    Proper functioning of the bowl is dependent upon siphonic action in the trapway accelerated by the force of water from the jet directed over a dam

    Washdown

  • 2

    Water Enters through an open rim, as though bucket of water were dumped in the bowl, filling the front trapway and creating a siphon action.

    Washdown

  • 3

    Simple in construction and yet highly efficient within its limitation.

    Washdown

  • 4

    Particularly suitable for installation with flush valves or low tanks

    Reverse Trap

  • 5

    Water enters through rim punchinggs and through a jet that fills the rear trapway completely, creating a siphon action and resulting in quick withdrawal of water from the bowl

    Reverse Trap

  • 6

    Flushing action of the siphon jet bowl is accomplished by a jet of water being directed through the upleg of the trapway

    Siphon Jet

  • 7

    Water enters through diagonal punching around the rim of the bowl, creating a vortex that draws the water down into the rear trap with a swirling action that scours the walls of the bowl

    Siphon Vortex

  • 8

    Large water surface provides a very efficient and clean process and the flushing is extremely quiet

    Siphon Vortex

  • 9

    Operated with flush valves only

    Blowout

  • 10

    depends entirely upon a driving jet action for tis efficieny rather than upon siphonic action in the trapway

    Blowout

  • 11

    Economical in the use of water, yet gas a large water surface that reduces fouling space, a deep-water seal and a large unrestricted trapway

    Blowout

  • 12

    Especially suitable for use in schools, offices and public buildings

    Blowout

  • 13

    Flow Rates of WC

    1.6gpf

  • 14

    Standard Rough in bowl outlet

    12"

  • 15

    Height of water closet rim for children

    10"

  • 16

    Juveneille Water closet height

    13"

  • 17

    Standard Water Closet Rim Height

    14-15"

  • 18

    Maximum flow rate for flushing of urinal

    1.0 gpf

  • 19

    flow rates for private lavatory

    2.2 gpm @ 60psi

  • 20

    flow rates for public lavatories

    0.50 gpm @ 60 psi

  • 21

    flow rates for lavatpry public metering

    0.25gal

  • 22

    Standard height of lavatory from the floor

    31"

  • 23

    rough in height of cold watery supply for lavatory from the lavatory

    10"