Feb 2024 PB3

Feb 2024 PB3
44問 • 2024-02-27
  • ユーザ名非公開
  • 通報

    Feb 2024 PB2

    Feb 2024 PB2

    ユーザ名非公開 · 26問 · 2年前

    Feb 2024 PB2

    Feb 2024 PB2

    26問 • 2年前
    ユーザ名非公開

    Feb 2024 PB4

    Feb 2024 PB4

    ユーザ名非公開 · 19問 · 2年前

    Feb 2024 PB4

    Feb 2024 PB4

    19問 • 2年前
    ユーザ名非公開

    Summary of Material Thickness and Weight

    Summary of Material Thickness and Weight

    ユーザ名非公開 · 19問 · 2年前

    Summary of Material Thickness and Weight

    Summary of Material Thickness and Weight

    19問 • 2年前
    ユーザ名非公開

    Feb 2024 PB5

    Feb 2024 PB5

    ユーザ名非公開 · 7問 · 2年前

    Feb 2024 PB5

    Feb 2024 PB5

    7問 • 2年前
    ユーザ名非公開

    Possible Questions

    Possible Questions

    ユーザ名非公開 · 6問 · 2年前

    Possible Questions

    Possible Questions

    6問 • 2年前
    ユーザ名非公開

    Clamps and Hangers Figures

    Clamps and Hangers Figures

    ユーザ名非公開 · 18問 · 2年前

    Clamps and Hangers Figures

    Clamps and Hangers Figures

    18問 • 2年前
    ユーザ名非公開

    Hammers

    Hammers

    ユーザ名非公開 · 7問 · 2年前

    Hammers

    Hammers

    7問 • 2年前
    ユーザ名非公開

    Pliers

    Pliers

    ユーザ名非公開 · 22問 · 2年前

    Pliers

    Pliers

    22問 • 2年前
    ユーザ名非公開

    問題一覧

  • 1

    Minimum length of any branch requiring separate venting.

    4.6 m

  • 2

    Minimum number of stories served by a waste stack requiring a paraliel vent stack.

    10

  • 3

    Maximum distance of any under floor clean out from any access door, crawl space, or crawl hole.

    6.1 m

  • 4

    Vent pipe size for lavatories, drinking fountain.

    1 1/2 in

  • 5

    Vent pipe size for sink.

    1 1/2 in

  • 6

    Vent pipe size for shower, laundry, slop sinks.

    1 in

  • 7

    Vent pipe size for water closet

    3”

  • 8

    Maximum length requirement to have a clean-out.

    15 m

  • 9

    Length of horizontal drain which does not require a clean-out unless such line is serving sinks or urinal.

    1.5 m or less

  • 10

    Size of cleanout for pipe size of 38 mm diameter.

    38 mm

  • 11

    Size of cleanout for pipe size of 51 mm diameter.

    38 mm

  • 12

    Size of cleanout for pipe size of 64 mm diameter.

    64 mm

  • 13

    Size of cleanout for pipe size of 76 mm diameter.

    64 mm

  • 14

    Size of cleanout for pipe size of 89 mm diameter.

    102 mm or larger

  • 15

    Minimum distance of water closet center to side wall.

    0.375 m

  • 16

    Minimum distance of water closet center to water closet center.

    0.75 m

  • 17

    Minimum distance of urinal center to side wall.

    0.30 m

  • 18

    Minimum distance of urinal center to urinal center.

    0.6 m

  • 19

    Minimum distance of bidet center to side wall.

    0.375 m

  • 20

    Minimum distance of bidet center to bidet center.

    0.75 m

  • 21

    Minimum slope of shower receptor.

    2%

  • 22

    Maximum slope of shower receptor.

    4%

  • 23

    Minimum height of threshold for shower wide door.

    559 mm

  • 24

    Minimum interior area of shower compartment.

    0.6 sqm

  • 25

    Minimum spacing of drains for gang shower.

    4.9 m

  • 26

    Mounting height of wall hung lavatory from the FFL.

    32” or 0.8 m

  • 27

    Maximum mounting height of toilet grab bars from FFL.

    36” or 0.9 m

  • 28

    Maximum mounting height of tissue paper holder from FFL.

    19”

  • 29

    Minimum NPS of fixture supply pipe for toilet.

    3/8”

  • 30

    Minimum NPS of fixture supply pipe for bidet.

    3/8”

  • 31

    Minimum NPS of fixture supply pipe for tank type water closet.

    3/8”

  • 32

    Minimum NPS of fixture supply pipe for shower.

    1/2”

  • 33

    Minimum NPS of fixture supply pipe for kitchen sink.

    1/2”

  • 34

    Minimum NPS of fixture supply pipe for bathtub.

    1/2”

  • 35

    Minimum fixture drain size for a water closet.

    3”

  • 36

    Minimum fixture drain size for a bathtub.

    1.5”

  • 37

    Minimum depth of water seal for trap.

    2”

  • 38

    Maximum depth of water seal for trap.

    4”

  • 39

    Minimum trap diameter for a shower stall.

    2”

  • 40

    Minimum size of waste branch for a shower stall.

    2”

  • 41

    Minimum height of a water seal for each fixture trap.

    51 mm

  • 42

    Minimum water seal depth or outlet diameter of grease trap.

    51 mm

  • 43

    Maximum height of a water seal for each fixture trap.

    102 mm

  • 44

    Minimum trap diameter for a bathtub.

    1 1/2 in