ログイン

Noor 3
26問 • 5ヶ月前
  • ユーザ名非公開
  • 通報

    問題一覧

  • 1

    1. Without added oxygen the time of useful consciousness at 30 000 ft is approximately:

    c. one to two minutes

  • 2

    2. Without added oxygen the time of useful consciousness at 40 000 ft is approximately:

    a. twenty seconds

  • 3

    3. The maximum altitude without oxygen at which flying efficiency is not seriously impaired is:

    a. 10 000 ft

  • 4

    4. In a pressure demand oxygen system:

    a. each member of the crew has a regulator

  • 5

    5. In a continuous flow oxygen system, oxygen is supplied:

    a. only when the mask is plugged into the socket connection

  • 6

    6 In a diluter demand system, selection of emergency on this regulator will result in:

    d. 100% oxygen continuous flow at positive pressure

  • 7

    7. If the aircraft suffers a decompression passenger oxygen masks:

    b. automatically drop to a half-hung (ready position)

  • 8

    8. Oxygen cylinders are normally charged to:

    c. 1800 psi

  • 9

    9. Rate of flow of oxygen is given in:

    a. litres/minute

  • 10

    10. The colour of American and European oxygen cylinders is:

    c. green

  • 11

    11. Dangerous pressure rise in oxygen cylinders:

    c. is relieved by a bursting disc

  • 12

    12. To leak test an oxygen system use:

    c. acid free soap and distilled water

  • 13

    13. Lubrication of an oxygen component thread is by:

    d. graphite

  • 14

    14. Satisfactory operation of the oxygen system is indicated by:

    a. flow indicators

  • 15

    15. If the pressurization system fails and the cabin starts to climb, then at 14 000 ft oxygen will be available to the passengers by:

    d. masks automatically ejected to a half-hung position

  • 16

    16. When air is pressurized the % of oxygen:

    c. remains the same

  • 17

    17. In an emergency chemically produced oxygen is supplied for a given period by:

    a. sodium chlorate, iron power, an electrical firing system and a filter

  • 18

    18. Passenger oxygen masks will present:

    d. if selected manually / electrically / barometrically

  • 19

    19. The charged pressure of a portable oxygen cylinder is normally:

    c. 1800 psi

  • 20

    20. With the control knob set to high, a 120 litre portable bottle will provide oxygen for a period of:

    b. 30 mins

  • 21

    21. At what altitude will the diluter-demand oxygen regulator provide 100% pure oxygen:

    d. 34 000 ft

  • 22

    22. A flow indicator fitted to an oxygen regulator indicates:

    b. that oxygen is flowing through the regulator

  • 23

    23. What is the approximate time of useful consciousness when hypoxia develops at the specified altitudes? 20 000 ft 30 000 ft

    c. 30 min 90-60 secs

  • 24

    24. What is the effect on cabin temperature of a rapid de-compression at 30 000 ft?

    a. Sudden and extreme drop

  • 25

    25. Susceptibility to hypoxia is increased by:

    c. smoking

  • 26

    26. What is the approximate cabin altitude above which you must breath 100% oxygen if you are to maintain an alveolar partial pressure equal to that at sea level?

    c. 34 000 ft

  • Noor 1

    Noor 1

    ユーザ名非公開 · 25問 · 5ヶ月前

    Noor 1

    Noor 1

    25問 • 5ヶ月前
    ユーザ名非公開

    Noor 2

    Noor 2

    ユーザ名非公開 · 21問 · 5ヶ月前

    Noor 2

    Noor 2

    21問 • 5ヶ月前
    ユーザ名非公開

    Noor 4

    Noor 4

    ユーザ名非公開 · 10問 · 5ヶ月前

    Noor 4

    Noor 4

    10問 • 5ヶ月前
    ユーザ名非公開

    Noor 5

    Noor 5

    ユーザ名非公開 · 11問 · 5ヶ月前

    Noor 5

    Noor 5

    11問 • 5ヶ月前
    ユーザ名非公開

    Noor 6

    Noor 6

    ユーザ名非公開 · 13問 · 5ヶ月前

    Noor 6

    Noor 6

    13問 • 5ヶ月前
    ユーザ名非公開

    問題一覧

  • 1

    1. Without added oxygen the time of useful consciousness at 30 000 ft is approximately:

    c. one to two minutes

  • 2

    2. Without added oxygen the time of useful consciousness at 40 000 ft is approximately:

    a. twenty seconds

  • 3

    3. The maximum altitude without oxygen at which flying efficiency is not seriously impaired is:

    a. 10 000 ft

  • 4

    4. In a pressure demand oxygen system:

    a. each member of the crew has a regulator

  • 5

    5. In a continuous flow oxygen system, oxygen is supplied:

    a. only when the mask is plugged into the socket connection

  • 6

    6 In a diluter demand system, selection of emergency on this regulator will result in:

    d. 100% oxygen continuous flow at positive pressure

  • 7

    7. If the aircraft suffers a decompression passenger oxygen masks:

    b. automatically drop to a half-hung (ready position)

  • 8

    8. Oxygen cylinders are normally charged to:

    c. 1800 psi

  • 9

    9. Rate of flow of oxygen is given in:

    a. litres/minute

  • 10

    10. The colour of American and European oxygen cylinders is:

    c. green

  • 11

    11. Dangerous pressure rise in oxygen cylinders:

    c. is relieved by a bursting disc

  • 12

    12. To leak test an oxygen system use:

    c. acid free soap and distilled water

  • 13

    13. Lubrication of an oxygen component thread is by:

    d. graphite

  • 14

    14. Satisfactory operation of the oxygen system is indicated by:

    a. flow indicators

  • 15

    15. If the pressurization system fails and the cabin starts to climb, then at 14 000 ft oxygen will be available to the passengers by:

    d. masks automatically ejected to a half-hung position

  • 16

    16. When air is pressurized the % of oxygen:

    c. remains the same

  • 17

    17. In an emergency chemically produced oxygen is supplied for a given period by:

    a. sodium chlorate, iron power, an electrical firing system and a filter

  • 18

    18. Passenger oxygen masks will present:

    d. if selected manually / electrically / barometrically

  • 19

    19. The charged pressure of a portable oxygen cylinder is normally:

    c. 1800 psi

  • 20

    20. With the control knob set to high, a 120 litre portable bottle will provide oxygen for a period of:

    b. 30 mins

  • 21

    21. At what altitude will the diluter-demand oxygen regulator provide 100% pure oxygen:

    d. 34 000 ft

  • 22

    22. A flow indicator fitted to an oxygen regulator indicates:

    b. that oxygen is flowing through the regulator

  • 23

    23. What is the approximate time of useful consciousness when hypoxia develops at the specified altitudes? 20 000 ft 30 000 ft

    c. 30 min 90-60 secs

  • 24

    24. What is the effect on cabin temperature of a rapid de-compression at 30 000 ft?

    a. Sudden and extreme drop

  • 25

    25. Susceptibility to hypoxia is increased by:

    c. smoking

  • 26

    26. What is the approximate cabin altitude above which you must breath 100% oxygen if you are to maintain an alveolar partial pressure equal to that at sea level?

    c. 34 000 ft