問題一覧
1
Avoid dropping into water as this shall short circuit the batteries
2
Is a triple frequency transmitter
3
When a rescue party is seen or heard
4
Unscrew the base and disconnect the wire harness
5
Is a manually activated transmitter
6
During a crash landing or a ditching
7
During a ditching ELT should be tied on to the raft diagonally opposite the sea anchor
8
For both above situations
9
Ensure the red light is flashing every 4 - 6 seconds
10
Inflate only one chamber during phase 2
11
Is a polished steel plate with an opening in the center for signaling
12
Push the safety catch down and squeeze both levers together
13
Hand activated freshwater maker with a suction and pump action
14
Has a water activated battery and would last for 8 hours once activated
15
At the door sill prior to boarding raft by pulling the activation tabs
16
Ensure face is free of make-up / Neck seal is airtight / Activate PBE
17
Inflate cot, Wrap the infant in a blanket and secure with the restraining straps
18
The toggle switch should be in the OFF position
19
Push the center tube down, hold down wind, unscrew cap and pull chain to activate
20
Oxygen flow will start automatically once worn
21
The green disc is visible and security seal intact
22
The loop has to be passed through the belt on to the side without the airbag
23
Ensure the red disc marked "FULL" is intact
24
Flip safety catch up and squeeze palm lever
25
ADT 406 AP - Transmission commences 30 seconds after activation
26
CCMs shall smother minor fires and grasp hot or burning parts
27
Flip the safety catch up, aim at the base of the fire and squeeze the palm lever
28
Immediately dip the flare in water to cool and dispose
29
The mask shall be fitted to the high outlet and the tubing shall not be damaged
30
Shall be used on all classes of fires safely and effectively
31
The Foil bag does not touch the viewing window
32
20
33
Tie the ELT onto the lifeline and throw into the water for activation
34
Is a manually activated transmitter and civil & military frequencies shall last for 60 hrs
MPLE
MPLE
ユーザ名非公開 · 41問 · 13日前MPLE
MPLE
41問 • 13日前Weekly Test 3
Weekly Test 3
ユーザ名非公開 · 50問 · 13日前Weekly Test 3
Weekly Test 3
50問 • 13日前Weekly Test 1
Weekly Test 1
ユーザ名非公開 · 50問 · 13日前Weekly Test 1
Weekly Test 1
50問 • 13日前Refresher SPDI 1
Refresher SPDI 1
ユーザ名非公開 · 9問 · 13日前Refresher SPDI 1
Refresher SPDI 1
9問 • 13日前Refresher SPDI 1
Refresher SPDI 1
ユーザ名非公開 · 100問 · 13日前Refresher SPDI 1
Refresher SPDI 1
100問 • 13日前Definition of Terms 2
Definition of Terms 2
ユーザ名非公開 · 90問 · 13日前Definition of Terms 2
Definition of Terms 2
90問 • 13日前Standpipe Requirements
Standpipe Requirements
ユーザ名非公開 · 29問 · 13日前Standpipe Requirements
Standpipe Requirements
29問 • 13日前Principles and Code of Ethics
Principles and Code of Ethics
ユーザ名非公開 · 29問 · 13日前Principles and Code of Ethics
Principles and Code of Ethics
29問 • 13日前RNPCP Chapter 10 to 13
RNPCP Chapter 10 to 13
ユーザ名非公開 · 93問 · 13日前RNPCP Chapter 10 to 13
RNPCP Chapter 10 to 13
93問 • 13日前RNPCP Chapter 6 to 9
RNPCP Chapter 6 to 9
ユーザ名非公開 · 94問 · 13日前RNPCP Chapter 6 to 9
RNPCP Chapter 6 to 9
94問 • 13日前Practical Problems and Experiences REFRESHER 2
Practical Problems and Experiences REFRESHER 2
ユーザ名非公開 · 70問 · 13日前Practical Problems and Experiences REFRESHER 2
Practical Problems and Experiences REFRESHER 2
70問 • 13日前Practical Problems and Experiences REFRESHER 1
Practical Problems and Experiences REFRESHER 1
ユーザ名非公開 · 100問 · 13日前Practical Problems and Experiences REFRESHER 1
Practical Problems and Experiences REFRESHER 1
100問 • 13日前Plumbing Code WSFU
Plumbing Code WSFU
ユーザ名非公開 · 58問 · 13日前Plumbing Code WSFU
Plumbing Code WSFU
58問 • 13日前Sanitation, Plumbing Design, and Installation 3
Sanitation, Plumbing Design, and Installation 3
ユーザ名非公開 · 96問 · 13日前Sanitation, Plumbing Design, and Installation 3
Sanitation, Plumbing Design, and Installation 3
96問 • 13日前Plumbing Code 3
Plumbing Code 3
ユーザ名非公開 · 100問 · 13日前Plumbing Code 3
Plumbing Code 3
100問 • 13日前Plumbing Code 6
Plumbing Code 6
ユーザ名非公開 · 100問 · 13日前Plumbing Code 6
Plumbing Code 6
100問 • 13日前Plumbing Code 5
Plumbing Code 5
ユーザ名非公開 · 100問 · 13日前Plumbing Code 5
Plumbing Code 5
100問 • 13日前Plumbing Code 4
Plumbing Code 4
ユーザ名非公開 · 100問 · 13日前Plumbing Code 4
Plumbing Code 4
100問 • 13日前Group 3
Group 3
Bymbasuren · 60問 · 15日前Group 3
Group 3
60問 • 15日前competence 2
competence 2
ユーザ名非公開 · 76問 · 1ヶ月前competence 2
competence 2
76問 • 1ヶ月前問題一覧
1
Avoid dropping into water as this shall short circuit the batteries
2
Is a triple frequency transmitter
3
When a rescue party is seen or heard
4
Unscrew the base and disconnect the wire harness
5
Is a manually activated transmitter
6
During a crash landing or a ditching
7
During a ditching ELT should be tied on to the raft diagonally opposite the sea anchor
8
For both above situations
9
Ensure the red light is flashing every 4 - 6 seconds
10
Inflate only one chamber during phase 2
11
Is a polished steel plate with an opening in the center for signaling
12
Push the safety catch down and squeeze both levers together
13
Hand activated freshwater maker with a suction and pump action
14
Has a water activated battery and would last for 8 hours once activated
15
At the door sill prior to boarding raft by pulling the activation tabs
16
Ensure face is free of make-up / Neck seal is airtight / Activate PBE
17
Inflate cot, Wrap the infant in a blanket and secure with the restraining straps
18
The toggle switch should be in the OFF position
19
Push the center tube down, hold down wind, unscrew cap and pull chain to activate
20
Oxygen flow will start automatically once worn
21
The green disc is visible and security seal intact
22
The loop has to be passed through the belt on to the side without the airbag
23
Ensure the red disc marked "FULL" is intact
24
Flip safety catch up and squeeze palm lever
25
ADT 406 AP - Transmission commences 30 seconds after activation
26
CCMs shall smother minor fires and grasp hot or burning parts
27
Flip the safety catch up, aim at the base of the fire and squeeze the palm lever
28
Immediately dip the flare in water to cool and dispose
29
The mask shall be fitted to the high outlet and the tubing shall not be damaged
30
Shall be used on all classes of fires safely and effectively
31
The Foil bag does not touch the viewing window
32
20
33
Tie the ELT onto the lifeline and throw into the water for activation
34
Is a manually activated transmitter and civil & military frequencies shall last for 60 hrs