Maximum height of a water closet from the floor.0.5
Maximum area of a dumbwaiter.3.9
Maximum slope of a drop curb towards the street.1.2
Maximum slope of a drop curb towards adjoining curb.1.12
Maximum spacing for wheelchair turnabouts.12
Vertical clearance of secondary lines from sidewalks along or crossing the street.7.5
Minimum vertical cl. of primary lines from top of sidewalk when installed along the side of the highway.7.5
Minimum vertical cl. of primary lines from the crown of the pavement when crossing the highway.10
Maximum vertical clearance of an arcade above grade.6
Minimum height of protective railings for temporary walkways.1
Minimum thickness of wire-glass for bath tub5.6
Amount fine for Grave Violation.10k
Violation for non-posting of Occupancy and Building Permit (light, mod, heavy)light
Violation for use without appropriate Occupancy Permit.less grave
Demolition without permitgrave
Air supply per person per minute for auditoriums. cum
0.3
Minimum wind load capacity for roofs for vertical projection.120kg/sqm
Minimum thickness of glass for jalousies.0.56
Maximum length of glass for jalousies.1.2
Number of wheelchair seating for an assembly seating capacity of 51-300.4
Turnabout should also be provided at or whithin how many meters of dead end.3.5
R.A. 7277magna carta for disabled
Accessibility, reachability, usability, orientation, workability and efficiency, and aresafety
How many meterd is the comfortable clearance for knee and leg space under tables for wheelchair users.0.74
How many meters above the floor is the comfortable reach of persons confined to a wheelchair. max 1.200.7
Minimum door width for an accessible elevator.0.8
Maximum height of signs on walls and doors for the disabled to see comfortably.1.6
Minimum with of a parking slot for the disabled.3.7
Minimum Dimensions of an accessible elevator.0.9
Maximum height of 1st the floor for a 2-story wood structure with a height of 7 mts.4.5
Maximum spacing of posts for 2-storey wooden structure with a height of 8 mts.4.5
Under what classification of occupancy does fences of over 1.80 mts in height fall?accessory
Minimum number of exit for an Institutional type of structure.2 exits
raised rim of concrete, stone or metal which forms the edge of street or sidewalk.curb
long interior passageway providing access to several rooms.corridor
Maximum projection of a balcony over a street of 10 mts to less than 11 mts in width.1
Maximum projection of a penthouse or other projections above the roof.8.4
Minimum thickness of walls of masonry chimney for residentials.0.1
Minimum thickness of rubble stone masonry chimney for residentials.0.3
Minimum number of storeys requiring one (1) or more dry standpipes.4
Minimum volume of water a dry standpipe should provide. L/minute900
Diameter of a dry standpipe requiring a two-way Siamese connection.0.1
Diameter of a dry standpipe requiring a three-way Siamese connection.0.125
Diameter of a dry standpipe requiring a four-way Siamese connection.0.15
Minimum-max height of siamese connection on the street-front of the building.0.3 1.2
Maximum projection into a non-arcaded sidewalk of a signboard.1.2
Maximum projection into a arcaded sidewalk of a signboard.0.6
Minimum vertical clearance from the bottom of a signage to an arcaded sidewalk.5
Minimum vertical clearance from the bottom of a signage to non-arcaded sidewalk.3
Number of days of work abandonment of stoppage for a building permit to expire.120
Width of planting strip for sidewalks 2.00 mts in width.0.8
Minimum horizontal distance of the curb line to the outermost face of an arcade.0.5
Slope of driveway to sidewalk where the height of curb is 200 mm and above.1:8
Min. clearance of conductors from any platform or ground or projection from wic they might be reached.3
Minimum clearance of conductors from the highest point of a roof.2.5
Min. vertical cl. of service drop lines above ground at its point of attachment to the building.3
Min. Vertical cl. of a service drop communication line when crossing a street.5.5
Minimum width of an access road to a cul-de-sac.3
Minimum headroom clearance for any stair.2
Maximum slope for an exit passageway.1:8
Maximum height of a Siamese connection above the ground.1.2
Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose.6
Minimum number of exit for any stage.2
Minimum extension of a proscenium wall above the roof.1.2
Minimum width of a stair in a stage egress.0.9
