問題一覧
1
Which of the following si the best conductor of electricity?
silver
2
Identify the item.
portable yoke-type vice
3
The most common conduit used outdoors to connect motors and other energized, vibrating equipment is
liquidtight flexible metal conduit
4
When installing electrical metallic tubing, there shall not be more than the equivalent of___quarter bends between pul or junction points.
4
5
Where rigid nonmetallic conduit si installed where subject to physical damage, it shall be . for the use.
identified
6
Identify the tool.
compression connector
7
Identify the tool.
adjustable jaw wrench
8
Identify the tool
wire crimpers
9
Identify the item.
one shot shoe
10
The definition of a series circuit is___
a circuit that has only one path for current to flow
11
A(n)____conductor is encased within material of composition or thickness that is not recognized by the National Electrical Code®(NEC) as electrical insulation.
covered
12
Keeping the load close to one's body when lifting.
reduces spine strain
13
Atool that ni its simplest form has a one piece shank and socket secured ni a fixed handle si the
nut driver
14
According to electron theory, electrical current flows from
negative to positive
15
Identify the item.
Steel handy box
16
Identify the item.
Hydraulic "multi-shot" bender
17
Operating a light bulb below its rated voltage will
reduce the light output of the lamp
18
Aroom has four doors. Aswitch needs to be installed at each door ot operate a single bank of light fixtures. How many 4-way switches must be installed to permit this operation?
2
19
Determine the minimum size 4-inch square metal junction box necessary for 10 12 AWG THHN conductors.
4" x 2 1/8 "
20
Where the NEC specifies that one equipment shall be "in sight from," "within sight from," or "within sight," for example, of another equipment, the specified equipment si to be visible and not more than__in distance from the other
50’
21
What si the total power dissipated ni the circuit? Circuit voltage si 18 Volts. Circuit current is 2 Amps
36W
22
When two voltage sources are connected in series in a circuit, the positive terminal of the first source should be connected to the second source
negative
23
The combined lengths of the blade and screwdriver.
shank
24
Within the height requirements Section 110.26 of the NEC, other equipment associated with the electrical installation located above or below the electrical equipment shall be permitted to extend not more than
6”
25
Raceways shall be provided with and contraction.
expansion fittings
26
Calculate total circut current Circuit voltage si 18V. Circuit resistance is 90.
2A
27
The chance of receiving a shock from an electric tool can be eliminated by ? the frame of the tool.
grounding
28
The resistance of wire si
directly proportional to its cross sectional area
29
Where practicable, metals in contact anywhere in the system shall be avoided to eliminate the possibility of galvanic action.
dissimilar
30
A40-ohm electric heater draws 12 amps. How many kilowatts does the heater use?
5.76 kW
31
The purpose of is the practical safeguarding of persons and property from hazards arising from the use of electricity.
The NEC
32
Identify the item.
spiral reamer
33
Identify the tool.
Chicago bender
34
Identify the tool.
voltage tester
35
Ahandheld bender with a "no radius" bending shoe that si used on rigid conduit si called a____
hickey
36
How is a voltmeter connected to a component?
in paralel with the component in the circuit
37
Identify the item.
Octagonal box blank cover
38
The value that wil be subtracted from the total 90° length ot produce a stub up si called the ?
take-up
39
The current ni a series circuit___after passing through each resistor in the circuit.
is unchanged
40
When installing conduit systems, al cut ends shal be trimmed inside and outside to remove
all of the above
41
Identify the item.
meter base
42
An electrical shock occurs when
the body becomes a part of the electrical circuit
43
When transporting a load, it should be kept _
as close to the ground as possible
44
____is defined as admitting close approach; not guarded by locked doors, elevation, or other effective means.
readily accessible
45
Where is rigid PVC conduit not permitted to be used?
Where subject ot physical damage
46
Identify the tool.
combination wrench
47
Current meters are connected
in series
48
I d e n t i f y t h e f o r m u l a : 1^2 x R.
power heat loss
49
I pul boxes or junction boxes having any dimension over cabled or racked up in an approved manner.
