  • 1

    Micro Ohmeter

    used to test contact resistance in substation circuit breakers & switches

  • 2

    Service Conductor tester

    Placed in meter sockets & apply load to service

  • 3

    TDR

    Time Domain Reflectometer

  • 4

    Phasing meter

    High-Voltage voltmeter

  • 5

    Voltage Detector

    Used for testing a high-voltage line to determine if it’s energized or not

  • 6

    If Voltage Dectector doesn’t sound alarm, there is no voltage present or…

    the meter is malfunctioning

  • 7

    Surge Generator is also known as

    The Thumper

  • 8

    The digiphone pinpointer is w/

    Surge Generator

  • 9

    Ammeter measures

    Current

  • 10

    How does the ammeter work

    by measuring the strength of the magnetic field around the wire

  • 11

    DC hi-pot

    test cables for faults

  • 12

    How does the DC hi-pot react to faulted cables

    the needle rises and holds

  • 13

    ARS

    Arc Reflection System

  • 14

    What’s and advantage of using the ARS instead of the DC hi-pot

    the ARS can detect faults through transformers

  • 15

    Rotation Meter also known as

    “Phase Sequence Indicator

  • 16

    The Phase sequence Indicator (rotation meter) is used

    before work begins and after work is finished

  • 17

    Insulation Power Factor testers

    Detect level of insulation breakdown in substation apparatus

  • 18

    Insulation Power Factors can only be used on De-energized lines

    false

  • 19

    Cable locators work by detecting signal (along the length of the cable) placed there by a transmitter

    True

  • 20

    Conductive and Inductive tracing is related to..

    Cable Locators

  • 21

    testing a line for the presences of voltage before installing protective grounds is a requirement by OSHA

    True

  • 22

    Phasing is necessary when

    work is being preformed on a junction of the main feeder circuit

  • 23

    Secondary fault locating is usually preformed on..

    overhead services

  • 24

    Customer contact is most common when using

    Low-Voltage test equipment

  • 25

    Which two functions of the digital multimeter are most commonly used by line workers

    AC Voltage & Contuitity

  • 26

    Customer calls with a problem; however, every time service is check, everything is ok. The problem has not gone away and the customer has called several times. What do you next?

    install recording voltmeter and recording ammeter

  • Electrical Systems

    Electrical Systems

    Maxwell Nemir · 25問 · 1年前

    Electrical Systems

    Electrical Systems

    25問 • 1年前
    Maxwell Nemir

    Applied Mathematics

    Applied Mathematics

    Maxwell Nemir · 25問 · 1年前

    Applied Mathematics

    Applied Mathematics

    25問 • 1年前
    Maxwell Nemir

    Introduction to Substations

    Introduction to Substations

    Maxwell Nemir · 31問 · 1年前

    Introduction to Substations

    Introduction to Substations

    31問 • 1年前
    Maxwell Nemir

    Into to power delivery

    Into to power delivery

    Maxwell Nemir · 23問 · 1年前

    Into to power delivery

    Into to power delivery

    23問 • 1年前
    Maxwell Nemir

    Electronics

    Electronics

    Maxwell Nemir · 24問 · 1年前

    Electronics

    Electronics

    24問 • 1年前
    Maxwell Nemir

    AC Fundmentals

    AC Fundmentals

    Maxwell Nemir · 25問 · 1年前

    AC Fundmentals

    AC Fundmentals

    25問 • 1年前
    Maxwell Nemir

    Substation Safety 2

    Substation Safety 2

    Maxwell Nemir · 25問 · 1年前

    Substation Safety 2

    Substation Safety 2

    25問 • 1年前
    Maxwell Nemir

    Rigging

    Rigging

    Maxwell Nemir · 11問 · 1年前

    Rigging

    Rigging

    11問 • 1年前
    Maxwell Nemir

    Disconnects and Switches

    Disconnects and Switches

    Maxwell Nemir · 25問 · 1年前

    Disconnects and Switches

    Disconnects and Switches

    25問 • 1年前
    Maxwell Nemir

    OSHA 2

    OSHA 2

    Maxwell Nemir · 25問 · 1年前

    OSHA 2

    OSHA 2

    25問 • 1年前
    Maxwell Nemir

    White Hat Test

    White Hat Test

    Maxwell Nemir · 27問 · 1年前

    White Hat Test

    White Hat Test

    27問 • 1年前
    Maxwell Nemir

    White hat test #2

    White hat test #2

    Maxwell Nemir · 18問 · 1年前

    White hat test #2

    White hat test #2

    18問 • 1年前
    Maxwell Nemir

    Into to power delivery

    Into to power delivery

    Maxwell Nemir · 23問 · 7ヶ月前

    Into to power delivery

    Into to power delivery

    23問 • 7ヶ月前
    Maxwell Nemir

    問題一覧

  • 1

    Micro Ohmeter

    used to test contact resistance in substation circuit breakers & switches

  • 2

    Service Conductor tester

    Placed in meter sockets & apply load to service

  • 3

    TDR

    Time Domain Reflectometer

  • 4

    Phasing meter

    High-Voltage voltmeter

  • 5

    Voltage Detector

    Used for testing a high-voltage line to determine if it’s energized or not

  • 6

    If Voltage Dectector doesn’t sound alarm, there is no voltage present or…

    the meter is malfunctioning

  • 7

    Surge Generator is also known as

    The Thumper

  • 8

    The digiphone pinpointer is w/

    Surge Generator

  • 9

    Ammeter measures

    Current

  • 10

    How does the ammeter work

    by measuring the strength of the magnetic field around the wire

  • 11

    DC hi-pot

    test cables for faults

  • 12

    How does the DC hi-pot react to faulted cables

    the needle rises and holds

  • 13

    ARS

    Arc Reflection System

  • 14

    What’s and advantage of using the ARS instead of the DC hi-pot

    the ARS can detect faults through transformers

  • 15

    Rotation Meter also known as

    “Phase Sequence Indicator

  • 16

    The Phase sequence Indicator (rotation meter) is used

    before work begins and after work is finished

  • 17

    Insulation Power Factor testers

    Detect level of insulation breakdown in substation apparatus

  • 18

    Insulation Power Factors can only be used on De-energized lines

    false

  • 19

    Cable locators work by detecting signal (along the length of the cable) placed there by a transmitter

    True

  • 20

    Conductive and Inductive tracing is related to..

    Cable Locators

  • 21

    testing a line for the presences of voltage before installing protective grounds is a requirement by OSHA

    True

  • 22

    Phasing is necessary when

    work is being preformed on a junction of the main feeder circuit

  • 23

    Secondary fault locating is usually preformed on..

    overhead services

  • 24

    Customer contact is most common when using

    Low-Voltage test equipment

  • 25

    Which two functions of the digital multimeter are most commonly used by line workers

    AC Voltage & Contuitity

  • 26

    Customer calls with a problem; however, every time service is check, everything is ok. The problem has not gone away and the customer has called several times. What do you next?

    install recording voltmeter and recording ammeter