ログイン

A-320 Chapter № 7. Fire protection
20問 • 1ヶ月前
  • Popovich
  • 通報

    問題一覧

  • 1

    7.1. Avionics Compartment does not contain an installed fire extinguishing system:

    True

  • 2

    7.2. The aircraft has dual fire detector loops to ensure that a fault in one fire loop will not affect fire detection capabilities.

    True

  • 3

    7.3. If there is an APU fire in flight the APU:

    B. Must be shut down manually and the agent manually discharged

  • 4

    7.4. Fire protection for the cargo compartments includes:

    A. Two fire bottles supplying multiple nozzles (nozzle quantity depends on the option)

  • 5

    7.5. The engine extinguisher squibs are armed when:

    C. The engine fire switch is released out

  • 6

    7.6. When the APU FIRE SWITCH is released out:

    C. The APU bleed and crossbleed valves are closed, the APU generator is deactivated

  • 7

    7.7. DISCH light on either the engine or APU fire agent switches indicates:

    B. The extinguisher bottle has been discharged

  • 8

    7.8. When the aircraft is on the ground and the APU is started on battery power only, is fire protection available?

    A. Yes, the APU will initiate an auto shutdown and discharge the extinguishing agent

  • 9

    7.9. How many fire extinguishing bottles are available for fighting an APU fire?

    A. One

  • 10

    7.10. During APU fire test you see these indications. Is it correct

    A. Yes, it is correct for APU fire test with BATT ON only

  • 11

    7.11. Can the APU FIRE test be performed using battery power only?

    Yes

  • 12

    7.12. Which of the following have automatic fire extinguishing systems

    A. APU and lavatory waste bins

  • 13

    7.13. The A320 FWD Cargo Compartment smoke detection system consists of:

    B. Two smoke detectors and a two-channel smoke detection control unit

  • 14

    7.14. The A321 AFT Cargo Compartment smoke detection system consists of:

    A. Six smoke detectors and a two-channel smoke detection control unit

  • 15

    7.15. What is it indicated by a missing red APU thermal plug during an exterior preflight?

    B. An APU fire agent thermal discharge has occurred

  • 16

    7.16. If the lavatory smoke detector detects smoke:

    C. Warnings will be generated in the cockpit and in the cabin

  • 17

    7.17. Are there any warnings to alert ground personnel when there is a fire in the APU compartment?

    C. Yes, the external fire warning horn will sound and the APU red fire light will illuminate on the external power panel

  • 18

    7.18. How many halon fire extinguishing cylinders are there per engine?

    A. Each engine has two fire extinguishers

  • 19

    7.19. If AFT or FWD Cargo Compartment smoke detectors detect smoke:

    C. The crew must depress the appropriate agent DISCH switch

  • 20

    7.20. The APU is provided with automatic fire extinguishing:

    A. On the ground only

  • LIMITATION

    LIMITATION

    Popovich · 30問 · 2年前

    LIMITATION

    LIMITATION

    30問 • 2年前
    Popovich

    ВК РУз

    ВК РУз

    Popovich · 37問 · 1ヶ月前

    ВК РУз

    ВК РУз

    37問 • 1ヶ月前
    Popovich

    A-320 Chapter № 1. Aircraft general

    A-320 Chapter № 1. Aircraft general

    Popovich · 7問 · 1ヶ月前

    A-320 Chapter № 1. Aircraft general

    A-320 Chapter № 1. Aircraft general

    7問 • 1ヶ月前
    Popovich

    A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation

    A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation

    Popovich · 31問 · 1ヶ月前

    A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation

    A-320 Chapter № 2. Air Conditioning / Pressurization / Ventilation

    31問 • 1ヶ月前
    Popovich

    A-320 Chapter № 3. Autoflight

    A-320 Chapter № 3. Autoflight

    Popovich · 40問 · 1ヶ月前

    A-320 Chapter № 3. Autoflight

    A-320 Chapter № 3. Autoflight

    40問 • 1ヶ月前
    Popovich

    A-320 Chapter № 4. Communication

    A-320 Chapter № 4. Communication

    Popovich · 18問 · 1ヶ月前

    A-320 Chapter № 4. Communication

    A-320 Chapter № 4. Communication

    18問 • 1ヶ月前
    Popovich

    A-320 Chapter № 5. Electrical

    A-320 Chapter № 5. Electrical

    Popovich · 26問 · 1ヶ月前

    A-320 Chapter № 5. Electrical

    A-320 Chapter № 5. Electrical

    26問 • 1ヶ月前
    Popovich

    A-320 Chapter № 6. Equipment

    A-320 Chapter № 6. Equipment

    Popovich · 7問 · 1ヶ月前

    A-320 Chapter № 6. Equipment

    A-320 Chapter № 6. Equipment

    7問 • 1ヶ月前
    Popovich

    A-320 Chapter № 8. Flight Controls

    A-320 Chapter № 8. Flight Controls

    Popovich · 42問 · 1ヶ月前

    A-320 Chapter № 8. Flight Controls

    A-320 Chapter № 8. Flight Controls

    42問 • 1ヶ月前
    Popovich

    A-320 Chapter № 9. Fuel

    A-320 Chapter № 9. Fuel

    Popovich · 21問 · 1ヶ月前

    A-320 Chapter № 9. Fuel

