  • 1

    A vent in a combustion waste and vent system shall be approximately equal in area to one half.

    Cross section area of the draw pipe

  • 2

    Birth of Plumbing practice in the Philippines

    17th Century

  • 3

    Is a device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures

    Flush valve

  • 4

    Sizing of rainwater piping for two adjacent walls- add _____of the total wall areas to the roof area

    35 %

  • 5

    National Plumbing Code prepared by NAMPAP was Promulgated and approved by Malacanang

    January 28,1959

  • 6

    A structure built, erected and framed of component structure parts designed for the housing, shelter, enclosure or support of person, animals or property of any kind.

    Building

  • 7

    Air test, air is forced into the pipe system until there is a uniform gauge pressure of _____ or sufficient to balance a column of mercury 254 mm in height.

    34.5 kpa

  • 8

    A fixture vent pipe increased one pie size its entire length

    May exceed the maximum horizontal length limited by code

  • 9

    DWV material means

    Drainage, waste and vent

  • 10

    Number of lavatories for Assembly Places(Theather, Auditorium, Convention Halls,etc) for public use for 350-female

    2

  • 11

    The size of supply piping outlet for any gas appliance shall be not less than

    The inlet connection of the appliance

  • 12

    The normal force exerted by a homogeneous liquid or gas per unit of area on the wall of the container

    Pressure

  • 13

    Approval of House Bill No. 962 also known as RA No. 1378

    1954

  • 14

    An open, unoccupied space, bounded on two(2) or more sides by the walls of the building. An inner court is a court entirely within the exterior walls of the building. All other courts are outer courts.

    Court

  • 15

    Cleanouts may omitted on short horizontal drainage pipe installed at a slope of _____ or less from the vertical line ( or an angle _____bend) and;

    72 degree ; 1/5 bend

  • 16

    The pressure available at the fixture or water outlet, allowance is made for pressure drop due at friction loss, head, meter and other losses in the system during maximum demand period

    Residual Pressure

  • 17

    What is the maximum height for the Hose Cabinet to be installed from the floor line?

    4 ft

  • 18

    In what year, NAMPAP President Jaime M. Cabase spearhead the updating of the Revised National Plumbing Code?

    1996

  • 19

    Every passageway to an attic water heater shall have a solid continuous flooring not less than

    24 inches wide

  • 20

    A pressure regulator should be installed when pressure exceeds

    80 psi

  • 21

    A pipe connected from building gutter to the downspout

    leader

  • 22

    Each grease trap shall have an approved water seal of not less than _____in depth or the diameter of its outlet, whichever is greater

    51

  • 23

    Fee for one unit of plumbing as plumbing permit is:

    P 5.00

  • 24

    An impairment of the quality of the water to a degree which creates hazard to the public health and adversely affects the aesthetic and potable qualities of waters for domestic use.

    Pollution

  • 25

    Number of urinal for Office for 420 person

    4

  • 26

    No galvanized wrought iron or galvanized steel pipe shall be used underground and shall be kept at least ___ above ground.

    152 mm

  • 27

    Allowing for friction and other pressure loss the available water pressure for fixture is

    15 psi

  • 28

    What is the interval distance between clean-out along lateral line?

    15 m

  • 29

    Plumbing Code for the City of Manila

    City Ordinance 2411

  • 30

    What is the copper content in brass fitting?

    85%

  • 31

    An approved plumbing fixture or device of such materials, shape and capacity to adequately receive the discharge from indirect waste pipes, constructed and located to readily cleaned

    Receptor

  • 32

    A storm drain sometimes located under the basement floor within the walls of the building

    Inside storm drain

  • 33

    Tube made of plastic material and colored black. The cross-sectional shape is circular and is denotes by its outside diameter or O.D.

    PE or Polyethylene

  • 34

    Dome-type strainers shall have a minimum total net inlet area of ________times the area of the outlet pipe to which it is connected.

    One and one-half

  • 35

    The quantity of water required to be supplied to every plumbing fixture shall be represented by:

    Fixture units

  • 36

    In 1902, he was the first Chief of Plumbing Construction and Inspection

    John F. Hass

  • 37

    A pit or receptacle at a low point to which the liquid waste are drain

    Sump

  • 38

    Which type of fire line installation has become obsolete and seldom installed?

    Local vent

  • 39

    Every building in which plumbing fixture are installed shall have connection to a :

    Public and private sewer

  • 40

    The movement of water to the surface of a soil and into the soil below the surface is

    Infiltration

  • 41

    Revised Plumbing Code of 1999 was approved by President Joseph Estrada

    December 21,1999

  • 42

    All septic tank covers shall be capable of supporting on earth load of not less than ______ when the maximum coverage does not exceed 9m.

    14.4 kpa

  • 43

    Drainage Fixture Unit of water closet, public installation

    6

  • 44

    The lowest portion of the interior part of any pipe or conduit that is not vertical

    Invert

  • 45

    Access to each septic tank shall be provided by at least two(2) manholes _______ in minimum dimension or by an equivalent removable cover slab.

    508 mm

  • 46

    When President Ramon Magsaysay did signed the R.A. 1378, otherwise known as the “PLUMBING LAW OF THE PHILIPPINES”?

    June 18, 1955

  • 47

    Generally, what is the standard diameter of standpipe for buildings two or three stories in height?

    4 in

  • 48

    Generally, what is the standard diameter of standpipe for buildings more than six stories tall?

    6 in

  • 49

    Drainage Fixture Unit of sink, bar, private 38 mm min waste

    1

  • 50

    The indirect waste lines carrying refrigeration waste shall not be smaller than one (1) inlet serving not more than 2.8 mm3 of refrigeration space.

    32 mm

  • 51

    In a line of piping is a combination of elbows or bends, which brings one section of the pipe out of line but into a line parallel with the original section.

    Offset

  • 52

    A term used to described soil or waste system where all piping are threaded pipe tubing or other rigid construction using recessed drainage fitting to correspond to the types of piping

    Durham System

  • 53

    Consists of a loaded air inlet valve, an internally loaded check valve, two properly located test cocks and two isolation gate valves.

    PVB or Pressure Vacuum Breaker Backflow Prevention Assembly

  • 54

    Interceptors or clarifiers for sand and similar heavy solids shall be so designed and located as to be readily accessible for cleaning and shall have a water seal of not less than ____ deep.

    152 mm

  • 55

    A non-watertight lined excavation in the ground which receives the discharge of a sanitary drainage system or part thereof, designed to retain the organic matter and solids discharging therefrom, but permitting the liquid to seep through the bottom and sides of the cesspool.

    Cesspool

  • 56

    Type of Joints for soft copper water tubing shall be made with fittings meeting approved standards. The tubing shall be expanded with a proper flaring tool.

    Flared joints