  • 1

    Utilizes 100 polypropylene balls that are 3/4" in Diameter

    Ball Removal Test

  • 2

    Utilizes approximately 2500 disc shaped granules of polyethylene

    Granule Test

  • 3

    In granule test initial flush of three different flushes must result in no more than _____granules on average remaining in the bowl

    125

  • 4

    A felt-tip marker is used to draw a line around the inside of the bowl. After flushing, no individual segment can exceed 1/2".

    Ink Test

  • 5

    The total lenght of of the remaining ink line must not exceed _____

    2"

  • 6

    Performed on the inside wall of the water closet bowl

    Ink Test

  • 7

    Uses a colored dye added to the water closet's trap seal

    Dye Test

  • 8

    A dillution ratio of _____ must be obtained for each flush

    100:1

  • 9

    This test determine the evacuation of urine in the trap seal

    Dye Test

  • 10

    It determines if the water closet meets the federal mandate of 1.6gpf

    Water Consumption Test

  • 11

    Remaining trap seal must be a minimum of 2" in depth

    Water Consumption Test

  • 12

    It evaluates the rise of water in the bowl when the water closet is flushed

    Water Rise Test

  • 13

    The Water cannot rise _____below the top of the bowl

    3"

  • 14

    Used to determine that the water Seal remains in place when exposed to a back pressure test

    The Back Pressure Test

  • 15

    Water Column required for back pressure test

    2 1/2"

  • 16

    Determines that no sewer gas will escape through the fixture when high pressure occurs in the drainage system

    The Back Pressure Test

  • 17

    Determines if the water splashes onto top of the rim or seat of the water closet

    Rim Top and Seat Fouling Test

  • 18

    Ensure that the user does not encounter a wet seat when using the water closet

    Rim Top and Seat Fouling Test

  • 19

    Determines the performance of the water closet's flush

    Drainline Carry Test

  • 20

    How does Drainline Carry Test is done?

    Connected to a 4" drain 60 feet in length pitched 2%

  • 21

    Determines the ability of the WC to flush the contents in such a manner that they properly flow down the drainage piping

    Drainline Carry Test

  • 22

    The average carry distance of all Polypropylene balls must be ___ in drain line carry test

    40 feet

  • 23

    A test of large quantity of items placed in the bowl

    Bulk media test