問題一覧
1
A vent in a combustion waste and vent system shall be approximately equal in area to one half.
Cross section area of the draw pipe
2
Birth of Plumbing practice in the Philippines
17th Century
3
Is a device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures
Flush valve
4
Sizing of rainwater piping for two adjacent walls- add _____of the total wall areas to the roof area
35 %
5
National Plumbing Code prepared by NAMPAP was Promulgated and approved by Malacanang
January 28,1959
6
A structure built, erected and framed of component structure parts designed for the housing, shelter, enclosure or support of person, animals or property of any kind.
Building
7
Air test, air is forced into the pipe system until there is a uniform gauge pressure of _____ or sufficient to balance a column of mercury 254 mm in height.
34.5 kpa
8
A fixture vent pipe increased one pie size its entire length
May exceed the maximum horizontal length limited by code
9
DWV material means
Drainage, waste and vent
10
Number of lavatories for Assembly Places(Theather, Auditorium, Convention Halls,etc) for public use for 350-female
2
11
The size of supply piping outlet for any gas appliance shall be not less than
The inlet connection of the appliance
12
The normal force exerted by a homogeneous liquid or gas per unit of area on the wall of the container
Pressure
13
Approval of House Bill No. 962 also known as RA No. 1378
1954
14
An open, unoccupied space, bounded on two(2) or more sides by the walls of the building. An inner court is a court entirely within the exterior walls of the building. All other courts are outer courts.
Court
15
Cleanouts may omitted on short horizontal drainage pipe installed at a slope of _____ or less from the vertical line ( or an angle _____bend) and;
72 degree ; 1/5 bend
16
The pressure available at the fixture or water outlet, allowance is made for pressure drop due at friction loss, head, meter and other losses in the system during maximum demand period
Residual Pressure
17
What is the maximum height for the Hose Cabinet to be installed from the floor line?
4 ft
18
In what year, NAMPAP President Jaime M. Cabase spearhead the updating of the Revised National Plumbing Code?
1996
19
Every passageway to an attic water heater shall have a solid continuous flooring not less than
24 inches wide
20
A pressure regulator should be installed when pressure exceeds
80 psi
21
A pipe connected from building gutter to the downspout
leader
22
Each grease trap shall have an approved water seal of not less than _____in depth or the diameter of its outlet, whichever is greater
51
23
Fee for one unit of plumbing as plumbing permit is:
P 5.00
24
An impairment of the quality of the water to a degree which creates hazard to the public health and adversely affects the aesthetic and potable qualities of waters for domestic use.
Pollution
25
Number of urinal for Office for 420 person
4
26
No galvanized wrought iron or galvanized steel pipe shall be used underground and shall be kept at least ___ above ground.
152 mm
27
Allowing for friction and other pressure loss the available water pressure for fixture is
15 psi
28
What is the interval distance between clean-out along lateral line?
15 m
29
Plumbing Code for the City of Manila
City Ordinance 2411
30
What is the copper content in brass fitting?
85%
31
An approved plumbing fixture or device of such materials, shape and capacity to adequately receive the discharge from indirect waste pipes, constructed and located to readily cleaned
Receptor
32
A storm drain sometimes located under the basement floor within the walls of the building
Inside storm drain
33
Tube made of plastic material and colored black. The cross-sectional shape is circular and is denotes by its outside diameter or O.D.
PE or Polyethylene
34
Dome-type strainers shall have a minimum total net inlet area of ________times the area of the outlet pipe to which it is connected.
One and one-half
35
The quantity of water required to be supplied to every plumbing fixture shall be represented by:
Fixture units
36
In 1902, he was the first Chief of Plumbing Construction and Inspection
John F. Hass
37
A pit or receptacle at a low point to which the liquid waste are drain
Sump
38
Which type of fire line installation has become obsolete and seldom installed?
Local vent
39
Every building in which plumbing fixture are installed shall have connection to a :
Public and private sewer
40
The movement of water to the surface of a soil and into the soil below the surface is
Infiltration
41
Revised Plumbing Code of 1999 was approved by President Joseph Estrada
December 21,1999
42
All septic tank covers shall be capable of supporting on earth load of not less than ______ when the maximum coverage does not exceed 9m.
14.4 kpa
43
Drainage Fixture Unit of water closet, public installation
6
44
The lowest portion of the interior part of any pipe or conduit that is not vertical
Invert
45
Access to each septic tank shall be provided by at least two(2) manholes _______ in minimum dimension or by an equivalent removable cover slab.
508 mm
46
When President Ramon Magsaysay did signed the R.A. 1378, otherwise known as the “PLUMBING LAW OF THE PHILIPPINES”?
June 18, 1955
47
Generally, what is the standard diameter of standpipe for buildings two or three stories in height?
4 in
48
Generally, what is the standard diameter of standpipe for buildings more than six stories tall?
6 in
49
Drainage Fixture Unit of sink, bar, private 38 mm min waste
1
50
The indirect waste lines carrying refrigeration waste shall not be smaller than one (1) inlet serving not more than 2.8 mm3 of refrigeration space.
32 mm
51
In a line of piping is a combination of elbows or bends, which brings one section of the pipe out of line but into a line parallel with the original section.
Offset
52
A term used to described soil or waste system where all piping are threaded pipe tubing or other rigid construction using recessed drainage fitting to correspond to the types of piping
Durham System
53
Consists of a loaded air inlet valve, an internally loaded check valve, two properly located test cocks and two isolation gate valves.
PVB or Pressure Vacuum Breaker Backflow Prevention Assembly
54
Interceptors or clarifiers for sand and similar heavy solids shall be so designed and located as to be readily accessible for cleaning and shall have a water seal of not less than ____ deep.
152 mm
55
A non-watertight lined excavation in the ground which receives the discharge of a sanitary drainage system or part thereof, designed to retain the organic matter and solids discharging therefrom, but permitting the liquid to seep through the bottom and sides of the cesspool.
Cesspool
56
Type of Joints for soft copper water tubing shall be made with fittings meeting approved standards. The tubing shall be expanded with a proper flaring tool.
Flared joints