ログイン

2. Tool Preparation

2. Tool Preparation
31問 • 1年前
  • ユーザ名非公開
  • 通報

    問題一覧

  • 1

    Your second hand asked you. At which pressure the sequence valve will open for TST6? what should your answer be? *

    500

  • 2

    The proper way to load the battery installation sleeve is to insert the thinner end into the tool first

    False

  • 3

    Geologist came to the unit and asked which SLB pressure sensor is the most accurate sensor. for TST What should you tell him?

    ACQG

  • 4

    You received the following chemicals in the support container. Which part is required for the vacuum and fill process?

    HVI DH Oil, DC-11

  • 5

    You have been assigned to TST825 job. When you arrived you found TST675 battery loading tools. Can you still perform the job?

    No

  • 6

    What is the latest commercialized DHS for StethoScope 675 and 825?

    8.7

  • 7

    Which of the following power source would you use to perform the pretest required for the vacuum fill (following class recommendation)

    Battery Power

  • 8

    During pre-job meeting client informed PSDM and D&l that they are not sure about the mobility. Which pretests would you recommend to use to help the client? *

    0-C, TOP

  • 9

    You are loading the battery end cap. What is the proper torque you need to apply?*

    100 ft.Ibf

  • 10

    During the extender checks you measured the resistance for the uphole extender of StethoScope 675. Which of the following is acceptable resistance

    65 kohm

  • 11

    GEN 1 is the point for the pressure which can represents pore pressure during pretest and annular pressure when drilling

    True

  • 12

    The junior LWD engineer asked you about the below parts. Can you help to answer her question? Put your answer in the correct order based on the numbers marked on the photo below

    1 Setting piston 2 Q-ring 3 Spiral pin 4 Packer 5 Filter 6 Set screw

  • 13

    You have completed the tool programming. Which of the following deck test is recommended to be performed?

    0-C

  • 14

    Which of the following pretest is recommended to be used during the flowline fill/vacuum fill procedure?

    0-A

  • 15

    What is the TSIM2 voltage requirement to program and prepare StethoScope tool?

    30V

  • 16

    While performing vacuum fill you noticed the venturi filter is sucking your finger and pressure drop by 5 psi on F9 screen while the air is on. What does this mean?

    Good filter

  • 17

    StethoScope battery has been shipped to your rig. During the preparation of the battery you noticed FTL record of the battery shows life remaining 90% while on the battery package is shows no record which indicated the battery is new at 100% life capacity. Which of the following you should use?

    Battery shouldn't be used since there is discrepancy

  • 18

    During the extender checks your Senior measured the extender go-no-go for the uphole extender of StethoScope 675 and confirmed that it was a GO. What could the measurement have been? Note: StethoScope uphole is box

    1.818

  • 19

    OPRM manager in India location assigned a project for battery optimization and utilization. She asked you which StethoScope pretest will use the maximum battery current

    0-D

  • 20

    StethoScope 825 packer size is the same as StethoScope 675 tool

    False

  • 21

    After the tool programming you are observing the deck pretest. On the F9 screen you notice the BVDC is reading 60V when both hydraulic and pretest motors stopped. What could this mean?

    Voltage is not sufficient to perform the test. Need to redo the physical depassivation

  • 22

    The client foreman (Company Man) informed you that SLB tools will be picked up in 2 days. Which of the below should be done to save the battery life?

    Unlatch the battery using Toolscope

  • 23

    You are on a job in the North Sea in Feb-2020. in the OST it was reported ACQG was calibrated Jan-2019. What action should be taken?

    Raise to OSC and PSDM for the outdated calibration

  • 24

    You have been assigned to a job in Siberia where the temperature was 2deg C. Which of the following is correct when handling lithium battery?

    Take the battery to the unit to warm up after obtaining the proper approval

  • 25

    You received StethoScope 675 tool on the rig. Below photo was taken during the tool physical check. What action you will take

    Collar is pitted and can't be used

  • 26

    While depassivating the lithium battery you noticed the loaded voltage is 62V @25degC. What is your next action?

    Wait 5-15min and repeat the depassivation

  • 27

    What is the maximum working pressure of the flow line strain gauge in psi?

    30000

  • 28

    What is the open circuit voltage in volts of a StethoScope battery?

    88

  • 29

    If you shear the StethoScope setting piston by accident while the tool is in hole you can continue drilling operations without fishing

    True

  • 30

    The compensator lock always has to be in the closed position before RIH

    False

  • 31

    How many setting pistons are on the probe block of a StehtoScope 675 tool?

