Question
MONOCHROMATOR of FLUORESCENCE where isolates the ultraviolet light
Question
MONOCHROMATOR of FLUORESCENCE whereisolates secondary emission (filter, prism or diffraction grating)
Question
separation of a substance in a pure form and then determining its dry weight
Question
the unknown sample is made to react with a known solution (titrating agent) in the presence of an indicator
Question
Chloride determination is also known as
Question
measurement of the amount of light blocked by a particulate matter suspended in solution (180° to the incident beam)
Question
Used to quantify protein concentration in urine and CSF, used to measure antibiotic sensitivities from cultures, used to detect clot formation in the sample cuvets
Question
detection of light energy scattered or reflected toward a detector that is not in the direct path of the transmitted light (90° to the incident beam)
Question
it is used to measure the disintegration of a radioisotope per minute
Question
Types of Radiation that is positively charged particles; resemble the nucleus of helium atom with a mass of 4 and Have very little energy
QUIz ANNOUNCEMENT part 2
Score
0 / 10
Correct rate
0%
Correct: 0
Incorrect: 0
Unanswered: 10
Question list
1
MONOCHROMATOR of FLUORESCENCE where isolates the ultraviolet lightPRIMARY FILTER, EXCITATION FILTER
2
MONOCHROMATOR of FLUORESCENCE whereisolates secondary emission (filter, prism or diffraction grating)SECONDARY FILTER, EMISSION FILTER
3
separation of a substance in a pure form and then determining its dry weightGRAVIMETRIC
4
the unknown sample is made to react with a known solution (titrating agent) in the presence of an indicatorVOLUMETRIC, TITRIMETRIC
5
Chloride determination is also known asSCHALES AND SCHALES
6
measurement of the amount of light blocked by a particulate matter suspended in solution (180° to the incident beam)TURBIDIMETRY
7
Used to quantify protein concentration in urine and CSF, used to measure antibiotic sensitivities from cultures, used to detect clot formation in the sample cuvetsTURBIDIMETRY
8
detection of light energy scattered or reflected toward a detector that is not in the direct path of the transmitted light (90° to the incident beam)NEPHELOMETRY
9
it is used to measure the disintegration of a radioisotope per minuteSCINTILLATION COUNTER
10
Types of Radiation that is positively charged particles; resemble the nucleus of helium atom with a mass of 4 and Have very little energyALPHA
11
Types of Radiation that is resembles an electron with both negative (β-) and positive (β+) charges but essentially no mass and Exists in two forms: soft and hard betaBETA
12
Types of Radiation that is a form of electromagnetic energy with no mass, only energy and Exists in two forms: soft and hard gammaGAMMA
13
Types of Scintillation Counters that measures gamma radiation using thallium activated Sodium iodide crystal as scintillator and PM tube as detector with pre-amplifier circuitSOLID SCINTILLATION COUNTER, CRYSTAL SCINTILLATION
14
Types of Scintillation Counters that measures beta radiation using liquid flour as scintillator and Used to count radionuclides that emit beta particlesLIQUID SCINTILLATION COUNTER
15
an immunologic procedure involving the use of radioisotopeRADIOIMMUNOASSAY
16
RIA:substance being analyzedUNLABELLED ANTIGEN
17
RIA:acts as labelRADIOLABELLED ANTIGEN
18
RIA:provide binding site for the two antigensANTIBODY