Запитання
To identify a drug by means of thin-layer chromatography the following parameter is used:
Запитання
Choose the pair of electrodes for potentiometric pH measurement of a solution:
Запитання
Electrode made according to the scheme Red, Ox, H+ | Pt belongs to the following type:
Запитання
In the process of conductometric titration of HCl and CH3COOH acids mixture 0,1 M solution of NaOH is used to measure:
Запитання
Gas chromatography has been used for ethanol quantitative determination. What parameter is measured?
Запитання
Select a pair of electrodes for potentiometric pH measurement of a solution:
Запитання
What solution can be determined by photocolorimetric method by selfabsorbance?
Запитання
What substance in a solution can be determined in two ways - by the polarimetric or refractometric method?
Запитання
An analytical chemist determines sodium cations by ion-exchange chromatography. In order to prepare the cation-exchange resin in the H+ form, the analyst uses:
Запитання
Choose a pair of electrodes for potentiometric pH measurement of a solution:
инструм англ
Результат
0 / 10
Відсоток правильних відповідей
0%
Правильно: 0
Неправильно: 0
Невідповідано: 10
Список запитань
1
To identify a drug by means of thin-layer chromatography the following parameter is used:Rf
2
Choose the pair of electrodes for potentiometric pH measurement of a solution:Glass and silver chloride
3
Electrode made according to the scheme Red, Ox, H+ | Pt belongs to the following type:Complex redox electrode
4
In the process of conductometric titration of HCl and CH3COOH acids mixture 0,1 M solution of NaOH is used to measure:Electrical conduction in solution
5
Gas chromatography has been used for ethanol quantitative determination. What parameter is measured?Chromatographic peak height or area
6
Select a pair of electrodes for potentiometric pH measurement of a solution:Glass and silver chloride
7
What solution can be determined by photocolorimetric method by selfabsorbance?Potassium chromate
8
What substance in a solution can be determined in two ways - by the polarimetric or refractometric method?Ascorbic acid
9
An analytical chemist determines sodium cations by ion-exchange chromatography. In order to prepare the cation-exchange resin in the H+ form, the analyst uses:HCI
10
Choose a pair of electrodes for potentiometric pH measurement of a solution:Glass and silver chloride
11
Drugs are commonly analyzed by means of potentiometric pH measurement. Which of the electrodes can be used for measuring the solution pH?Glass
12
For the quantitative analysis of ethanol the gas chromatography was used. Which parameter was measured?Peak height or area
13
The polarographic method is commonly used for the analysis of inorganic cations and anions. Electroreduction of the analyzed ions is performed by using:Dropping mercury electrode
14
Potentiometric method of pH determination is regarded as the most universal and enters into the National Pharmacopeia of Ukraine. Which electrode is used as a reference electrode?Saturated calomel
15
During thin-layer chromatography of novocaine, the developed plate represented a stain 3 cm away from the start line, and the length of solvent front was 10 cm. What is the Rf value of novocaine?0,3
16
What electrode is used as indicator during dichromatometric determination of F eSO4 in a solution provided that fi- xation of the equivalence point is done by a potentiometric method?Platinum
17
During study of pharmaceutical substances pH rate can be determined by method of potentiometry. What electrode can be used as an indicator during measuring of pH solution?Glass
18
During quantitative estimation of glucose by polarimetric method the following factor is measured:Angle of rotation of polarized beam plane
19
Choose a pair of electrodes for F eSO4 determination by method of potentiometric titration:Platinum and chlorosilver
20
Coulometry is based upon measurement of electrics that is spent on electrode reaction. What law underlies coulometric method?Faraday law
21
For dichromatometric determination of F eSO4 content in the solution with potentiometric fixation of equivalence point the following indicator electrode is applied:Platinum