    1

  • Entrance

    Entrance

    ユーザ名非公開 · 45問 · 1年前

    Entrance

    Entrance

    45問 • 1年前
    ユーザ名非公開

    Mechanics + hydrolics

    Mechanics + hydrolics

    ユーザ名非公開 · 45問 · 1年前

    Mechanics + hydrolics

    Mechanics + hydrolics

    45問 • 1年前
    ユーザ名非公開

    3. Execution and confirmation

    3. Execution and confirmation

    ユーザ名非公開 · 74問 · 1年前

    3. Execution and confirmation

    3. Execution and confirmation

    74問 • 1年前
    ユーザ名非公開

    sonicScope

    sonicScope

    ユーザ名非公開 · 31問 · 10ヶ月前

    sonicScope

    sonicScope

    31問 • 10ヶ月前
    ユーザ名非公開

    問題一覧

  • 1

    Your second hand asked you. At which pressure the sequence valve will open for TST6? what should your answer be? *

    500

  • 2

    The proper way to load the battery installation sleeve is to insert the thinner end into the tool first

    False

  • 3

    Geologist came to the unit and asked which SLB pressure sensor is the most accurate sensor. for TST What should you tell him?

    ACQG

  • 4

    You received the following chemicals in the support container. Which part is required for the vacuum and fill process?

    HVI DH Oil, DC-11

  • 5

    You have been assigned to TST825 job. When you arrived you found TST675 battery loading tools. Can you still perform the job?

    No

  • 6

    What is the latest commercialized DHS for StethoScope 675 and 825?

    8.7

  • 7

    Which of the following power source would you use to perform the pretest required for the vacuum fill (following class recommendation)

    Battery Power

  • 8

    During pre-job meeting client informed PSDM and D&l that they are not sure about the mobility. Which pretests would you recommend to use to help the client? *

    0-C, TOP

  • 9

    You are loading the battery end cap. What is the proper torque you need to apply?*

    100 ft.Ibf

  • 10

    During the extender checks you measured the resistance for the uphole extender of StethoScope 675. Which of the following is acceptable resistance

    65 kohm

  • 11

    GEN 1 is the point for the pressure which can represents pore pressure during pretest and annular pressure when drilling

    True

  • 12

    The junior LWD engineer asked you about the below parts. Can you help to answer her question? Put your answer in the correct order based on the numbers marked on the photo below

    1 Setting piston 2 Q-ring 3 Spiral pin 4 Packer 5 Filter 6 Set screw

  • 13

    You have completed the tool programming. Which of the following deck test is recommended to be performed?

    0-C

  • 14

    Which of the following pretest is recommended to be used during the flowline fill/vacuum fill procedure?

    0-A

  • 15

    What is the TSIM2 voltage requirement to program and prepare StethoScope tool?

    30V

  • 16

    While performing vacuum fill you noticed the venturi filter is sucking your finger and pressure drop by 5 psi on F9 screen while the air is on. What does this mean?

    Good filter

  • 17

    StethoScope battery has been shipped to your rig. During the preparation of the battery you noticed FTL record of the battery shows life remaining 90% while on the battery package is shows no record which indicated the battery is new at 100% life capacity. Which of the following you should use?

    Battery shouldn't be used since there is discrepancy

  • 18

    During the extender checks your Senior measured the extender go-no-go for the uphole extender of StethoScope 675 and confirmed that it was a GO. What could the measurement have been? Note: StethoScope uphole is box

    1.818

  • 19

    OPRM manager in India location assigned a project for battery optimization and utilization. She asked you which StethoScope pretest will use the maximum battery current

    0-D

  • 20

    StethoScope 825 packer size is the same as StethoScope 675 tool

    False

  • 21

    After the tool programming you are observing the deck pretest. On the F9 screen you notice the BVDC is reading 60V when both hydraulic and pretest motors stopped. What could this mean?

    Voltage is not sufficient to perform the test. Need to redo the physical depassivation

  • 22

    The client foreman (Company Man) informed you that SLB tools will be picked up in 2 days. Which of the below should be done to save the battery life?

    Unlatch the battery using Toolscope

  • 23

    You are on a job in the North Sea in Feb-2020. in the OST it was reported ACQG was calibrated Jan-2019. What action should be taken?

    Raise to OSC and PSDM for the outdated calibration

  • 24

    You have been assigned to a job in Siberia where the temperature was 2deg C. Which of the following is correct when handling lithium battery?

    Take the battery to the unit to warm up after obtaining the proper approval

  • 25

    You received StethoScope 675 tool on the rig. Below photo was taken during the tool physical check. What action you will take

    Collar is pitted and can't be used

  • 26

    While depassivating the lithium battery you noticed the loaded voltage is 62V @25degC. What is your next action?

    Wait 5-15min and repeat the depassivation

  • 27

    What is the maximum working pressure of the flow line strain gauge in psi?

    30000

  • 28

    What is the open circuit voltage in volts of a StethoScope battery?

    88

  • 29

    If you shear the StethoScope setting piston by accident while the tool is in hole you can continue drilling operations without fishing

    True

  • 30

    The compensator lock always has to be in the closed position before RIH

    False

  • 31

    How many setting pistons are on the probe block of a StehtoScope 675 tool?

    1