  • 1

    A secondary pipeline in sewerage a common sewer to which no other sewer is tributary is called

    Lateral

  • 2

    That pipe which conveys waste water and water carried waste without fecal matter

    Wadte pipe

  • 3

    A bacteria living or active in the absence of free oxygen is called

    Anaerobic

  • 4

    A vent for a single fixtures or battery of fixtures which is connected into the same stack, is not which the fixtures discharge

    Unit vent

  • 5

    A vent which also serve as a drain is called

    Wet vent

  • 6

    A method of installation not allowed in a lateral to avoid pressure and retardation of flow of waste water causing deposition of solid is

    sharp curve

  • 7

    The sanitary drainage system for public health reason, must discharge to

    Public sewer system

  • 8

    What do you call that vents for fixtures intended to ventilate the foul odors and remove air from adjacent area?

    Local vent

  • 9

    What happen when air comes into contact with wastewater in the drainage system

    Dragged along with the fixture along the system

  • 10

    What is that device use to prevent backflow whereby air is admitted to the supply pipe whenever a vacuum occur?

    Vacuum breaker

  • 11

    Pipe materials used inside the buildings and premises shall conform to standard specifications set forth this organization?

    American Society for Testing Materials (ASTM)

  • 12

    When heat is applied to water; molecular activity intensified and such particle expand in itself, followed by the change in behavior

    Increases the volume

  • 13

    What is the prescribed color coding of piping under Steam Division of a high pressure pipe

    White

  • 14

    What is that controlled outlet in a pipeline used to discharge water or drained the system

    Blow-off

  • 15

    Which of the following is not a function of all faucets?

    Level control

  • 16

    What is the basic element of a cold water supply in a building?

    Riser run outs

  • 17

    What is that receptacle installed at corner wall that collect rain water from a balcony

    Scupper drain

  • 18

    What is that system of arrangement of venting so installed that one vent will serve two traps?

    Unit vent

  • 19

    What is the minimum size of fire hose outlet of an interior wet standpipe?

    38 mm dia

  • 20

    A building subdrain is located at what level?

    Below the level of the public sewer

  • 21

    What is the term with reference to the load producing effect on the plumbing system for different kind of plumbing fixtures?

    Fixture unit

  • 22

    Caulk joint shall be firmly packed with oakum or hemp and poured with pure lead, what is that depth of lead over oakum?

    25 mm

  • 23

    What is the depth of the building sewer when installed?

    0.3 m

  • 24

    Which of the following is not a type of lavatory?

    Reverse trap

  • 25

    The connection of sewer service line into a sewer main is made by entering the sewer pipe at what point?

    At the top of the sewer main

  • 26

    What type of end connections which are used for valves smaller than 2 inches in diameter?

    Threaded

  • 27

    What do you call that point which is unobstructed open edge of the fixture?

    Rim

  • 28

    Normally, storm water sho

    Ground water

  • 29

    Dry standpipes shall have sufficient strength to withstand a water pressure of how much when ready for service?

    20 kg/cm2

  • 30

    PD 1095 prescribes that dry standpipe is required for every building of how many floors?

    4 storey or more

  • 31

    On most two-handle faucets, the stems:

    Rotates clockwise & counterclockwise

  • 32

    Flush meter is another name for:

    Flush valve

  • 33

    The water service is a pipe that extends from the

    Water main to the water meter

  • 34

    In term of discharge, one fixture unit represent the flow rate approximately:

    7.48 gal

  • 35

    The area of hole of roof drain to effectively collect and drain rain water in roof is:

    2 x the area of drain pipe

  • 36

    The space between the liquid level line to the inside top cover of septic tank is called:

    Airspace

  • 37

    The trap provision required to restaurant and other establishment where sewage covers large amount of grease prior to discharge to sewer

    Grease trap

  • 38

    It is the pipe extension of a solid or waste stack above the highest horizontal drain connected to the stack

    Stack vent thru roof

  • 39

    It is the arrangement of venting so installed that one vent will serve two traps?

    Unit vent

  • 40

    It is pipe which convey only liquid waste free from fecal matter

    Wet vent

  • 41

    It is a portion of the vent pipe through which liquid waste flow:

    Wet vent

  • 42

    It is a loss of trap seal due to unequal atmospheric pressure condition and due to rapid flows of water thru the trap:

    Siphonage

  • 43

    It is a loss of trap seal due to suspension of foreign object such as string rugs or lint into the trap seal extending over the outlet arm of the trap:

    Capillary attraction

  • 44

    The top cover and the manhole of a septic tank usually extended above the surface of the ground to overcome surface water infiltration

    5 cm

  • 45

    It is a compartment in the septic tank for the settlement of floating or suspended matters, sand debris and any excessive amount of grease or oil from sewage:

    Sedimentation chamber

  • 46

    A septic tank is water tight receptacle for which sewage is digested than a biological action mainly by microorganism such as

    Anaerobic bacteria

  • 47

    The retention period or the time for which suspended matters in septic tank would settle and stabilize is:

    24 hrs

  • 48

    The soil branch must be slope at a grade so that waste content is given a flow of pipe velocity to assure a self-scouring condition and lessen the possibility of seal loss stoppage and retarded flow:

    ¼ inch per foot

  • 49

    The cold-water supply is delivered into the hot water-tank by means of a boiler tube; this tube has a hole within 6 inches from the top of the tank, the purpose of which is to serve as:

    dip tube

  • 50

    What vent pipe installation in the building which has no connection whatsoever with the plumbing fixture

    Exhaust pipe

  • 51

    Water closets shall be computed as ____fixture units when determining septic tank size

    6

  • 52

    Galvanized wrought iron or galvanized steel pipe shall not be used underground and shall be kept at least ____ above ground.