Minimum width of a stair in a stage egress in each fly gallery.0.75
Minimum lateral spacing for plastic skylights.2.5
Minimum spacing for plastic skylights along the slope of the roof.0.3
Minimum distance of a sign from any electrical post or telephone wires.1
Maximum width of a business sign.1.2
Minimum size of thread for an entrance or exit step.0.3
Standard turn circle of a wheelchair.1.5
Max. encroachment into a public sidewalk of a foundation at least 600 mm below the grade.0.5
Max. encroachment into a public highway of a foundation at least 600 mm below the grade.0.3
Minimum dimension of an exit door.0.9
Maximum width reduced by trim, handrails & fully-opened doors to corridors & exit balconies.0.2
Minimum width of stairs serving more than 50 occupants.1.10
Minimum width of stairs serving less than 50 occupants.0.9
Minimum width of stairs serving less than 10 occupants.0.75
Maximum reduction in width of a stair due to trims and handrails.0.1
Minimum run of a winding stair at any point of the steps.0.15
Allowable maximum vatriations tolerance in the rise and run of every step.5 mm
Width of stair requiring an intermediate handrail.3
Minimum width of an aisle serving both sides.1
Minimum width of an aisle serving one side only.1
Minimum distance between the back of each seat to the front of the seat behind it.0.3
Minimum width of side aisles1.1
Minimum width of side aisles serving 1 side only0.8
Max. projection beyond the property line of a footing along the national road and at least 2.40 mts. in depth. (sec 1002.2)0.3
Max. projection beyond the property line of a footing along the sidewalk and at least .60 mts. in depth. (sec 1002.2)0.5
Minimum clearance of a canopy or a marquee from the sidewalk.3
Minimum clearance of an arcade above sidewalk.3
Minimum stair width for occupant load of less than 50.0.9
Minimum stair with for occupant load of more than 50.1.1
Minimum width of a temporary walkway in front of the building.1.2
Maximum with of seat in a stand.0.48
maximum height of a combustible stand
2.7
Minimum spacing for seats in a chair type measurement from back to back
0.85
Maximum line of travel to an exit of an aisle.
45
In standard seating, the minimum spacing of rows measured from back to bac
0.84
Maximum height of a water closet from the floor.0.5
Maximum area of a dumbwaiter.3.9
Maximum slope of a drop curb towards the street.1.2
Maximum slope of a drop curb towards adjoining curb.1.12
Maximum spacing for wheelchair turnabouts.12
Vertical clearance of secondary lines from sidewalks along or crossing the street.7.5
Minimum vertical cl. of primary lines from top of sidewalk when installed along the side of the highway.7.5
Minimum vertical cl. of primary lines from the crown of the pavement when crossing the highway.10
Maximum vertical clearance of an arcade above grade.6
Minimum height of protective railings for temporary walkways.1
Minimum thickness of wire-glass for bath tub5.6
Amount fine for Grave Violation.10k
Violation for non-posting of Occupancy and Building Permit (light, mod, heavy)light
Violation for use without appropriate Occupancy Permit.less grave
Demolition without permitgrave
Air supply per person per minute for auditoriums. cum
0.3
Minimum wind load capacity for roofs for vertical projection.120kg/sqm
Minimum thickness of glass for jalousies.0.56
Maximum length of glass for jalousies.1.2
Number of wheelchair seating for an assembly seating capacity of 51-300.4
Turnabout should also be provided at or whithin how many meters of dead end.3.5
R.A. 7277magna carta for disabled
Accessibility, reachability, usability, orientation, workability and efficiency, and aresafety
How many meterd is the comfortable clearance for knee and leg space under tables for wheelchair users.0.74
How many meters above the floor is the comfortable reach of persons confined to a wheelchair. max 1.200.7
Minimum door width for an accessible elevator.0.8
Maximum height of signs on walls and doors for the disabled to see comfortably.1.6
Minimum with of a parking slot for the disabled.3.7
Minimum Dimensions of an accessible elevator.0.9
Maximum height of 1st the floor for a 2-story wood structure with a height of 7 mts.4.5
Maximum spacing of posts for 2-storey wooden structure with a height of 8 mts.4.5
Under what classification of occupancy does fences of over 1.80 mts in height fall?accessory
Minimum number of exit for an Institutional type of structure.2 exits
raised rim of concrete, stone or metal which forms the edge of street or sidewalk.curb
