hydraulic system, which drives the Emergency generator by means of a hydraulic motor
12
B. The RAT is deployed, and the aircraft speed is greater than 100kt
13
B. The battery charge limiter is in fault
14
C. You have to verify that both batteries are off
15
B. By pushing the EXT PWR pushbutton, thus disconnecting the external power
16
True
17
C. Never disconnect an IDG unless the engine is running, nor push the IDG disconnect pushbutton for more than 3 seconds
18
B. Green circuit breakers are monitored by the ECAM
19
A. The EMER GEN is not supplying electrical power when AC BUS 1 and AC BUS 2 are not powered
20
B. Once, if authorized by the procedures
21
B. Wait 5 sec before pushing it back
22
C. No, it is not possible
23
A. at or below 25.5V
24
A. ACP 1 and 2, VHF 1, HF1, RMP 1, VOR 1, and MMR 1
25
B. The green AVAIL light will illuminate on the EXT PWR push button
26
A. External power