1
Cleanouts shall be installed every ___ or less
100ft
2
The primary or principal artery to which branches are connected.
Main
3
Nail plate much be installed when pipe in within ___ of edge
1 1/2in
4
12.Clearance of 18 inches or more must be provided for rodding of 6 inch and smaller. Must provide 36 inches for 8 inch or larger.
Study
5
Small copper going horizontal much be supported every?
6ft
6
Trap seals shall be
2 to 4 inches
7
A pipe that conveys only waste.
Waste pipe
8
The pressure in vents should be the same as outside air
True
9
Distance from trap to vent is set by chart
Trap are length
10
Where vents pass thought the roof, the juncture must be made water tight with..?
Flashing
11
A single vent serving as the vent for two fixture drains.
Common vent
12
CPVC 1” or less must be supported every ___ going horizontal
3ft
13
Interceptors and separators must be provided
To prevent from damaging the drainage system
14
A change involving extension, addition or change to arrangement, type or purpose of installation.
Alteration
15
Vents are sized by ___ served and developed length. To go longer the size must be increased
Dfu
16
Water closets for public and employee use shall be elongated type.Water closets for public and employee use shall be elongated type.
True
17
water over 140 degrees will?
Get soft
18
heat required to raise 1 pound of water 1°F.
BTU
19
what side much hot water be on?
Left
20
all water valves must have?
Access
21
How many vents should terminate through the out door?
1
22
Lp is
Liquid
23
PVB
High hazard and siphonage
24
what is the slop if the pipe for 4in?
1/8
25
Natural gas is
Dry
26
Total fall of a trap arm shall not be more than the diameter of the trap arm.
True
27
A vent connecting to a drainage branch and venting two to eight traps in a battery.A vent connecting to a drainage branch and venting two to eight traps in a battery.
Circuit vent
28
Single wall vent is approved only with ___ of clearance from combustible material and not concealed.
6 inches
29
The drainage piping that conveys waste from the building drain to the public sewer or disposal system.
Building sewer
30
Large copper tubing much be supported every ?
10ft
31
Air gap, reduced pressure principle, double check, pressure vacuum breaker, atmospheric vacuum breaker, hose bibb vacuum breaker.
Backflow prevention
32
PVC/ABS must be supported every __ going horizontal?
4ft
33
A general term for any vertical pipe that extends at least one story.
Stack
34
Air provided to replace exhausted air
Air makeup
35
All plumbing fixtures can be rough and hard
False
36
AVB
Low hazards and siphonage only
37
Do Chemical waste must be completely separated from the sanitary drainage system.
Yes
38
Waste not requiring separation or treatment shall not be discharged into an
Interceptor
39
Horizontal trap distance shall not exceed more than
30 inches
40
CPVC larger must be supported every ___ going horizontal
4ft
41
Vertical and horizontal wet venting is permitted on the same floor level within a bathroom group.
True