FOR GRAD COMP 5
問題一覧
1
impulse
2
pump would stop
3
distillate pump
4
first close the ahead throttle valve, then open the astern guardian valve, and then open the astern throttle to admit astern steam as quickly as possible
5
only when instructed by the chief engineer
6
pump would overheat
7
machinery space bilges
8
Allow the sediments and water to settle
9
all of the above
10
pump suction line
11
stripper
12
suction valve is closed
13
check valve
14
before the pump
15
easy transfer and meet parameter for ignition quality
16
viscosity
17
pump and the starting motor
18
air reservoir
19
pump-ability of the oil
20
ODM (Oil discharge monitor)
21
isolation valves
22
diffuser pump
23
dirty fuel
24
all of the above
25
I, II and III
26
Bilge system will lose vacuum and prevent the other bilges from being pumped out
27
High suction sea chest
28
dirty fuel strainers
29
silica gel
30
improved atomization
31
a leak in a gasket on the suction side of the pump
32
they can be economically replace as they wear out
33
bunkering plan
34
in the sump tank
35
looking at the overflow sightglass
36
drain valve
37
Chief Officer
38
top of the casing
39
cooling water pump outlet
FOR GRAD COMP 1
FOR GRAD COMP 1
ROEL VINCENT CATUBUAN · 35問 · 2年前FOR GRAD COMP 1
FOR GRAD COMP 1
35問 • 2年前FOR GRAD COMP 2
FOR GRAD COMP 2
ROEL VINCENT CATUBUAN · 20問 · 2年前FOR GRAD COMP 2
FOR GRAD COMP 2
20問 • 2年前FOR GRAD COMP 3
FOR GRAD COMP 3
ROEL VINCENT CATUBUAN · 17問 · 2年前FOR GRAD COMP 3
FOR GRAD COMP 3
17問 • 2年前FOR GRAD COMP 4
FOR GRAD COMP 4
ROEL VINCENT CATUBUAN · 48問 · 2年前FOR GRAD COMP 4
FOR GRAD COMP 4
48問 • 2年前FOR GRAD COMP 7
FOR GRAD COMP 7
ROEL VINCENT CATUBUAN · 12問 · 2年前FOR GRAD COMP 7
FOR GRAD COMP 7
12問 • 2年前FOR GRAD COMP 8
FOR GRAD COMP 8
ROEL VINCENT CATUBUAN · 10問 · 2年前FOR GRAD COMP 8
FOR GRAD COMP 8
10問 • 2年前FOR GRAD COMP 9
FOR GRAD COMP 9
ROEL VINCENT CATUBUAN · 57問 · 2年前FOR GRAD COMP 9
FOR GRAD COMP 9
57問 • 2年前FOR GRAD FUNC 10
FOR GRAD FUNC 10
ROEL VINCENT CATUBUAN · 27問 · 2年前FOR GRAD FUNC 10
FOR GRAD FUNC 10
27問 • 2年前FOR GRAD COMP 11
FOR GRAD COMP 11
ROEL VINCENT CATUBUAN · 29問 · 2年前FOR GRAD COMP 11
FOR GRAD COMP 11
29問 • 2年前FOR GRAD COMP 12
FOR GRAD COMP 12
ROEL VINCENT CATUBUAN · 26問 · 2年前FOR GRAD COMP 12
FOR GRAD COMP 12
26問 • 2年前FOR GRAD COMP 13
FOR GRAD COMP 13
ROEL VINCENT CATUBUAN · 10問 · 2年前FOR GRAD COMP 13
FOR GRAD COMP 13
10問 • 2年前FOR GRAD FUNC 14
FOR GRAD FUNC 14
ROEL VINCENT CATUBUAN · 5問 · 2年前FOR GRAD FUNC 14
FOR GRAD FUNC 14
5問 • 2年前FOR GRAD COMP 15
FOR GRAD COMP 15
ROEL VINCENT CATUBUAN · 18問 · 2年前FOR GRAD COMP 15
FOR GRAD COMP 15
18問 • 2年前FOR GRAD COMP 16
FOR GRAD COMP 16
ROEL VINCENT CATUBUAN · 7問 · 2年前FOR GRAD COMP 16
FOR GRAD COMP 16
7問 • 2年前問題一覧
1
impulse
2
pump would stop
3
distillate pump
4
first close the ahead throttle valve, then open the astern guardian valve, and then open the astern throttle to admit astern steam as quickly as possible
5
only when instructed by the chief engineer
6
pump would overheat
7
machinery space bilges
8
Allow the sediments and water to settle
9
all of the above
10
pump suction line
11
stripper
12
suction valve is closed
13
check valve
14
before the pump
15
easy transfer and meet parameter for ignition quality
16
viscosity
17
pump and the starting motor
18
air reservoir
19
pump-ability of the oil
20
ODM (Oil discharge monitor)
21
isolation valves
22
diffuser pump
23
dirty fuel
24
all of the above
25
I, II and III
26
Bilge system will lose vacuum and prevent the other bilges from being pumped out
27
High suction sea chest
28
dirty fuel strainers
29
silica gel
30
improved atomization
31
a leak in a gasket on the suction side of the pump
32
they can be economically replace as they wear out
33
bunkering plan
34
in the sump tank
35
looking at the overflow sightglass
36
drain valve
37
Chief Officer
38
top of the casing
39
cooling water pump outlet