    A-320 Chapter № 9. Fuel

    21問 • 1ヶ月前
    Popovich

    A-320 Chapter № 10. Hydraulic

    A-320 Chapter № 10. Hydraulic

    Popovich · 17問 · 1ヶ月前

    A-320 Chapter № 10. Hydraulic

    A-320 Chapter № 10. Hydraulic

    17問 • 1ヶ月前
    Popovich

    A-320 Chapter № 11. Ice and Rain

    A-320 Chapter № 11. Ice and Rain

    Popovich · 17問 · 1ヶ月前

    A-320 Chapter № 11. Ice and Rain

    A-320 Chapter № 11. Ice and Rain

    17問 • 1ヶ月前
    Popovich

    A-320 Chapter № 12. Indicating / Recording

    A-320 Chapter № 12. Indicating / Recording

    Popovich · 38問 · 1ヶ月前

    A-320 Chapter № 12. Indicating / Recording

    A-320 Chapter № 12. Indicating / Recording

    38問 • 1ヶ月前
    Popovich

    A-320 Chapter № 13. Landing gear

    A-320 Chapter № 13. Landing gear

    Popovich · 37問 · 1ヶ月前

    A-320 Chapter № 13. Landing gear

    A-320 Chapter № 13. Landing gear

    37問 • 1ヶ月前
    Popovich

    A-320 Chapter № 14. Lights

    A-320 Chapter № 14. Lights

    Popovich · 11問 · 1ヶ月前

    A-320 Chapter № 14. Lights

    A-320 Chapter № 14. Lights

    11問 • 1ヶ月前
    Popovich

    A-320 Chapter № 15. Navigation and Surveillance

    A-320 Chapter № 15. Navigation and Surveillance

    Popovich · 30問 · 1ヶ月前

    A-320 Chapter № 15. Navigation and Surveillance

    A-320 Chapter № 15. Navigation and Surveillance

    30問 • 1ヶ月前
    Popovich

    A-320 Chapter № 16. Oxygen

    A-320 Chapter № 16. Oxygen

    Popovich · 15問 · 1ヶ月前

    A-320 Chapter № 16. Oxygen

    A-320 Chapter № 16. Oxygen

    15問 • 1ヶ月前
    Popovich

    A-320 Chapter № 17. Pneumatic

    A-320 Chapter № 17. Pneumatic

    Popovich · 12問 · 1ヶ月前

    A-320 Chapter № 17. Pneumatic

    A-320 Chapter № 17. Pneumatic

    12問 • 1ヶ月前
    Popovich

    A-320 Chapter № 18. Water / Waste

    A-320 Chapter № 18. Water / Waste

    Popovich · 7問 · 1ヶ月前

    A-320 Chapter № 18. Water / Waste

    A-320 Chapter № 18. Water / Waste

    7問 • 1ヶ月前
    Popovich

    問題一覧

  • 1

    7.1. Avionics Compartment does not contain an installed fire extinguishing system:

    True

  • 2

    7.2. The aircraft has dual fire detector loops to ensure that a fault in one fire loop will not affect fire detection capabilities.

    True

  • 3

    7.3. If there is an APU fire in flight the APU:

    B. Must be shut down manually and the agent manually discharged

  • 4

    7.4. Fire protection for the cargo compartments includes:

    A. Two fire bottles supplying multiple nozzles (nozzle quantity depends on the option)

  • 5

    7.5. The engine extinguisher squibs are armed when:

    C. The engine fire switch is released out

  • 6

    7.6. When the APU FIRE SWITCH is released out:

    C. The APU bleed and crossbleed valves are closed, the APU generator is deactivated

  • 7

    7.7. DISCH light on either the engine or APU fire agent switches indicates:

    B. The extinguisher bottle has been discharged

  • 8

    7.8. When the aircraft is on the ground and the APU is started on battery power only, is fire protection available?

    A. Yes, the APU will initiate an auto shutdown and discharge the extinguishing agent

  • 9

    7.9. How many fire extinguishing bottles are available for fighting an APU fire?

    A. One

  • 10

    7.10. During APU fire test you see these indications. Is it correct

    A. Yes, it is correct for APU fire test with BATT ON only

  • 11

    7.11. Can the APU FIRE test be performed using battery power only?

    Yes

  • 12

    7.12. Which of the following have automatic fire extinguishing systems

    A. APU and lavatory waste bins

  • 13

    7.13. The A320 FWD Cargo Compartment smoke detection system consists of:

    B. Two smoke detectors and a two-channel smoke detection control unit

  • 14

    7.14. The A321 AFT Cargo Compartment smoke detection system consists of:

    A. Six smoke detectors and a two-channel smoke detection control unit

  • 15

    7.15. What is it indicated by a missing red APU thermal plug during an exterior preflight?

    B. An APU fire agent thermal discharge has occurred

  • 16

    7.16. If the lavatory smoke detector detects smoke:

    C. Warnings will be generated in the cockpit and in the cabin

  • 17

    7.17. Are there any warnings to alert ground personnel when there is a fire in the APU compartment?

    C. Yes, the external fire warning horn will sound and the APU red fire light will illuminate on the external power panel

  • 18

    7.18. How many halon fire extinguishing cylinders are there per engine?

    A. Each engine has two fire extinguishers

  • 19

    7.19. If AFT or FWD Cargo Compartment smoke detectors detect smoke:

    C. The crew must depress the appropriate agent DISCH switch

  • 20

    7.20. The APU is provided with automatic fire extinguishing:

    A. On the ground only