Question
Travels as electromagnetic wave
Question
the proportion of wavelength and electromagnetic energy is _
Question
TYPES OF ELECTROMAGNETIC ENERGIES
Question
distance between two peaks as the light travels in a wavelike manne
Question
Visible-spectra Wavelength
Question
Ultraviolet region WAVELENGTH
Question
Infrared region WAVELENGTH
Question
Non-visible spectra region
Question
Range region mostly used for toxicology study and determination
Question
Visible spectra color of analytes letter only
Long Discussion ANALYTICAL METHODS & INSTRUMENTATION
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
Travels as electromagnetic waveRADIANT ENERGY, ELECTROMAGNETIC ENERGY
2
the proportion of wavelength and electromagnetic energy is _INVERSELY PROPORTIONAL
3
TYPES OF ELECTROMAGNETIC ENERGIESCOSMIC RAY, GAMMA RAY, X-RAY, VISIBLE, ULTRA VIOLET, INFRARED, MICROWAVE
4
distance between two peaks as the light travels in a wavelike manneWAVELENGTH
5
Visible-spectra Wavelength340-700nm
6
Ultraviolet region WAVELENGTH-340nm
7
Infrared region WAVELENGTH+700nm
8
Non-visible spectra regionULTRAVIOLET, INFRARED
9
Range region mostly used for toxicology study and determinationINFRARED
10
Visible spectra color of analytes letter onlyR, O, Y, G, B, V
11
Chemical reaction produces a colored substance whose concentration is proportional to the analyteCOLORIMETRY
12
COLORIMETRY is based on theQUALITY OF COLOR, INTENSITY OF COLOR
13
Kinds of ColorimetryVISUAL, PHOTOELECTRIC
14
Kind of Colorimetry Relies on visual acuity to determine end-pointVISUAL
15
Kind of Colorimetry The greater the intensity of the color, the result will yield higher alsoVISUAL
16
Kind of Colorimetry primary analytical utility of spectrophotometry or filter photometry is the isolation of discreet portion of spectrum for the purposes of measurementPHOTOELECTRIC
17
Kinds of Photoelectric ColorimetrySPECTROPHOTOMETRY, FILTER PHOTOMETRY
18
Photoelectric Colorimetry where it make use of prisms and/or diffraction gratings as monochromator to disperse the radiant energy into a continuous spectrumSPECTROPHOTOMETRY
19
Photoelectric Colorimetry where it make useof filters (interference or transmission) to isolate part of the spectrumFILTER PHOTOMETRY
20
The amount of light taken up by a solution proportional to the inverse log of transmittanceABSORBANCE
21
Ratio of the radiant energy transmitted to the radiant energy incident on the sample%TRANSMITTANCE
22
TRANSMITTANCE formula It = lo =TRANSMITTED LIGHT TO SAMPLE, INTENSITY OF LIGHT STRIKING SAMPLE
23
LAW OF COLORIMETRY The concentration of the solution is directly proportional to the amount of light absorbed and inversely proportional to the logarithm of transmitted lightBEER'S LAW
24
LAW OF COLORIMETRY Absorbance is directly proportional to the length of light pathBOUGUER'S LAW, LAMBERT'S LAW
25
converts light to electrical energy that can be registered on a read-out device (will show a result of the analyte that are tested)DETECTOR
26
isolates a region from the spectrumMONOCHROMATOR
27
An Internal Component of Spectro that Provides electromagnetic radiation as visible, infrared or UV lightLIGHT SOURCE
28
Most commonly used light sourceTUNGSTEN IODIDE LAMP
29
A light Source which Iodine used to prevent the decomposition on the vaporized tungsten from the hot filament of lightQUARTZ HALIDE LAMP
30
Absorbance is Mathematically derived from%TRANSMITTANCE
31
is a relationship between the attenuation of light through a substance and the properties of that substanceBEER'S LAW
32
Beer's Law formula Where A= a= b= c=ABSORBANCE, MOLAR ABSORPTIVITY, LIGHT PATH OF THE SOLUTION, CONC OF SUBSTANCE
33
Involves measurement of the light transmitted by a solution to determine the concentration of light -absorbing substances in the solutionSPECTROPHOTOMETRY
34
Simplest type of absorption spectrometerSINGLE BEAM
35
It is designed to make one measurement of a time at one specified wavelengthSINGLE BEAM
36
the absorption maximum of the analyte must be known in advance when a single beam instrument is usedSINGLE BEAM
37
An instrument that splits the monochromatic light into two components one beam passes throughout the sample another beam passes through a reference solution or blankDOUBLE BEAM
38
2 Types of Double Beam SpectrophotometerDOUBLE BEAM IN SPACE, DOUBLE BEAM IN TIME
39
