ログイン

rules ac

rules ac
11問 • 1年前
  • john collins
  • 通報

    問題一覧

  • 1

    Minimum distance from ole

    2.75m 9ft

  • 2

    What must you do before asking for switch off if obstruction on another line

    protect obstruction

  • 3

    Rescuing a person within 2.75m 9ft of ole, what distance must they be away from ole

    600mm 2ft

  • 4

    Actions if loss of line light, ADD operation, tripping, damage to ole

    drop,stop,box

  • 5

    Line light goes out, can continue if

    ADD available but not operated, no unusual movement or noises from ole, can reset at first attempt, regain power

  • 6

    Examining ole max speed, when would you need competent person

    20

  • 7

    What are checking when looking at ole

    obstruction not more than 150mm 6in below contact wire, no more than 2 consecutive droppers come off, more than 3 ole structures away from tunnel or overbridge, nothing else obvious

  • 8

    Coasting with pantograph down, max speed

    20

  • 9

    What must you do if told about defective APC track inductor

    shut off power before neutral section

  • 10

    What 4 things must you be sure of before rescuing a person

    alive and can be reached from ground level, emergency switch off in place, person is more than 600m/2ft away from OLE etc, you or anything holding is more than 600m/2ft away from OLE etc

  • 11

    Name 3 scenarios when you might have to drop,stop,box

    damage to ole,ADD operates but line light doesn’t go out except if there is more than one pantograph on train, line light goes out and have made 1 attempt unsuccessfully to reset, if there is more than 1 panto in use or only panto is not on one of first 3 vehicles

  • routes

    routes

    john collins · 58問 · 1年前

    routes

    routes

    58問 • 1年前
    john collins

    rules dc

    rules dc

    john collins · 5問 · 1年前

    rules dc

    rules dc

    5問 • 1年前
    john collins

    rules g1 pts

    rules g1 pts

    john collins · 9問 · 1年前

    rules g1 pts

    rules g1 pts

    9問 • 1年前
    john collins

    rules m3 managing incidents, floods,snow

    rules m3 managing incidents, floods,snow

    john collins · 9問 · 1年前

    rules m3 managing incidents, floods,snow

    rules m3 managing incidents, floods,snow

    9問 • 1年前
    john collins

    rules p1 single line working

    rules p1 single line working

    john collins · 19問 · 1年前

    rules p1 single line working

    rules p1 single line working

    19問 • 1年前
    john collins

    rules sp speeds

    rules sp speeds

    john collins · 5問 · 1年前

    rules sp speeds

    rules sp speeds

    5問 • 1年前
    john collins

    rules m1 dealing with accident evacuation

    rules m1 dealing with accident evacuation

    john collins · 17問 · 1年前

    rules m1 dealing with accident evacuation

    rules m1 dealing with accident evacuation

    17問 • 1年前
    john collins

    rules m2 train stopped by failure

    rules m2 train stopped by failure

    john collins · 10問 · 1年前

    rules m2 train stopped by failure

    rules m2 train stopped by failure

    10問 • 1年前
    john collins

    rules ss2 shunting

    rules ss2 shunting

    john collins · 6問 · 1年前

    rules ss2 shunting

    rules ss2 shunting

    6問 • 1年前
    john collins

    rules tw5 defective

    rules tw5 defective

    john collins · 10問 · 1年前

    rules tw5 defective

    rules tw5 defective

    10問 • 1年前
    john collins

    rules tw1 prep and movement

    rules tw1 prep and movement

    john collins · 19問 · 1年前

    rules tw1 prep and movement

    rules tw1 prep and movement

    19問 • 1年前
    john collins

    RLU AND FLU TEST

    RLU AND FLU TEST

    john collins · 5問 · 1年前

    RLU AND FLU TEST

    RLU AND FLU TEST

    5問 • 1年前
    john collins

    SHUNTING

    SHUNTING

    john collins · 18問 · 1年前

    SHUNTING

    SHUNTING

    18問 • 1年前
    john collins

    POSSESSION RUNNING LINE ENGINEERING T3

    POSSESSION RUNNING LINE ENGINEERING T3

    john collins · 14問 · 1年前

    POSSESSION RUNNING LINE ENGINEERING T3

    POSSESSION RUNNING LINE ENGINEERING T3

    14問 • 1年前
    john collins

    問題一覧

  • 1

    Minimum distance from ole

    2.75m 9ft

  • 2

    What must you do before asking for switch off if obstruction on another line

    protect obstruction

  • 3

    Rescuing a person within 2.75m 9ft of ole, what distance must they be away from ole

    600mm 2ft

  • 4

    Actions if loss of line light, ADD operation, tripping, damage to ole

    drop,stop,box

  • 5

    Line light goes out, can continue if

    ADD available but not operated, no unusual movement or noises from ole, can reset at first attempt, regain power

  • 6

    Examining ole max speed, when would you need competent person

    20

  • 7

    What are checking when looking at ole

    obstruction not more than 150mm 6in below contact wire, no more than 2 consecutive droppers come off, more than 3 ole structures away from tunnel or overbridge, nothing else obvious

  • 8

    Coasting with pantograph down, max speed

    20

  • 9

    What must you do if told about defective APC track inductor

    shut off power before neutral section

  • 10

    What 4 things must you be sure of before rescuing a person

    alive and can be reached from ground level, emergency switch off in place, person is more than 600m/2ft away from OLE etc, you or anything holding is more than 600m/2ft away from OLE etc

  • 11

    Name 3 scenarios when you might have to drop,stop,box