    152 mm

  • 53

    One fixture unit is equivalent to

    1 cu.ft./min

  • 54

    For assembly places for public use, how many water closets are required if the capacity is 115 males?

    2

  • 55

    For assembly places for public use, how many urinals are required if the capacity is 115 males?

    2

  • 56

    There shall be a minimum of ______drinking fountains per occupied floor in schools, theater, auditoriums, dormitories, offices or public building

    1

  • 57

    Drains in gutters in public shower rooms shall be spaced not more than___ apart

    4.9 m

  • 58

    All shower compartments shall have a minimum finished interior area ______sq.m

    0.60 sq. m

  • 59

    Cast iron fitting up to and including 51mm in size, when used in connection with potable water piping shall be_____

    Galvanized

  • 60

    Water pipes shall laid a minimum of ______ above the sewer or drainpipe

    0.30 mm

  • 61

    No building water service pipe shall be less than _____in diameter

    19 mm

  • 62

    Shower head used in private has ___water supply fixture unit

    2

  • 63

    Clean-outs shall be provided at every ____ length or a fraction thereof

    15 m

  • 64

    Clean-out may be omitted on a horizontal drain line less than ____in length

    1.50 m

  • 65

    The minimum slope required for 102 mm diameter pipe or larger drainage piping

    1%

  • 66

    Vent opening shall terminate not less than ____ from any window, door or any opening

    3.0 m

  • 67

    In hospital wards, 1 bath tub or shower shall be provided per ____

    20 patients

  • 68

    Lavatories not affected by side walls, with effective opening not greater than 13 mm dia. Has minimum air gap of _____

    25 mm

  • 69

    Water supply wells shall be located at least _______ from building sewer

    15.2 m

  • 70

    Gate valve used in drainage work having a 102 mm diameter or larger shall have ____bodies

    Cast iron

  • 71

    Manhole in septic tank shall be provided with minimum dimension of _____

    508 mm

  • 72

    Roof deck strainers shall have a total net inlet area less than ______ times the area of the outlet pipe to which the drain is connected.

    2

  • 73

    Which of the following fitting is not recommended to be used in the change of direction in drainage line?

    90 elbow

  • 74

    A private plumbing system is composed of a flush tank water closet, a lavatory, a shower head and faucet. What is the total FU (water supply)?

    9

  • 75

    A pipe fitting, which is threaded on both the inside and the outside so that it can be used to connect two pipes (or other fittings) of different sizes.

    Bushing

  • 76

    A pipe made from an alloy containing 85 percent and 15 percent zinc and generally used in local branch lines and in alteration to match existing work.

    Brass pipe

  • 77

    A small concrete receptacle between the septic tank and the drain field in which lines of drain tiles extends and which acts as surge tank to distribute the flow of sewage equally to each line of drain tiles

    Distribution box

  • 78

    The least expensive but the noisiest water closet; only small amount of standing water-susceptible to fouling, staining and contamination.

    Siphon washdown

  • 79

    A plumbing fixture used for washing the middle part of the body, especially genitals. It is also known as the Sitz Bath.

    Bidet

  • 80

    Minimum trap diameter for laundry tub

    38 mm

  • 81

    It is considered to be the most quiet, most efficient and most sanitary water closet.

    Siphon vortex

  • 82

    Minimum trap diameter for shower bath

    51 mm

  • 83

    A receptacle attached to a plumbing system other than a trap in which water or waste may be collected for ultimate discharge into the plumbing system

    Fixture

  • 84

    Each shower receptor shall be constructed to have a finished dam, curb or threshold of at least _____ mm lower that the outside floor.

    25.4 mm

  • 85

    A plumbing fixture usually located in the operating room in a hospital to enable personnel to scrub their hands prior to a surgical procedure; the hot and cold water supply is activated by a knee-action mixing valve or by wrist or pedal control.

    Scrub sink

  • 86

    This is less esthetic than aeration but more certain oxidation process. It is commolly used in cooling lower treatment and in addition ozonation has very wide range of treatment application

    Ozonation

  • 87

    A pipe within the structure or on the premises which conveys water from the water service pipe or meter to the point of utilization

    Water distribution pipe

  • 88

    What is the size of downspout if the rainfall intensity is 100 mm Ɵ(4”) on a 1200 m2 deck roof

    150 mm dia

  • 89

    What is the size of horizontal rainwater pipe with 2% slope if the max. rainfall is 100 mm on a 206 m 2

    100 mm

  • 90

    How many lavatory shall be installed in a school with 240 male students

    6

  • 91

    What is the size of downspout if the rainfall intensity is 100 mm (4”) if the deck roof is 435 mm 2

    100 mm dia

  • 92

    What is required when cast iron pipe and fittings of different sizes are to be joined or connected?

    An increaser or reducer

  • 93

    What is the fixture unit of 18 storey dormitory building with 6 bathroom group on every floor with class 2

    756

  • 94

    What is the recommended size of service pipe approved by MWSS for a 2 storey residential house?

    ¾” Ɵ - 19 mm

  • 95

    what is the cause of object desirable taste and odor of water

    algae

  • 96

    How does the safety features of a service hot water system works?

    Automatically

  • 97

    What is the minimum size of water supply for water closet flush valve type?

    1 in

  • 98

    How do you measure the rainfall intensity?

    Inches/ hr