QUIz ANNOUNCEMENT part 2

18 questions • 2024-03-10
Jef Marc Valencia
Report

Question

MONOCHROMATOR of FLUORESCENCE where isolates the ultraviolet light

Answer

Question

MONOCHROMATOR of FLUORESCENCE whereisolates secondary emission (filter, prism or diffraction grating)

Answer

Question

separation of a substance in a pure form and then determining its dry weight

Answer

Question

the unknown sample is made to react with a known solution (titrating agent) in the presence of an indicator

Answer

Question

Chloride determination is also known as

Answer

Question

measurement of the amount of light blocked by a particulate matter suspended in solution (180° to the incident beam)

Answer

Question

Used to quantify protein concentration in urine and CSF, used to measure antibiotic sensitivities from cultures, used to detect clot formation in the sample cuvets

Answer

Question

detection of light energy scattered or reflected toward a detector that is not in the direct path of the transmitted light (90° to the incident beam)

Answer

Question

it is used to measure the disintegration of a radioisotope per minute

Answer

Question

Types of Radiation that is positively charged particles; resemble the nucleus of helium atom with a mass of 4 and Have very little energy

Answer

QUIz ANNOUNCEMENT part 2

TestMaker

Score

0 / 10

Correct rate

0%

Correct: 0

Incorrect: 0

Unanswered: 10

 
ankimaker.com

Question list

  • 1

    MONOCHROMATOR of FLUORESCENCE where isolates the ultraviolet light

    PRIMARY FILTER, EXCITATION FILTER

  • 2

    MONOCHROMATOR of FLUORESCENCE whereisolates secondary emission (filter, prism or diffraction grating)

    SECONDARY FILTER, EMISSION FILTER

  • 3

    separation of a substance in a pure form and then determining its dry weight

    GRAVIMETRIC

  • 4

    the unknown sample is made to react with a known solution (titrating agent) in the presence of an indicator

    VOLUMETRIC, TITRIMETRIC

  • 5

    Chloride determination is also known as

    SCHALES AND SCHALES

  • 6

    measurement of the amount of light blocked by a particulate matter suspended in solution (180° to the incident beam)

    TURBIDIMETRY

  • 7

    Used to quantify protein concentration in urine and CSF, used to measure antibiotic sensitivities from cultures, used to detect clot formation in the sample cuvets

    TURBIDIMETRY

  • 8

    detection of light energy scattered or reflected toward a detector that is not in the direct path of the transmitted light (90° to the incident beam)

    NEPHELOMETRY

  • 9

    it is used to measure the disintegration of a radioisotope per minute

    SCINTILLATION COUNTER

  • 10

    Types of Radiation that is positively charged particles; resemble the nucleus of helium atom with a mass of 4 and Have very little energy

    ALPHA

  • 11

    Types of Radiation that is resembles an electron with both negative (β-) and positive (β+) charges but essentially no mass and Exists in two forms: soft and hard beta

    BETA

  • 12

    Types of Radiation that is a form of electromagnetic energy with no mass, only energy and Exists in two forms: soft and hard gamma

    GAMMA

  • 13

    Types of Scintillation Counters that measures gamma radiation using thallium activated Sodium iodide crystal as scintillator and PM tube as detector with pre-amplifier circuit

    SOLID SCINTILLATION COUNTER, CRYSTAL SCINTILLATION

  • 14

    Types of Scintillation Counters that measures beta radiation using liquid flour as scintillator and Used to count radionuclides that emit beta particles

    LIQUID SCINTILLATION COUNTER

  • 15

    an immunologic procedure involving the use of radioisotope

    RADIOIMMUNOASSAY

  • 16

    RIA:substance being analyzed

    UNLABELLED ANTIGEN

  • 17

    RIA:acts as label

    RADIOLABELLED ANTIGEN

  • 18

    RIA:provide binding site for the two antigens

    ANTIBODY