long interior passageway providing access to several rooms.corridor
Maximum projection of a balcony over a street of 10 mts to less than 11 mts in width.1
Maximum projection of a penthouse or other projections above the roof.8.4
Minimum thickness of walls of masonry chimney for residentials.0.1
Minimum thickness of rubble stone masonry chimney for residentials.0.3
Minimum number of storeys requiring one (1) or more dry standpipes.4
Minimum volume of water a dry standpipe should provide. L/minute900
Diameter of a dry standpipe requiring a two-way Siamese connection.0.1
Diameter of a dry standpipe requiring a three-way Siamese connection.0.125
Diameter of a dry standpipe requiring a four-way Siamese connection.0.15
Minimum-max height of siamese connection on the street-front of the building.0.3 1.2
Maximum projection into a non-arcaded sidewalk of a signboard.1.2
Maximum projection into a arcaded sidewalk of a signboard.0.6
Minimum vertical clearance from the bottom of a signage to an arcaded sidewalk.5
Minimum vertical clearance from the bottom of a signage to non-arcaded sidewalk.3
Number of days of work abandonment of stoppage for a building permit to expire.120
Width of planting strip for sidewalks 2.00 mts in width.0.8
Minimum horizontal distance of the curb line to the outermost face of an arcade.0.5
Slope of driveway to sidewalk where the height of curb is 200 mm and above.1:8
Min. clearance of conductors from any platform or ground or projection from wic they might be reached.3
Minimum clearance of conductors from the highest point of a roof.2.5
Min. vertical cl. of service drop lines above ground at its point of attachment to the building.3
Min. Vertical cl. of a service drop communication line when crossing a street.5.5
Minimum width of an access road to a cul-de-sac.3
Minimum headroom clearance for any stair.2
Maximum slope for an exit passageway.1:8
Maximum height of a Siamese connection above the ground.1.2
Maximum distance of any portion of a building from the nozzle of a 23 mts fire hose.6
Minimum number of exit for any stage.2
Minimum extension of a proscenium wall above the roof.1.2
Minimum width of a stair in a stage egress.0.9
Minimum width of a stair in a stage egress in each fly gallery.0.75
Minimum lateral spacing for plastic skylights.2.5
Minimum spacing for plastic skylights along the slope of the roof.0.3
Minimum distance of a sign from any electrical post or telephone wires.1
Maximum width of a business sign.1.2
Minimum size of thread for an entrance or exit step.0.3
Standard turn circle of a wheelchair.1.5
Max. encroachment into a public sidewalk of a foundation at least 600 mm below the grade.0.5
Max. encroachment into a public highway of a foundation at least 600 mm below the grade.0.3
Minimum dimension of an exit door.0.9
Maximum width reduced by trim, handrails & fully-opened doors to corridors & exit balconies.0.2
Minimum width of stairs serving more than 50 occupants.1.10
Minimum width of stairs serving less than 50 occupants.0.9
Minimum width of stairs serving less than 10 occupants.0.75
Maximum reduction in width of a stair due to trims and handrails.0.1
Minimum run of a winding stair at any point of the steps.0.15
Allowable maximum vatriations tolerance in the rise and run of every step.5 mm
Width of stair requiring an intermediate handrail.3
Minimum width of an aisle serving both sides.1
Minimum width of an aisle serving one side only.1
Minimum distance between the back of each seat to the front of the seat behind it.0.3
Minimum width of side aisles1.1
Minimum width of side aisles serving 1 side only0.8
Max. projection beyond the property line of a footing along the national road and at least 2.40 mts. in depth. (sec 1002.2)0.3
Max. projection beyond the property line of a footing along the sidewalk and at least .60 mts. in depth. (sec 1002.2)0.5
Minimum clearance of a canopy or a marquee from the sidewalk.3
Minimum clearance of an arcade above sidewalk.3
Minimum stair width for occupant load of less than 50.0.9
Minimum stair with for occupant load of more than 50.1.1
Minimum width of a temporary walkway in front of the building.1.2
Maximum with of seat in a stand.0.48
maximum height of a combustible stand
2.7
Minimum spacing for seats in a chair type measurement from back to back
0.85
Maximum line of travel to an exit of an aisle.
45
In standard seating, the minimum spacing of rows measured from back to bac
0.84