w/ 2 photodetectors and all components are duplicated except the light source the beams of light pass-through different components but at the same timeDOUBLE BEAM IN SPACE
40
LIGHT SOURCES which are VISIBLE AND NEAR INFRARED RANGESTUNGSTEN IODIDE LAMP, QUARTZ HALIDE LAMP
41
LIGHT SOURCES which are ULTRAVIOLET RANGESDEUTERIUM DISCHARGE, HOLLOW CATHODE, MERCURY VAPOR, XENON, STRAY, INFRARED
42
Iodine Lamp used to prevent the . decomposition on the vaporized tungsten / from the hot filament of lightHALOGEN QUARTZ
43
Light Source that Provides energy source with high output in the UV range (down to 165 nm)DEUTERIUM DISCHARGE
44
Light Source used above 800nmINFRARED
45
Light Source emits narrow bands of energy at Well-defined places in the spectrum like uV and VisibleMERCURY VAPOR
46
Light Source consists of a gas tight chamber Containing anode, a cylindrical Cathode and inert gas such as helium or argonHOLLOW CATHODE
47
Light Source produces a continuous source of radiation which covers both the UV and visible range. This is not suited for routine application as problems result from stray lightXENON
48
Light source comes from any wavelength outside the band transmitted by the monochromator. Common caused by loss of linearity at high analyte concentrationSTRAY
49
An Internal Component of Spectro reduces stray light and prevent scattered light from entering the monochromator system. It only chooses the amount of light to enter in the dispersion part of monochromatorENTRANCE SLIT
50
An Internal Component of Spectro that produces light of specific wavelength from a light sourceWAVELENGTH SELECTOR, MONOCHROMATOR
51
Defines the range of wavelengths transmitted and is calculated as width at more than half the maximum transmittanceBANDPASS
52
A type of monochromator that is Wedge-shaped pieces of glass, quartz, NaCl, that can be rotatedPRISM
53
A type of monochromator that disperses white light into a continuous spectrum of colors by refractionPRISM
54
A type of monochromator most commonly used monochromator because it has better resolution.DIFFRACTION GRATING
55
A type of monochromator device that has small parallel grooves or slits and acts as prism (refract white light) and has slit (diffract it into several spectra)DIFFRACTION GRATING
56
Prism monochromator PrincipleNON-LINEAR
57
Diffraction Grating Monochromator PrincipleLINEAR
58
A type of monochromator that has Colored glass or colored gelatin sandwiched between two glass platesTRANSMISSION FILTERS
59
In TRANSMISSION FILTERS Light outside the transmission band is absorbed by theCOLORED MATERIAL
60
The Band Pass of TRANSMISSION FILTERS35-50nm
61
A type of monochromator that is Semi-transparent silver films on both sides of dielectric such as MgF. It is not expensive but preciseINTERFERENCE FILTER
62
A type of monochromator that produces monochromatic light based on the principle of constructive interference of wavesINTERFERENCE FILTER
63
An Internal Component of Spectro thatControls the width of light beam (bandpass)- allows , only narrow fraction of the spectrum to reach tha sample cuvetteEXIT SLIT
64
An Internal Component of Spectro with an Internal Dimension of 1 Cm that holds the solution in which the absorption is to be measuredANALYTICAL CELL, CUVETTE, ABSORPTION CELL
65
In Paper Chromatography paper is composed of cellulose; the matrix of cellulose is bound to waterSOLID
66
In Paper Chromatography carries the sample through a bedMOBILE
67
A Chromatography Uses a flat sheet of chromatographic materialTHIN LAYER
68
Analysis based on colors and positionsQUALITATIVE
69
Analysis remove spots and extractQUANTITATIVE
70
Chromatography Separation is based on electrical chargeION-EXCHANGE
71
This capture anionsANION EXCHANGER
72
This capture cationsCATION EXCHANGER
73
Thin Layer Chromatography Solid SupporT water bound toSILICA, ALUMINUM HYDROXIDE
74
Thin Layer Chromatography Mobile PhaseWATER
75
Separation is based on differences in molecular sizeGEL FILTRATION
76
Gel Filtration Stationary phasePOLYACRYLAMIDE, SEPHADEX, POROUS BEAD
77
Gel Filtration Mobile phaseFLOWING WATER
78
general types of Gas Chromatography based on partitionGAS LIQUID
79
general types of Gas Chromatography based on adsorptionGAS SOLID
80
Gas Chromatography Mobile PhaseHELIUM, NITROGEN
81
In Paper Chromatography paper is composed of cellulose; the matrix of cellulose is bound to waterSOLID