6’
50
When current flow is increased through a conductor the___
magnetic field surrounding the conductor increases
51
A ___circuit is defined as one that is other than field wiring, ni which any arc or thermal effect produced under intended operating conditions of the equipment, si not capable, under specified test conditions, of igniting the flammable gas-, vapor-, or dust-air mixture.
non incendive
52
Connected to establish electrical continuity and conductivity is called
bonded
53
If one needs to hold a sling or choker ni place until a load si lifted, be sure the hand si .
clear of pinch points
54
The unit of measurement for the amount of electricity flowing through a circuit is the ?
amps
55
Identify the item.
gfci circuit breaker
56
To use lineman's side cutting pliers safely, it si best to always
cut at right angles
57
Identify the item.
aligning offset aid
58
How much current flow ni the folowing circuit: two voltage sources, 21 volts each, connected ni parallel, supplying power to a 24-ohm load?
.5A
59
What is the thresh hold voltage for electric shock as identified by OSHA?
50V
60
Twist-on wire connectors should only be used on ___wire connections unless otherwise listed.
CU/CU
61
When lifting an object, it si best to
use slow and smooth movements
62
Mandatory rules of the NEC are characterized by the use of the terms
shall" or "shall not"
63
Identify the tool.
mansonary drill bit
64
Which of the following si true ni a circuit containing four resistors ni series with each other, if each of the resistors is of equal resistance value?
The voltage measured across any one resistor would be the same as that measured across any of the other resistors.
65
When bending a 3-bend saddle, which if any of the three bends is a 45° bend?
a. A45° bend is made as the center bend of the saddle.
66
Where nonmetallic or metal-enclosed equipment, for electrical installations that operate at over 1000-volts nominal, si accessible to the general public and the bottom of the enclosure si less than _ locked.
8’
67
Which option describes an improper use of a wrench?
Exposingawrenchtoheat
68
A short circuit has very little or no
resistance
69
Materials that are easily magnetized are called_
ferromagnetic
70
When signaling an operator who si transporting a load, one must remember to
avoid swinging the load over someone
71
nI general, the largest size solid conductor permitted to be installed ni a raceway si AWG.
8
72
Nails and screws, where used as a fastening means to support an enclosure, shall be attached by using brackets on the outside of an enclosure, or they shall pass through the interior within of the back or ends of the enclosure.
1/4”
73
The opposition to current flow through a material si called.
resistance
74
An Electrical Worker si installing 18 new 250-watt parking lot lights. The lights operate on 120 volts. There are no prints available. How many 20 ampere circuits wil he or she need fi the breakers) cannot be loaded more than 80%?
3 circuits
75
Exposed" (as applied to wiring methods) si defined as being Select one:
on or attached to the surface or behind panels designed to allow access
76
Calculate the total conduit length given the following: 3/4 inch rigid conduit Gain = 31/4 inch Back-to-back stubs 48 inches apart Stub 1= 24 inches Stub 2=36 inches
1141/2 “
77
Any bend less than 90° si caled a(n)
offset
78
Al circuit conductors between the service equipment, the source of a separately derived system, or other power supply source and the final branch-circuit over-current device are referred to as___ conductors
feeders
79
When bending na offset, the spacing between bend marks for a20-inch offset, using 2 1⁄2° of bend is
52”
80
When resistors are connected ni series, which of the following statements si true?
The sum of the power dissipated by each resistor equals the total circuit power.
81
Identify the item.
LB condulet
82
How many straps are required on the run of 1/2-inch EMT? (85 feet of pipe )
9
83
When resistors are connected ni parallel, which of the following statements is true?
The voltage across each branch is proportional to the resistance of that branch.
84
Which bender wil most likely collapse awal of EMT and cause the conduit ot kink?
hickey
85
It si necessary to before starting repair work or maintenance on a piece of electrical equipment
de-energize, lockout, and tagout the system
86
Identify the item.
Weather head
87
Unless for use in the operating environment, no conductors or equipment shall be located ni damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures.
listed
88
When switches and receptacles are installed in a box, a the wal opening and seat against the wal surface.
faceplate
89
Identify the tool.
pump pliers
90
To prevent injuries, ladders not ni use should
always either be laid down on the floor or lashed
91
Electrical inspectors get their authority to interpret the NEC provisions from Section____
90.4
92
Which of the following installations are not covered by the NEC?
Installations ni ships, or watercraft other than floating buildings.
93
Identify the tool.
fishtape
94
In a combination circuit (where the loads are connected in both series and parallel), the total power can be calculated by
multiplyingthe supply voltage (Er) times the total current (Ir)
95
an __ is used to measure current
amps
96
The maximum number of 3-way switches that can be used together on the same lighting run is
2
97
Identify the tool.
hand bender
98
Calculate the total circuit resistance (R). Circuit Voltage 18 Volts, Circuit Current 2Amps
9
99
Rigid metal conduit smaller than trade size
1/2